RTX PRO 6000 Server Edition compatible servers, and adding it to an existing one
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- The RTX PRO 6000 Blackwell Server Edition is a passive, dual-slot, full-length PCIe Gen5 card of 300 to 600 W, so it runs only in a server whose manufacturer lists it for that model, slot, power cable and fan set
- As of 9 October 2026 the manufacturers list it in the Dell PowerEdge XE7745 (up to 8), the HPE ProLiant Compute DL380a Gen12 (up to 8) and DL385 Gen11 (4), and the Lenovo ThinkSystem SR650a V4 (2, or 4 capped at 450 W) and SR675 V3 (8); NVIDIA names the Dell R7725 with two cards, which Dell’s sheet rates at 450 W each
- Cisco’s UCS C845A M8 takes 2, 4, 6 or 8 cards, Supermicro’s 4U RTX PRO Server SYS-422GL-NR and its 4U SYS-422GA-NRT take up to 8, and NVIDIA states that its RTX PRO Servers, with up to eight cards, are NVIDIA-Certified
- Four cards at 600 W fit the 2U HPE DL385 Gen11 and the Cisco UCS C845A M8; with processors, a four-card server at 600 W per card needs about 3.4 kW or more at the wall by our estimate, above the 2.94 kW we plan per 230 V 16 A feed
- Dell lists the card in seventeenth-generation PowerEdge servers only, and Lenovo supports it on the SR650a V4 but not on the SR650 V4, so a server one generation older or a sibling model is not on the list
- Lenovo ships the card without power cables, which are server-specific and ordered separately for a field upgrade; HPE requires 2,400 W or 3,200 W power supplies whenever the card is configured in a DL380a Gen12
Supplied by Eurokommerz: AI servers, built to order Request a configuration →
Which servers support the RTX PRO 6000 Server Edition
The RTX PRO 6000 Blackwell Server Edition is a passively cooled, dual-slot, full-height, full-length PCIe Gen5 card with a power limit configurable from 300 to 600 W (NVIDIA product brief SP-12355-001_v02, 27 June 2025), so it runs only in a server whose manufacturer has qualified it for that model, slot, power cable and fan set. As of 9 October 2026, the compatible servers named in the manufacturers’ own documents or by NVIDIA are the Dell PowerEdge XE7745 and R7725, the HPE ProLiant Compute DL380a Gen12, ProLiant Compute DL380 Gen12 and ProLiant DL385 Gen11, the Lenovo ThinkSystem SR650a V4 and SR675 V3, the Cisco UCS C845A M8 and the Supermicro SYS-422GL-NR. Dell’s XE7740 and Supermicro’s SYS-422GA-NRT, SYS-322GA-NR and SYS-522GA-NRT complete the list in documents we read on 24 October 2026. Documents read on 12 November 2026 add the HPE ProLiant Compute DL345 Gen12 and servers from Gigabyte and ASUS, listed in their own section below. The maximum ranges from two to eight cards per server, depending on the model. For any server, check the manufacturer’s GPU support list for the exact model first; a free x16 slot alone does not qualify it.
We supply the card for servers you already run and in AI servers built to order; send us the server model, its configuration and the number of cards, and we reply within one business day with a written quote for the cards or for a server with them.
NVIDIA’s family comparison lists the card with passive cooling, 96 GB of GDDR7 with ECC and a PCIe Gen 5 x16 interface, and it takes its air from the server’s fans. The product brief, SP-12355-001_v02, gives two power modes, 600 W and 450 W maximum, each with a 300 W minimum. A server maker can allow less: Dell’s datasheet for its AI Factory nodes with the card gives the TDP as “configurable between 450W & 600W”, and Dell’s technical guide states that the XE7745 “does not support user power cap”. The range in the brief belongs to the card, not to every server. NVIDIA also lists a liquid-cooled, single-slot version for its 6U MGX design; this article covers the air-cooled card. How it differs from the Workstation and Max-Q editions is set out in our comparison of the three RTX PRO 6000 editions.
Cards per server, by manufacturer
Each model below is named for the card by its manufacturer, or by NVIDIA, in a document we read on 9 or 24 October 2026.
| SERVER | FORM FACTOR | CARDS PER SERVER | SOURCE |
|---|---|---|---|
| Dell PowerEdge XE7745 | 4U, two AMD EPYC 9005 | up to 8 at 600 W | Dell spec sheet, July 2025; technical guide Rev. A09 |
| Dell PowerEdge XE7740 | 4U, two Intel Xeon 6 | up to 8, per Dell’s AI Factory datasheet | Dell datasheet; XE7740 technical guide Rev. A04 |
| Dell PowerEdge R7725 | 2U | 2, at 450 W per Dell | NVIDIA, 11 August 2025; Dell sheet |
| HPE DL380a Gen12 | 4U | up to 8 | HPE DL380a Gen12 QuickSpecs |
| HPE DL380 Gen12 | 2U | see platform QuickSpecs | NVIDIA Accelerators for HPE QuickSpecs |
| HPE DL385 Gen11 | 2U | 4 | HPE DL385 Gen11 QuickSpecs |
| HPE DL345 Gen12 | 2U, one AMD EPYC | see platform QuickSpecs | NVIDIA Accelerators for HPE QuickSpecs, version 84 |
| Lenovo ThinkSystem SR650a V4 | 2U | 2 at 600 W, 4 capped at 450 W | Lenovo Press LP2263 |
| Lenovo ThinkSystem SR675 V3 | 3U | 8, with 5th Gen AMD EPYC only | Lenovo Press LP2263 |
| Cisco UCS C845A M8 | 4RU, two AMD EPYC | 2, 4, 6 or 8 | Cisco data sheet, 24 August 2026 |
| Supermicro SYS-422GL-NR | 4U MGX, two Xeon 6900 | up to 8 | Supermicro product page |
| Supermicro SYS-422GA-NRT | 4U, two Xeon 6900, dual-root PCIe switches | up to 8 at 600 W | Supermicro datasheet |
| Supermicro SYS-322GA-NR | 3U, two Xeon 6900 | up to 8 double-width GPUs; Server Edition named, no count per card | Supermicro product page, read 12 November 2026 |
| Supermicro SYS-522GA-NRT | 5U | 8 | Supermicro RTX PRO 6000 page |
Read on 9 October 2026: Dell PowerEdge Server GPU Matrix (August 2026), XE7745 (July 2025) and R7725 (December 2025) specification sheets; NVIDIA press release of 11 August 2025; NVIDIA Accelerators for HPE QuickSpecs (version 83, 8 September 2026) and the DL380a Gen12 and DL385 Gen11 QuickSpecs; Lenovo Press LP2263 (28 July 2026); Cisco UCS C845A M8 data sheet (24 August 2026); Supermicro PCIe GPU systems and SYS-422GL-NR pages. Read on 24 October 2026: Dell XE7740 Technical Guide Rev. A04 and XE7745 Technical Guide Rev. A09, Dell AI Factory with RTX PRO 6000 datasheet, Supermicro SYS-422GA-NRT and SYS-322GA-NR datasheets and RTX PRO 6000 systems page. Read on 12 November 2026: Dell PowerEdge Server GPU Matrix (October 2026), NVIDIA Accelerators for HPE QuickSpecs (version 84) and the Supermicro SYS-322GA-NR product page. Counts are maximums; the configurator decides per configuration. For four cards at 600 W, HPE lists four for the 2U DL385 Gen11 and Cisco offers four in the UCS C845A M8. HPE’s DL380a Gen12 takes two, four or eight of the cards, with five power supplies for two or four and eight for eight. The Dell XE7745 and Supermicro’s SYS-422GL-NR and SYS-422GA-NRT state only a maximum, so ask the manufacturer whether four is an orderable configuration and which slots and fans it uses; Supermicro’s product page for the 3U SYS-322GA-NR, read 12 November 2026, names the Server Edition and gives “Up to 8 double-width or 16 single-width GPUs” without a count per card, with three power supplies in a 2+1 layout; have Supermicro confirm the number of 600 W cards for this model. Lenovo’s SR650a V4 takes four only in the version capped at 450 W. We supply servers from Supermicro, Gigabyte, ASUS, Dell, HPE, Lenovo, Cisco and other makers per project.
Dell’s PowerEdge Server GPU Matrix, dated October 2026 and read 12 November 2026, lists the card as “RTX Pro 6000 BSE” in its seventeenth-generation table, where it is ticked for five platforms, and in neither the fifteenth nor the sixteenth-generation table, so a sixteenth-generation server such as an R760xa is not on Dell’s list. Check the column for your exact model in the matrix itself; Dell notes that the maximum can differ between configurations of the same platform. The XE7745 specification sheet names the card as an example of the “up to 8 double-wide 600W PCIe AI accelerators” the server takes. NVIDIA’s announcement of 11 August 2025 names “Dell PowerEdge R7725 2U servers featuring two RTX PRO 6000 GPUs”, while Dell’s R7725 specification sheet of December 2025 gives the GPU options as “Up to 2 x 450W DW”. Confirm the power per slot with Dell before you plan on 600 W. Dell has also published a benchmark result with eight cards at 600 W in its Intel-based PowerEdge XE7740, cited in our comparison with the H200 NVL, and Dell’s datasheet for its AI Factory with the card lists the XE7740 next to the XE7745, with up to eight cards per node; the XE7740 technical guide (Rev. A04, April 2026) gives their thermal limits.
HPE’s NVIDIA Accelerators QuickSpecs, version 84 with a change log entry of 8 October 2026, read 12 November 2026, list the card as SKU S6A73C for the ProLiant Compute DL380a Gen12, the ProLiant Compute DL380 Gen12, the ProLiant DL385 Gen11 and the ProLiant Compute DL345 Gen12, for two edge systems and for the HPE Compute Scale-up Server 3250, and refer to the platform QuickSpecs “for configuration rules including enablement kits”. The DL380a Gen12 QuickSpecs state “RTX Pro 6000 GPU limited to max quantity of 8”, although the same document allows most other double-wide GPUs in quantities of 2, 4, 8 and 10; HPE’s ten-card benchmark system with this card is described in our article on RTX PRO 6000 benchmarks, but ten is not an orderable configuration in the QuickSpecs. They also exclude the card from the 8DW NIC FIO configuration, P75011-B21. The DL385 Gen11 QuickSpecs list “4x RTX PRO 6000 BSE” among their newly supported configurations.
Lenovo’s product guide LP2263, updated on 28 July 2026, offers the card under two feature codes, one for 600 W and one “Slot Capped at 450W”. The SR650a V4 takes two cards at 600 W or four of the capped version. The SR675 V3 takes eight, with a footnote limiting support to 5th Gen AMD EPYC processors, and every other current ThinkSystem server in the table is marked as not supported. Another footnote says “RTX PRO 6000 GPU is only supported on SR650a V4”, followed by its machine types, so the SR650 V4 without the “a” is excluded.
Cisco’s data sheet for the UCS C845A M8, updated on 24 August 2026, describes a 4RU server with two AMD Turin processors and “Two, four, six, or eight” PCIe GPUs, the RTX PRO 6000 at 600 W among them. Supermicro’s PCIe GPU systems page shows a 4U RTX PRO Server, the SYS-422GL-NR, with up to eight cards, and its product page lists the card. The same page shows a 2U RTX PRO Server for up to two cards, but the product page it links to names neither the card nor a GPU count, so confirm that model with Supermicro. Supermicro’s page for RTX PRO 6000 systems adds three models: the 4U SYS-422GA-NRT, whose datasheet states “Support up to 8 double-width 600W PCIe GPU accelerator cards at 35ºC”, with dual-root PCIe 5.0 switches and four 3,200 W supplies in a 3+1 layout; the 3U SYS-322GA-NR, whose product page, read 12 November 2026, names the RTX PRO 6000 Blackwell Server Edition and gives “Up to 8 double-width or 16 single-width GPUs” without a count per card; and the 5U SYS-522GA-NRT with eight. NVIDIA’s RTX PRO Server page names other manufacturers as well.
Gigabyte and ASUS servers that name the card
Gigabyte and ASUS publish product pages and datasheets that name the RTX PRO 6000 Blackwell Server Edition; we read them on 12 November 2026. Each maker states the card count per model and ties it to conditions, which the table gives as the maker words them.
| SERVER CLASS | MODELS | CARDS NAMED | CONDITION STATED |
|---|---|---|---|
| Gigabyte 4U RTX PRO Server | XL44-SX2-AAS1 | 8, “Configured with 8 x” | system operating range 10 to 30 °C |
| Gigabyte 6U, liquid-cooled | XLS4-SX2-LAS1 | 8 liquid-cooled cards | coolant inlet not above 45 °C |
| Gigabyte 4U G494 | G494-SB4-AAP2, G494-ZB4-AAP2 | 8, “Conditionally supports” | 25 °C ambient; optional fan kit for 600 W cards |
| Gigabyte 2U, one processor | XV23-ZU0-AAJ1, XV24-SU0-AAJ1 | 4 | 25 °C ambient |
| Gigabyte 2U G294 | G294-S42-AAP2, G294-Z42-AAP2, G294-A22-AAP2 | 4 | 25 °C ambient |
| ASUS 4U ESC8000 | ESC8000-E12, ESC8000-E12P, ESC8000A-E13, ESC8000A-E13P | named next to eight H200 cards; eight slots of up to 600 W | 10 to 35 °C with a note above 30 °C (datasheets of E12, E12P, E13) |
| ASUS 4U RTX PRO Server | ESC8000A-E13X | 8 | 10 to 35 °C with the same note |
Gigabyte product pages and datasheets (G494-SB4-AAP2 datasheet last updated 20 July 2026, XL44-SX2-AAS1 datasheet 21 July 2026) and ASUS product pages and datasheets (undated), read 12 November 2026.
Gigabyte’s server business is Giga Computing. For the two 4U G494 models, the product pages list eight cards under “Conditionally supports”, at 25 °C ambient, and state that 600 W cards need an optional fan kit; with the kit the chassis is 1,000.5 mm deep instead of 880 mm. Gigabyte names four cards at 25 °C ambient for its 2U models, the three G294 models among them, although these have eight double-width slots. The XL44-SX2-AAS1, which Gigabyte calls an NVIDIA RTX PRO Server, is described as configured with eight cards. Our article on Gigabyte servers for the RTX PRO 6000 Server Edition goes through the models by card count. ASUS names the card from the ESC8000-E12 and ESC8000-E12P (Intel Xeon 6) and the ESC8000A-E13, ESC8000A-E13P and ESC8000A-E13X (AMD EPYC) on. The pages of the older ESC8000-E11P and ESC8000A-E12 do not name it, and the datasheets of the 2U models ESC4000A-E12 and ESC4000-E11 are written for the Max-Q edition of the card. On the E12, E12P, E13 and E13P pages the card stands next to eight dual-slot H200 cards without a count of its own; the ESC8000A-E13X page states eight RTX PRO 6000 Blackwell Server Edition cards. The datasheets we could open (E12, E12P, E13 and E13X) give an operating range of 10 to 35 °C and ask buyers to contact the ASUS sales representative for operating temperatures above 30 °C. The details are in ASUS ESC8000 servers for the RTX PRO 6000 Server Edition. Three further articles set the makers’ documents side by side: Supermicro, Gigabyte and ASUS servers for eight GPUs, Dell PowerEdge XE servers for the H200 NVL and HGX B300 and GPU support of HPE ProLiant servers by model.
NVIDIA RTX PRO Servers and NVIDIA-Certified Systems
NVIDIA calls an RTX PRO Server a “Universal data center platform for enterprise AI and industrial AI”, built by system partners on its MGX reference designs. Its RTX PRO Server page, updated on 11 June 2026, lists “8x RTX PRO 6000 Blackwell Server Edition PCIe GPUs” in the quick specifications. It shows two cards in a 2U design and eight in the 4U and 6U designs, both with “NVIDIA ConnectX-8 SuperNICs with PCIe Gen 6 switch”; the 6U design uses the liquid-cooled card. A second 2U design holds eight RTX PRO 4500 Blackwell Server Edition cards, a single-slot card of 165 W with 32 GB. The page states that “RTX PRO Servers are NVIDIA-Certified”.
NVIDIA’s reference architecture for the RTX PRO AI Factory, updated on 18 May 2026, gives the server components behind that design. It specifies up to eight cards, four BlueField-3 SuperNICs per server at up to 400 Gbps and one BlueField-3 DPU for north-south traffic. Per GPU, it asks for at least one Gen5 x16 link, seven physical CPU cores and 128 GB of system memory, which makes 28 cores and 512 GB for a four-card server. Our article on how many GPUs fit in one server explains the lane, switch and airflow limits behind these counts and compares inlet temperature limits.
NVIDIA says NVIDIA-Certified Systems “undergo a rigorous suite of functional, security, and performance tests”, from single-GPU to multi-node, and that “Hardware support for NVIDIA-Certified Systems is available from the system vendors”. Its page of 3 September 2026 points to the Qualified System Catalog for certified partner systems; check the exact model there. Who runs the tests, what they cover and how to read NVIDIA’s list are explained in our guide to NVIDIA-Certified Systems.
For a new server, we build AI servers to order with 2 to 8 RTX PRO 6000 Server Edition cards and check the rack, power and airflow before we quote. Send us the models you plan to run, the number of cards and the power the rack position provides, and we answer with a configuration and a written quote within one business day.
Adding the card to a server you already run
A server already in the rack can take the card only if its exact model and configuration are on the manufacturer’s list.
| CHECK | WHAT TO CONFIRM | WHERE DOCUMENTED |
|---|---|---|
| Model and generation | the machine type is on the list, not just the family | Dell GPU matrix; Lenovo LP2263 footnotes; HPE accelerator QuickSpecs |
| Slots, risers, kits | permitted slots, riser and GPU enablement kit | platform QuickSpecs or product guide |
| Power cable | 16-pin cable for that server and slot | Lenovo LP2263; HPE platform QuickSpecs |
| Power per slot | 600 W, or a 450 W cap in that slot | Lenovo feature codes; Dell spec sheets |
| Power supplies | wattage and number of supplies | HPE DL380a Gen12 QuickSpecs |
| Fans and air | fan kit for 600 W GPUs, inlet limit | HPE DL385 Gen11 and DL380a Gen12 QuickSpecs; Dell thermal matrix; Supermicro product page |
| OS, hypervisor, driver | OS releases per server; for vGPU on vSphere ESXi 8.0 U3g or VCF 9.0.1 and later; driver branch | Lenovo LP2263; NVIDIA driver release notes and vGPU support matrix |
| Warranty | whose warranty covers the card | the manufacturer’s option guide |
Compiled from the manufacturer documents named under the first table, read on 9 October 2026.
The same order of checks applies to the H200 NVL, with that card’s own cable and bridge rules, in our H200 NVL checklist for an existing server, which also covers the BIOS settings for large memory windows.
Power cables, 450 W slots and power supplies
Lenovo states that “The RTX PRO 6000 Blackwell GPU option part number does not ship with auxiliary power cables” and that “Cables are server-specific due to length requirements”. For a field upgrade, in Lenovo’s words, “cables will need to be ordered separately”. Lenovo names a 320 mm 16-pin (2x6+4) cable kit, 4X97B04860, for the SR650a V4 and a 235 mm 16-pin cable, 4X97A84510, for the SR675 V3.
The card reads the power class its cable declares through the sense pins and caps itself to match. On a cable for 450 W it runs at 450 W, and the comparison of the three editions shows how that looks in nvidia-smi. The three power levels and what 450 W costs in throughput are worked out in our article on Server Edition power at 600, 450 and 300 W. Some servers set the cap on purpose: Lenovo’s second feature code is “Slot Capped at 450W” and is the version that allows four cards in the SR650a V4.
The power supplies are the next limit. HPE’s DL380a Gen12 QuickSpecs state “2400W or 3200W PSUs must be selected if H100 NVL, H200 NVL, or RTX Pro 6000 GPUs are configured”, with five power supplies for two or four double-wide GPUs, eight for eight or ten, and C19 or C19-C20 power cords only. Supermicro fits four 3,200 W supplies in a 3+1 configuration in the SYS-422GL-NR. Four cards at 600 W draw 2.4 kW and eight draw 4.8 kW before processors and fans. By our estimate, cards and processors plus 15 per cent for memory, drives, fans and conversion losses, a four-card server at 600 W per card draws about 3.4 kW at the wall with two 280 W AMD EPYC 9355, and about 3.7 kW with the 400 W processors Cisco allows in the C845A M8. Both lie above the 2.94 kW we plan for a 230 V 16 A feed, 80 per cent of its 3.68 kW, so the rack position needs 32 A or three-phase, or the cards run at the 450 W cap, about 2.7 kW with the EPYC 9355. For eight cards at 600 W, Dell’s XE7745 technical guide supports A/B grid redundancy only with its 3,200 W supplies, which deliver that rating at 220.1 to 240 V and 2,900 W at 200 to 220 V, with C19 cords; Cisco fits up to four 3.2 kW supplies with N+1 redundancy in the C845A M8. Our guide to GPU server power on 16 A, 32 A and three-phase works out the feeds. The rack feed therefore has to be planned with the server, as our guide to GPU rack power and cooling explains; CPU, RAM and storage for a 4-GPU server covers the rest of a four-card build, and eight RTX PRO 4500 or four RTX PRO 6000 compares it with more, smaller cards.
Fans, airflow and inlet temperature
A passive 600 W card depends on the server’s fan set, and the manufacturers name the fan kits that go with it. HPE’s DL385 Gen11 QuickSpecs state that the “Maximum Performance Fan kit is only supported when 600W GPUs are in the configuration”, naming the RTX PRO 6000 BSE among them. In the DL380a Gen12, eight RTX PRO 6000 cards require HPE’s Front Chassis Fan Module Kit, P79656-B21, and its Front Panel Kit, P79660-B21.
Inlet temperature limits are set per server and GPU configuration. Dell’s thermal matrix limits the XE7745 to 30 °C with the RTX PRO 6000, and Supermicro specifies an operating temperature of 10 to 35 °C for the SYS-422GL-NR. Measure the inlet temperature at the rack position before ordering and compare it with the limit for your exact configuration; a warm inlet makes the server fans run faster and the cards lower their clocks.
| SERVER | CONFIGURATION | MAX. INLET | SOURCE |
|---|---|---|---|
| Dell XE7745, 4U | 8 × Server Edition | 30 °C | technical guide Rev. A09 |
| Dell XE7740, 4U | 8 × Server Edition | 30 °C | technical guide Rev. A04 |
| Dell XE7740, 4U | 4 in the middle slots | 35 °C | technical guide Rev. A04 |
| Lenovo SR650a V4, 2U | 2 × Server Edition, or 4 at 450 W | 25 °C | Lenovo thermal rules |
| Supermicro SYS-422GA-NRT, 4U | 8 × Server Edition and 5 BlueField-3 | 35 °C | Supermicro datasheet |
| Supermicro SYS-322GA-NR, 3U | operating range of the server | 10 to 35 °C | Supermicro datasheet |
Dell PowerEdge XE7745 Technical Guide Rev. A09 (September 2026, configuration with eight E3.S NVMe drives and no rear drives) and XE7740 Technical Guide Rev. A04 (April 2026), both with HPR Platinum fans; Lenovo ThinkSystem SR650a V4 thermal rules; Supermicro SYS-422GA-NRT and SYS-322GA-NR datasheets; read on 24 October 2026. HPE’s DL380a Gen12 QuickSpecs refer to a separate HPE document for these values; for that server and the Cisco C845A M8, ask the maker for the limit of your configuration.
A server room at the top of ASHRAE’s recommended range, 27 °C at the inlet, leaves 3 °C to Dell’s 30 °C and is already above Lenovo’s 25 °C, while Supermicro’s 35 °C leaves 8 °C. Our guide to GPU server inlet temperature explains where and how to measure.
Operating system, driver and firmware
Lenovo lists supported operating systems per server; for the SR650a V4 they include Red Hat Enterprise Linux 9.7 and 10.1, SUSE Linux Enterprise Server 15 SP6, 15 SP7 and 16, and Ubuntu 22.04.5 LTS or later and 24.04 LTS or later, both with the HWE kernel.
Our guide to NVIDIA driver branches and CUDA versions sets out the software minimums for the card from NVIDIA’s documents: the open kernel modules, which NVIDIA requires for Blackwell, driver R575 and, on x86, CUDA 12.9 or later from the Server Edition’s product brief, and vGPU from release 19.0. The time-sliced and MIG-backed profiles are listed in our article on RTX PRO 6000 vGPU profiles. On VMware, NVIDIA’s vGPU support matrix of 29 September 2026 lists the card for ESXi 8.0 Update 3g (8.0 U3 P06) or later and for VMware Cloud Foundation 9.0.1 or later, so update an older ESXi host before the card is used through vGPU. As of November 2026, NVIDIA’s driver lifecycle table lists two long-term support branches, R580 (to June 2028; newest release 580.196.07 of 21 October 2026) and R620 (to September 2029; first release 620.70.06 of 4 November 2026), and NVIDIA’s security bulletin of 30 September 2026 (ID 5861, still the newest driver bulletin on 19 November 2026) names 580.178.04 as the first fixed R580 driver. Bring the server’s BIOS and management controller firmware to the level the manufacturer lists for the GPU before the card goes in. Once the card runs, the host is hardened like any other GPU server, as described in securing a GPU server.
Support and warranty for a card bought separately
The manufacturers state their position for their own option part numbers. Lenovo’s guide LP2263, updated on 28 July 2026, gives the card a “One year limited warranty” and adds that “When installed in a Lenovo server, the GPU assumes the server’s base warranty and any warranty upgrades.” NVIDIA states that hardware support for NVIDIA-Certified Systems comes from the system vendors.
On the pages we read on 9 October 2026, Dell, HPE, Cisco and Supermicro do not state support terms for a card bought outside their own option part numbers. Ask the server manufacturer before you order, and keep the cable, fan kit and drive configuration within its list. Warranty, licences and the checks before an order are in our guide to buying RTX PRO 6000 in the EU.
The Server Edition as a card or in a server we build
We supply the NVIDIA RTX PRO 6000 Blackwell Server Edition across the EU, as a card for servers you already run or in AI servers built to order, on one EU contract and invoice with manufacturer warranty. For a server you already run, the maker’s list decides, as set out above. Our reference configurations pair two AMD EPYC processors with two cards and 384 GB of DDR5 ECC memory or with four cards and 768 GB, and we check the rack, power and airflow before we quote. The professional NVIDIA GPUs we supply include the other RTX PRO, L40S, L4 and H200 NVL cards, and NVIDIA AI Enterprise and vGPU licences come on the same invoice.
FAQ
Which servers support the RTX PRO 6000 Blackwell Server Edition?
Can I put an RTX PRO 6000 Server Edition in a Dell PowerEdge R760xa?
Can I add an RTX PRO 6000 Server Edition to my existing server?
Which HPE ProLiant servers support the RTX PRO 6000 Server Edition?
Are NVIDIA RTX PRO Servers NVIDIA-Certified Systems?
Why does my RTX PRO 6000 Server Edition run at 450 W?
Send us the server model and configuration you run, or the models and users a new server should serve. We answer with the cards or a server configuration in a written quote. We reply within one business day.
Request a configurationWe reply within one business day