BLOG · GUIDE ·

Buy a server with 2× NVIDIA RTX PRO 6000 Blackwell Server Edition in Europe

Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software

IN BRIEF
  • Our entry server has two NVIDIA RTX PRO 6000 Blackwell Server Edition cards with 96 GB each, two AMD EPYC processors, 384 GB of DDR5 ECC memory and two NVMe drives, built to order for a first production service or a department
  • By our estimate the server draws about 1.8 kW at the wall with the cards at 600 W, so one 230 V 16 A feed per side carries it, with or without the 450 W cap
  • The main choice at order time is the chassis: a 2U server for two cards, or a chassis, power supplies and memory layout that take four cards later
  • The operating system, NVIDIA driver, CUDA and a container runtime are installed on request; NVIDIA AI Enterprise and vGPU licences come on the same invoice as the hardware
  • Every server is assembled and tested before delivery, delivered anywhere in the EU on one EU contract and invoice, with manufacturer warranty on every component handled through us; quantities and lead time are confirmed in writing with the quote

Supplied by Eurokommerz: AI servers, built to order  Request a configuration →

The entry server with two Server Edition cards

You can buy a server with two NVIDIA RTX PRO 6000 Blackwell Server Edition cards from us, built to order and delivered anywhere in the EU. It is the entry configuration among our AI servers: two 96 GB cards, two AMD EPYC processors, 384 GB of DDR5 ECC memory and two NVMe drives. Our team sizes the configuration to your workload and budget and replies within one business day.

Two cards suit a company that moves its first AI service into production: a private assistant for a few hundred staff, RAG on its own documents, or a coding assistant for a development team. The server holds gpt-oss-120b as two independent copies, Llama 3.3 70B in FP8 as one pair split over both cards, or one model per card next to an embedding model and a reranker in MIG instances. With the example values of our private ChatGPT sizing guide, two copies of gpt-oss-120b cover the peak of about 500 employees. Larger models, or many departments on one server, call for four cards; a service that must survive a host failure calls for a second server.

Parts list of the entry configuration

The table shows the reference configuration and what we change per project.

COMPONENTENTRY SERVEROPTIONS
GPUs2 × RTX PRO 6000 Blackwell Server Edition, 96 GB GDDR7 with ECC each600 W or 450 W per card
Processors2 × AMD EPYC, for example 2 × EPYC 9135 with 32 cores in totalcores from the 12 NVIDIA asks for two GPUs; Intel Xeon on request
Memory384 GB DDR5 ECC24 × 16 GB, or 12 × 32 GB to leave room for four cards
Storage2 × NVMe data-centre drivesone per socket; more drives for models and indexes
Network25 GbE for users100 to 400G for storage or a cluster
ManagementBMC with IPMI and Redfish, TPM 2.0as listed by the chassis maker
Power suppliesredundant, on A and B feedswattage and count by the chassis maker's rules
Form factor2U2U or 4U chassis listed for four cards

Our AI servers page; NVIDIA-Certified Systems configuration guide (30 September 2026) for sockets, cores, memory, NVMe, Redfish and TPM; AMD's EPYC 9135 page for cores, read on 24 October 2026.

The host follows NVIDIA's configuration guide for NVIDIA-Certified Systems: at least two sockets, six physical cores per GPU, system memory of at least twice the total GPU memory and one NVMe drive per socket. For two 96 GB cards that is 12 cores, 384 GB and two drives. Two EPYC 9135 have 16 cores and 200 W each and 12 memory channels per socket, so 24 modules of 16 GB fill every channel. Their 32 cores also cover four cards, so the processors need no change if the server grows.

The two NVMe drives hold the operating system and the model files, mirrored so that the server keeps running when one drive fails. A store for several checkpoints of 60 to 170 GB, a RAG index or local logs calls for more drives in the free bays of the chassis. For users, 25 GbE carries chat traffic; 100 GbE pays off when models load from shared storage or the server later joins a second one behind a load balancer.

Options we change per project

Most of the variants come down to whether the server stays at two cards.

  • 2U for two cards. The smallest version. Dell's PowerEdge R7725, for example, takes two cards in 2U, at 450 W each according to Dell's specification sheet. A chassis like this stays at two.
  • A chassis for four. HPE's ProLiant DL385 Gen11 takes four cards at 600 W in 2U with its Maximum Performance fan kit, and HPE's DL380a Gen12 uses the same five power supplies for two or four double-width GPUs. Starting there costs more on day one and avoids a second server later, as our guide to adding GPUs to a server later explains.
  • Memory for growth. Four cards need 768 GB by NVIDIA's rule. Twelve modules of 32 GB give the same 384 GB with half the channels free for the later step, at half the memory bandwidth until then.
  • Power mode. With two cards the 450 W cap is not needed for the power feed. It lowers heat and is the rated mode in some 2U servers, at a cost of 2 to 9 per cent of throughput that StorageReview measured on the RTX PRO 6000 Workstation Edition.
  • One processor. Single-socket 2U servers for two cards exist, but NVIDIA's current guide asks for two sockets, so our entry configuration uses two.
  • Max-Q instead of Server Edition. The RTX PRO 6000 Max-Q is the workstation card, a 300 W blower card that NVIDIA supports up to four per workstation. In a rack server it belongs only in a chassis whose maker lists it, and many server makers do not; for continuous operation in a rack we recommend the Server Edition. For a desk-side system, see our page to buy a workstation with two RTX PRO 6000 Max-Q.

Models and conversations on two cards

By our users-per-card rule, 0.9 × 95.6 GiB − 3 GiB per card, the two cards hold 166.1 GiB of weights and KV cache. The table gives four examples; our guide to what a 2× RTX PRO 6000 Server Edition server runs has every layout, published results and the arithmetic.

MODELCONTEXTLAYOUTCONVERSATIONS
Llama 3.3 70B, FP88Ktwo copies24
Llama 3.3 70B, FP88Kone TP=2 pair78
gpt-oss-120b32Ktwo copies38
Qwen3.8-27B, FP832Ktwo copies50; 94 with FP8 cache

Our estimates by the users-per-card rule: concurrent conversations at full context length, FP8 KV cache for Llama 3.3 70B, 16-bit for the others.

MIG gives the cards a second use. One card serves the main model whole while the other is split into four 24 GB instances for an embedding model, a reranker, speech-to-text and a small task model, each isolated from the others. A model split over both cards runs on whole cards, because NVIDIA's MIG guide states that NCCL is not supported with MIG; our RTX PRO 6000 MIG profiles show what fits in each size.

The figures count requests in flight at the same moment, which a gateway log shows at the busiest hour. We build this server in every variant above; send us your models and peak requests, and our team returns a configuration with the conversations per layout.

Rack, feed and air for about 1.8 kW

By our estimate, two cards at 600 W and two 200 W processors need about 1.8 kW at the wall, and about 1.5 kW with the cards at 450 W; the 15 per cent we add for memory, drives, fans and conversion losses is an assumption that a measurement on the delivered system confirms or replaces. We plan a 230 V 16 A single-phase feed at 80 per cent, which is 2.94 kW, so the server fits one such feed per side. With redundant power supplies on an A and a B feed, each side carries the whole server.

  • Outlets. The power supplies decide the cord. HPE, for example, allows only C19 or C19-C20 cords for the 2,400 and 3,200 W supplies its DL380a Gen12 needs with this card, so check that the rack PDU has the matching outlets.
  • Cooling. About 1.8 kW of heat needs roughly 290 CFM of air at an 11 °C rise, by the 160 CFM per kW in our guide to GPU rack power and cooling. NVIDIA's product brief asks for 43 CFM through each card's heat sink at a 25 °C inlet and 125 CFM at 45 °C.
  • Room. Under full load the server belongs in a rack in a server room or data centre; our guide to a GPU server in an office covers the cases in between.
  • Growth. Four cards at 600 W would need about 3.2 kW with the same processors, more than one 16 A feed; at the 450 W cap about 2.5 kW.

We check the rack position before we quote. Tell us the feed type, the A/B requirement and the inlet temperature, and we choose the chassis and power supplies to match.

Operating system, driver and licences on delivery

On request the server arrives with the operating system, NVIDIA driver, CUDA and a container runtime installed, so your team can start a serving engine on the first day.

LAYERWHAT WE INSTALLNOTE
Operating systema Linux release the chassis maker supportsor your own image
NVIDIA driverthe branch you will run in productionR575 or later for this card
CUDAmatching the driver12.9 or later on x86
Containerscontainer runtime with NVIDIA Container Toolkitfor vLLM, SGLang or NIM images
GPU layoutMIG instances, if you plan themup to four per card
LicencesNVIDIA AI Enterprise, vGPUon the same invoice

Our AI servers page; driver and CUDA minimums from NVIDIA's product brief SP-12355-001_v02 for the Server Edition.

As of October 2026, R580 is NVIDIA's long-term branch with support to June 2028, and NVIDIA's security bulletin of 30 September 2026 names 580.178.04 as the first fixed R580 driver; our article on NVIDIA driver branches and CUDA versions explains the choice. Serving on bare metal with open-source engines needs no NVIDIA licence. NVIDIA AI Enterprise, licensed per GPU, is needed for NIM and for compute vGPU profiles; on vSphere the card needs ESXi 8.0 Update 3g or later.

From enquiry to delivery in the EU

The steps are the same for one server or a pair of them for failover.

  1. You describe the workload: models, users, data, rack and timeline. Sizing is free of charge.
  2. We propose the configuration and check that cards, chassis, power supplies and cooling fit your rack and feed.
  3. You receive a written quote within one business day, with price and warranty terms per component; quantities and lead time are confirmed in writing with it.
  4. You order on one EU contract with an EU invoice from Eurokommerz in Vienna; NVIDIA licences are lines on the same invoice.
  5. We assemble the server and test it before delivery, with a power-on and basic load test.
  6. We deliver anywhere in the EU, with commissioning on site on request; other destinations on request through our logistics partner.
  7. Every component carries the manufacturer warranty, handled through us; DOA units are replaced, and the assembly is covered by us.

We also build in your own chassis or with parts you already own, after a compatibility check of the platform, power and cooling. For your own acceptance test on arrival, our GPU server acceptance testing guide lists the checks, and our GPU server quote comparison shows what each line of a quote should state.

Details that make the first quote exact

A few sentences are enough to start. These points let us quote the exact configuration in the first reply.

  • The models you plan to run, with quantisation and the context length you will declare
  • Peak requests in flight, or the number of users and how they work
  • Whether the server should take four cards later, and when
  • Other workloads on the same server: embedding and reranking, speech-to-text, virtual machines or MIG
  • Software platform: bare metal, Kubernetes or vSphere, with the version
  • Rack position: free height units, feed type and current, A/B feeds, PDU outlets and inlet temperature
  • Delivery site, invoicing entity, timeline and any tender requirements, which our GPU server tender specification helps to word

Two servers are often the better first order when the assistant must stay up during maintenance, as our guide to LLM high availability on two GPU nodes explains.

Cards, servers and licences from one supplier

We supply the server with two NVIDIA RTX PRO 6000 Blackwell Server Edition cards in 2U or in a chassis for four, together with four-card and eight-card versions, and the RTX PRO 6000 cards on their own for servers you already run. NVIDIA AI Enterprise and vGPU licences come on the same EU contract and invoice as the hardware. The four-card version is on our page to buy a 4× RTX PRO 6000 Server Edition server.

FAQ

Where can I buy a server with two RTX PRO 6000 Server Edition cards in Europe?
From us: we build servers with two NVIDIA RTX PRO 6000 Blackwell Server Edition cards to order and deliver them anywhere in the EU, on one EU contract and invoice with manufacturer warranty on every component. Send us the workload and the rack position, and we reply with a configuration and a written quote within one business day.
How much does a 2× RTX PRO 6000 Server Edition server cost?
We quote the exact configuration in writing. The price depends on the chassis and whether it takes four cards later, the processors, the amount of memory, the drives and network cards, the NVIDIA licences you need and the warranty terms. Send us the workload and we reply with a written quote within one business day.
What are the specs of a server with two RTX PRO 6000 Server Edition?
Our entry server has two RTX PRO 6000 Blackwell Server Edition cards with 96 GB of GDDR7 each, 192 GB in total, two AMD EPYC processors, 384 GB of DDR5 ECC memory, two NVMe drives, redundant power supplies and a BMC for out-of-band management, usually in 2U.
How many users does a server with two RTX PRO 6000 Server Edition cards serve?
By our users-per-card rule, Llama 3.3 70B in FP8 at 8K holds 24 concurrent conversations as two copies and 78 as one tensor-parallel pair, with an FP8 KV cache; gpt-oss-120b holds 38 conversations of 32K as two copies. With the example values of our sizing guide, that covers the peak of about 500 employees.
How much power does a 2× RTX PRO 6000 Server Edition server need?
By our estimate about 1.8 kW at the wall with the cards at 600 W and about 1.5 kW at the 450 W cap, with two 200 W processors. That fits one 230 V 16 A feed per side, planned at 80 per cent, and with A and B feeds each side carries the whole load.
Can we start with two RTX PRO 6000 Server Edition and add two cards later?
Yes, in a chassis listed for four cards with power supplies, cables and a memory layout chosen for four. Four cards need 768 GB of system memory and, at 600 W, a 32 A or three-phase feed; at the 450 W cap they stay on 16 A. Tell us at the quote stage.
Can the server use RTX PRO 6000 Max-Q cards instead?
Only in a chassis whose maker lists the Max-Q. It is a 300 W workstation card with a blower, and many server makers do not list it for their GPU servers. For continuous operation in a rack we recommend the RTX PRO 6000 Server Edition, which is passive and designed for server airflow.

We build servers with two RTX PRO 6000 Server Edition cards to order, ready for four if you need it, and deliver them across the EU. Describe your task in a few sentences and our team will help. We reply within one business day.