- Supermicro sells SFT-DCMS-SINGLE as "a per-node Supermicro Data Center Management Suite (DCMS) license" that includes all features of SFT-OOB-LIC and opens its management tools, from SuperCloud Composer to the SuperServer Automation Assistant
- Supermicro's Update Manager page states that "SFT-DCMS-SINGLE or SFT-OOB-LIC is required for each target node"; SUM covers X10 to X13 and H13 boards, and X14 and H14 boards, those of Supermicro's HGX B200 and B300 servers among them, move to the SuperServer Automation Assistant
- Staged firmware updates through Supermicro's Redfish interface require an SFT-DCMS-Single licence and are supported on X13/H13 and X14/H14; whether a plain BIOS update over the BMC needs one on X14 is not stated on the pages we read
- ASUS licenses ASUS Control Center Data Center Edition per device; its HGX servers use an AST2600 with the ASMB11-iKVM controller
- Gigabyte includes the HTML5 iKVM of its Management Console "with no additional add-on license required", and offers GIGABYTE Server Management as a free download
Supplied by Eurokommerz: AI servers, built to order Request a configuration →
Management licences in a GPU server quote
A GPU server's BMC works without an extra licence for the basics, but each of the three makers puts some management functions behind a licence or a separate tool. At Supermicro the licence is a quote line per server: SFT-DCMS-SINGLE, a per-node key that includes all features of the smaller SFT-OOB-LIC and is required for staged firmware updates over Redfish and for each node that the Supermicro Update Manager touches. ASUS licenses its fleet tool, ASUS Control Center Data Center Edition, per device. Gigabyte provides the HTML5 remote console of its BMC without an add-on licence and offers its multi-server tool as a free download.
This guide reads the licence names and what each covers as the makers print them, read on 27 November 2026. What the BMC reads from the GPUs is a subject of its own, in our article on GPU out-of-band monitoring with BMC and Redfish, and the order in which BMC, BIOS and GPU firmware are updated is in GPU server firmware updates.
We supply servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project. For the three makers covered here, the management licences come as lines of the same quote. Tell us how many servers you run and the tools your team uses for updates, and we reply with the licence lines each maker requires for that setup.
Supermicro SFT-DCMS-SINGLE and SFT-OOB-LIC
Supermicro's European eStore describes the two keys on the product page of SFT-DCMS-SINGLE.
| ITEM | AS PRINTED |
|---|---|
| Licence type | "a per-node Supermicro Data Center Management Suite (DCMS) license" |
| Scope | "complete access to all advanced Supermicro BMC functionalities and the entire Data Center Management Software suite" |
| Tools named | SuperCloud Composer, Supermicro Server Manager (SSM), SuperServer Automation Assistant, plug-ins, Super Diagnostics Offline, IPMIView, Thin-Agent Service |
| Relation to SFT-OOB-LIC | "SFT-DCMS-SINGLE included all features from SFT-OOB-LIC" |
| Prerequisite for | SFT-SDDC-SINGLE and SFT-DCMS-SVC-KEY |
| Compatible boards | X11 to X14, H12 to H14 |
Supermicro eStore Europe, product page "Datacenter Management Suite SFT-DCMS-LIC-SINGLE", read 27 November 2026.
Two consequences follow for a quote. SFT-DCMS-SINGLE is the larger key: where it is on the quote, SFT-OOB-LIC adds nothing. And both are counted per node, so four servers need four keys by the wording of the page. The eStore page does not list the functions of SFT-OOB-LIC on its own, and we did not read Supermicro's licence brief for SuperCloud Composer, so the tiers of that product are not covered here.
The management software that Supermicro lists for its HGX B300 server SYS-822GS-NB3RT, SuperCloud Composer, Supermicro Server Manager, Super Diagnostics Offline, the Thin-Agent Service and the SuperServer Automation Assistant, is the same set the DCMS key opens, as our review of the SYS-822GS-NB3RT lists it.
Supermicro Update Manager, SAA and Redfish updates
The licence question usually comes up with firmware, because updates across several servers are scripted. Supermicro's page for the Supermicro Update Manager (SUM) states: "SFT-DCMS-SINGLE or SFT-OOB-LIC is required for each target node". The same page gives SUM's range as X10 to X13 and H13 boards, and names the SuperServer Automation Assistant (SAA) for "X14/H14 and later".
The function table on the SUM page marks some rows with a licence footnote: GPU information and firmware update, firmware update of add-on NICs, RAID functions, Root of Trust and lockdown mode. The rows for BIOS and BMC firmware updates carry no footnote. The page does not call them free either, so we read the general per-node sentence as applying to them.
Supermicro's Redfish user guide 5.2, in its section on the firmware inventory and update service, says that a staged firmware update "requires an SFT-DCMS-Single license" and that staged updates are "supported only for X13/H13 and X14/H14". The components it lists for such updates are the BMC, the BIOS, the CPLD and the backplane CPLD, Broadcom and Marvell storage controllers, add-on NICs, the UBB CPLD and the UBB retimers. We read UBB as the GPU baseboard of HGX systems. A GPU itself is not in that list.
| TASK | SUPERMICRO STATES | KEY |
|---|---|---|
| Any SUM operation on a node | licence "required for each target node" | SFT-DCMS-SINGLE or SFT-OOB-LIC |
| GPU data and firmware in SUM | footnoted as licensed | as above |
| BIOS, BMC update in SUM | no footnote; per-node sentence applies | as above, by our reading |
| Staged Redfish update | "requires an SFT-DCMS-Single license", X13/H13 and X14/H14 only | SFT-DCMS-SINGLE |
| Plain BIOS update via BMC, X14 | not stated on the pages read | ask Supermicro |
Supermicro "Supermicro Update Manager" page and Redfish user guide 5.2, section "Firmware inventory and update service", read 27 November 2026.
Supermicro's HGX boards are X14 and H14
Supermicro builds its 8U HGX servers on fourteenth-generation boards. The Intel models SYS-822GS-NBRT (HGX B200) and SYS-822GS-NB3RT (HGX B300) sit on X14DBG-LC boards (Supermicro prints X14DBG-LC+ for the first and X14DBG-LC for the second), the AMD model AS-8126GS-NB3RT (HGX B300) on an H14DSG-OM. By the SUM page, fleet updates on these servers go through the SAA, which is one of the tools the DCMS key opens; by the Redfish guide, a staged update of the BIOS or of the baseboard CPLD and retimers needs that key as well. For an HGX server whose firmware your team updates by script, we therefore put SFT-DCMS-SINGLE on the quote for every node, by our judgement. The update sequence that NVIDIA documents for its DGX B300, with the GPU tray after the BMC and the motherboard components, is in our firmware update guide.
ASUS ASMB11-iKVM and ASUS Control Center
ASUS's datasheets name the ASMB11-iKVM on an ASPEED AST2600 as the BMC of the ESC NB8-E11 (HGX B200) and of the XA NB3I-E12 (HGX B300); the ESC NB8-E11 datasheet adds ASUS Control Center and a hardware root of trust. One datasheet of the XA NB3I-E12, version V1, also writes "On-Board ASMB12-iKVM" in another section, while the datasheet with the file date 19 September 2025 names only the ASMB11. ASUS publishes no comparison of the ASMB11 and ASMB12 on the pages we read, so confirm the controller of the configured system in the quote.
The licence sits in the fleet tool. ASUS's page for ASUS Control Center Data Center Edition says that its licence model "calculates total cost simply by multiplying the number of devices", a count per device. The page lists support for "industry standards like Redfish and IPMI", "One-click, scheduled, or automated updates across the fleet", and an agentless mode for "essential hardware monitoring, power control, and firmware updates". A free tier or a trial is not mentioned there. ASUS also names an ACC Express edition, which we did not read. The servers themselves are described in our reviews of the ASUS ESC NB8-E11 and the ASUS XA NB3I-E12.
Gigabyte Management Console, GSM and GPM
Gigabyte's HGX servers carry an AST2600, named on the model pages, and the BMC web interface is the GIGABYTE Management Console (GMC). Gigabyte's glossary page on the BMC describes GMC as an IPMI web interface with "RESTful API support", and says of its HTML5 remote console that it is "included as a standard feature with no additional add-on license required to purchase". The same glossary still names the older AST2300, AST2400 and AST2500 controllers in its general text; the HGX model pages name the AST2600.
For several servers, GIGABYTE Server Management (GSM) is "available as a free download" and "an add-on software package", with multi-server monitoring, power cycling and BIOS updates in its description. Gigabyte's GIGAPOD pages list the GIGABYTE POD Manager (GPM) as "Optional"; its licence terms were not on the pages we read. The Gigabyte HGX models are covered in our article on Gigabyte G894 servers for HGX B200 and B300.
BMC updates are security updates
The update licence matters because BMC firmware is patched like any other exposed software. Our firmware guide cites CVE-2024-54085, an authentication bypass in AMI's MegaRAC SPx BMC firmware, scored 10.0 by AMI and listed in CISA's Known Exploited Vulnerabilities Catalog since 25 June 2025. The maker pages we read do not say which BMC firmware stack each of the three uses, so the CVE is an example of the class, not a statement about these servers. For the quote it means that the tool and the licence that apply BMC and BIOS releases belong in the plan from the first day, not after the first advisory.
Each BMC also needs its own port. NVIDIA's Enterprise Reference Architecture counts 12 management connections of 1 Gb/s per HGX B200 server and 6 per HGX B300 server on the out-of-band network, and that network is where the maker's fleet tool reaches the controllers. To check what a BMC reports before and after an update, read the Redfish firmware inventory under /redfish/v1/; Supermicro's X14/H14 BMC manual also documents a GPU tab with model, serial number and firmware version, as our article on out-of-band monitoring notes.
What stays the same across the three makers
The licences change how the BMC and the maker's tools are used, not how the GPUs are monitored from the operating system. Redfish is the common interface on all three: Supermicro documents its Redfish guide, ASUS names Redfish and IPMI for its Control Center, and Gigabyte names a RESTful API for GMC. On the host, NVIDIA's DCGM and nvidia-smi read the GPUs through the driver on every maker's server, and Xid errors appear in the kernel log whatever BMC sits on the board. Our article on GPU server automation with Ansible shows how driver and host settings are rolled out the same way across mixed hardware.
Which licence to put in the quote for one to four GPU servers
| MAKER | QUOTE LINE | COUNTED | WHEN (OUR VIEW) |
|---|---|---|---|
| Supermicro, X14/H14 boards | SFT-DCMS-SINGLE | per node | updates by SAA or staged Redfish, or any DCMS tool |
| Supermicro, X13/H13 and older | SFT-OOB-LIC or SFT-DCMS-SINGLE | per node | SUM updates; DCMS for the full tool set |
| ASUS | ASUS Control Center Data Center Edition | per device | a fleet tool for scheduled updates and monitoring |
| Gigabyte | none for the HTML5 iKVM; GSM as free download | no licence line | GPM is listed as an option on GIGAPOD pages |
makers' pages as cited above, read 27 November 2026; the "when" column is our recommendation.
For one to four Supermicro HGX servers that comes to one to four DCMS keys. For ASUS the question is whether the team wants the fleet tool at all; with one or two servers the BMC's web interface and Redfish may be enough, and with four, by our judgement, the scheduled updates of the Control Center save repeated manual work. For Gigabyte no management licence line is needed for the remote console. How these lines sit next to the rest of a quote is in our guide to comparing GPU server quotes line by line.
For HGX B200 and B300 servers the quote also follows the project review: we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it, as our guide to the end-user certificate for NVIDIA GPUs explains. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO. Send us the server models and your update tooling, and the written quote lists the licence lines next to the hardware.
FAQ
What is Supermicro SFT-DCMS-SINGLE?
Do I need SFT-OOB-LIC if I buy SFT-DCMS-SINGLE?
Does a Supermicro BIOS update need a licence?
Is ASUS Control Center free?
Does Gigabyte charge for the BMC remote console?
Which BMC do HGX servers from ASUS and Gigabyte use?