ultraFluidX, nanoFluidX and EDEM GPU requirements and the server for Altair CFD
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- ultraFluidX needs at least one NVIDIA GPU with compute capability 3.5 and driver 450.80.02 or higher, always runs under MPI, and Altair "strongly recommended to use a minimum of four GPUs based on the NVIDIA Ampere Architecture"
- nanoFluidX 2026 needs a CUDA-enabled GPU and driver 525.60.13 (Linux) or 528.33 (Windows), and asks for system RAM per node of at least the combined GPU memory, twice that recommended
- EDEM 2026 needs compute capability 3.5 and CUDA 11.0 or later, recommends V100, A100 and H100 class cards, and requires the CUDA GPU solver for polyhedral and sphero-cylinder particles
- Altair's tests of June 2025, published on Siemens's blog, took an ultraFluidX case from 2,744 s on one H200 to 470 s on eight; Altair's pages name no Blackwell GPU
- We supply HGX H200 servers per project from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo and build H200 NVL servers to order; the Altair licences come from Altair, now part of Siemens
Supplied by Eurokommerz: HGX H200 servers Request a price →
Which GPU ultraFluidX, nanoFluidX and EDEM need
Altair's three GPU-native solvers set low minimums and high recommendations. ultraFluidX, the Lattice Boltzmann solver for external aerodynamics and virtual wind tunnels, runs on any NVIDIA GPU with compute capability 3.5 and driver 450.80.02 or later, but Altair strongly recommends at least four Ampere-generation GPUs; nanoFluidX (SPH, for gearbox oiling and e-motor cooling) and EDEM (DEM, for bulk materials) ask for current NVIDIA data-centre or RTX cards. The multi-GPU timings Altair has published were run on eight H200 GPUs, which is the GPU count and model of an HGX H200 server.
This guide is for automotive, drivetrain and process engineers who run these solvers and want to move them from shared workstations to a GPU server. Altair is now part of Siemens, and Altair's pages still carry the requirements; every figure below is quoted from them with the page named. General GPU questions for CFD with Fluent and STAR-CCM+ are in our guide to GPUs for CFD simulation, and DEM and SPH with Ansys Rocky in our Rocky sizing guide.
We supply HGX H200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project, and build servers with H200 NVL or RTX PRO 6000 Server Edition cards to order. Send us the solver, its release and the largest case you run, and we reply with a configuration within one business day.
| SOLVER | METHOD | GPU REQUIREMENT | MULTI-GPU | PUBLISHED SCALING |
|---|---|---|---|---|
| ultraFluidX | Lattice Boltzmann | CC 3.5+, driver 450.80.02+ | min. four Ampere GPUs advised | 2,744 s on 1 H200, 470 s on 8 |
| nanoFluidX 2026 | SPH | CUDA GPU, 525.60.13 / 528.33 | multi-node, e.g. InfiniBand | 8 H200: 5.74x one H100 |
| EDEM 2026 | DEM | CC 3.5+, CUDA 11.0+ | not on 2026 page | 8 H200: 5.31x one H100 |
Altair help pages "Use ultraFluidX" (Virtual Wind Tunnel help, no version shown), nanoFluidX 2026 platform and hardware requirements, EDEM 2026 hardware requirements, and the Siemens HPC blog of 27 August 2025 ("Originally Published by Altair", last modified 2 June 2026), all read 28 November 2026.
ultraFluidX GPU requirements and multi-GPU runs
The ultraFluidX requirements page, re-opened on 28 November 2026, states that the solver "requires at least one NVIDIA GPU device with compute capability 3.5 or higher" and "NVIDIA drivers version 450.80.02 or higher". It then adds the sentence that matters for buying: "it is strongly recommended to use a minimum of four GPUs based on the NVIDIA Ampere Architecture". Altair's HyperWorks 2025 CFD platform page gives the NVIDIA A100 as the example.
MPI is not optional. "ultraFluidX always needs MPI to run a simulation." Rank 0 handles preprocessing and I/O, and each further rank drives one GPU, so the solver "must be started with a minimum of 2 MPI ranks to use at least 1 GPU device". A run on eight GPUs therefore starts nine ranks, by our count from that rule. CUDA_
The operating-system line is older than the rest. The HyperWorks 2025 page keeps the sentence that ultraFluidX "requires a 64-bit Linux operating system and is certified for RHEL/CentOS 6.8 (64-bit)", while its platform table lists Windows 10 and 11 and RHEL / CIQ Rocky Linux 9.4. An even older Altair page, still online with CentOS 6.8 and CUDA 8.0, recommended "NVIDIA P100 GPUs (or better)" and "a minimum of 256 GB main memory" for large production models; we cite it only as Altair's earlier guidance. Plan a new server on Rocky Linux or RHEL 9.4 and confirm the release with Altair.
What Altair does not publish matters as much. The ultraFluidX 2026 release notes contain no item on GPUs, CUDA, Hopper or Blackwell. We found no figure for GPU memory per million voxels and no statement of the floating-point precision the solver computes in, and the requirements page names no GPU interconnect.
nanoFluidX for gearbox oiling and e-motor cooling
nanoFluidX is Altair's GPU-native SPH solver, used for gearbox oiling, e-motor cooling and sloshing. Its 2026 requirements page, re-opened on 28 November 2026, opens with "The hardware system that is intended to run nanoFluidX must contain a CUDA-enabled GPU" and recommends "NVIDIA Enterprise GPUs, data center, and RTX series" for HPC use. From version 2024.1, Kepler Tesla cards (K20, K40, K80) are no longer supported. The driver must be 525.60.13 (Linux) or 528.33 (Windows) or later.
The page is the only one of the three that sizes the rest of the machine:
- System RAM: "Minimum RAM per node is at least equal to the RAM of GPUs combined per node", and "Twice the combined GPU RAM size is recommended."
- CPU: at least one core per GPU, "Ideally" slightly more cores than GPUs.
- Network: "High speed interconnect for multi-node systems, for example Infiniband."
- Storage: "3TB HDD space (long-term storage) or 500GB for operational drive", with output that "can vary from 20 to 400 GB, depending on the size of the case".
Altair 2026.0 officially supports Windows 11 and RHEL / CIQ Rocky Linux 9.4; other Linux distributions may work but are not tested, and the page states that Windows 10 is no longer supported in Altair 2026.0. The 2026 release notes add one hardware line: "nanoFluidX now supports ARM platforms, making it ready to run on NVIDIA's Grace Superchip products." The page also notes that "Each GPU generation and model has specific single precision and double precision performance", without saying which precision nanoFluidX uses. On Windows workstations, Altair's older nanoFluidX help found no clear gain from TCC mode, as our article on WDDM, TCC and MCDM driver modes quotes.
EDEM GPU solver for bulk materials
EDEM 2026 asks for a "CUDA enabled GPU with compute capability at least 3.5" and "minimum version 11.0 of the CUDA Toolkit". Altair recommends Volta (V100), Ampere (A100) and Hopper (H100) cards, and states that "Only NVIDIA GPU cards support the EDEM CUDA GPU Solver." For some models the GPU is not a choice: "CUDA GPU is required for simulations using Sphero-Cylinder and Polyhedral particles." The 2026 page gives no GPU memory guidance, no precision and no multi-GPU statement, so the card count for EDEM follows from the published benchmark below and from a pilot.
Published scaling on H200: what the three tests show
The Siemens HPC blog post of 27 August 2025, originally published by Altair, reports tests that Altair ran with a cloud provider: the ultraFluidX run is dated June 2025, and the nanoFluidX and EDEM runs used a cloud virtual machine with eight H200 GPUs. They are the only multi-GPU figures for these solvers we found.
| TEST | BASELINE | RESULT | FACTOR | OUR NOTE |
|---|---|---|---|---|
| ultraFluidX, ARC model | 1 × H200: 2,744 s | 8 × H200: 470 s | 5.84, our division | 73 % per GPU, our arithmetic |
| nanoFluidX, ten tests | 1 × H100 | 8 × H200 | 5.74x average | baseline is a different GPU |
| EDEM, Powder Mixer | 1 × H100 | 8 × H200 | 5.31x throughput | baseline is a different GPU |
Siemens HPC blog post of 27 August 2025, originally published by Altair, read 28 November 2026. Factor and per-GPU share for ultraFluidX are our arithmetic (2,744 ÷ 470 = 5.84; 5.84 ÷ 8 = 73 %).
The ultraFluidX figure is a clean scaling result on one GPU model: "Total compute time decreased from 2,744 seconds (45m 44s) on a single H200 GPU to 470 seconds (7m 50s) on eight H200 GPUs". By our arithmetic each GPU delivers about 73 % of its single-GPU rate in the eight-GPU run. The nanoFluidX and EDEM results compare eight H200 with one H100, so they mix the generation change with the GPU count and cannot be read as scaling alone. None of the three tests covers a Blackwell GPU.
The server for Altair's GPU solvers
Altair names no RTX PRO Blackwell or B200 card on any page we read. The card choice below is our reasoning from Altair's own recommendations and the published tests, and we suggest confirming it with a pilot on your own case.
| SERVER | GPU MEMORY | GPU LINK | SYSTEM RAM, NFX RULE | ROLE |
|---|---|---|---|---|
| HGX H200, 8 × H200 SXM | 1.1 TB (8 × 141 GB) | NVLink, 900 GB/s per GPU | 1,128 GB min., 2,256 GB advised | mirrors the tests |
| 4 × H200 NVL | 564 GB | 4-way bridge, 900 GB/s | 564 GB min., 1,128 GB advised | four GPUs, smaller step |
| 4 × RTX PRO 6000 SE | 384 GB | no NVLink | 384 GB min., 768 GB advised | only after a pilot |
HGX H200 and H200 NVL figures as in our guides to buying an HGX H200 server and to four H200 NVL servers (NVIDIA's H200 product page and HGX reference architecture); RTX PRO 6000 Server Edition from NVIDIA's product brief; system RAM is our arithmetic from the nanoFluidX rule (GPU memory × 1 and × 2).
HGX H200. Eight H200 SXM GPUs with 141 GB each, 1.1 TB per system as NVIDIA prints it, joined through NVSwitch at 900 GB/s per GPU. It is the configuration of all three published tests and twice the four GPUs Altair recommends for ultraFluidX. Supermicro, ASUS and Gigabyte build it, for example as the Supermicro SYS-821GE-TNHR with 32 DIMM slots and up to 4 TB at 5600 MT/s, so the 2,256 GB that the nanoFluidX rule recommends fits. NVIDIA rates each H200 SXM at up to 700 W, 5.6 kW for the GPUs alone, and our HGX H200 buying guide covers models, power and the quote. Whether a newer board is the better buy is the subject of our comparison of HGX H200 and HGX B200.
Four H200 NVL. The smaller step meets Altair's four-GPU recommendation with the same Hopper chip, 141 GB per card, and a 4-way NVLink bridge. The cards draw 2.4 kW at 600 W, and the 1,152 GB of system memory we quote for such a server by NVIDIA's 2× rule also covers the nanoFluidX recommendation of 1,128 GB. Our guide to the four H200 NVL server sets out bridges, processors and power, and the card itself is on our H200 NVL page.
RTX PRO 6000 Server Edition. nanoFluidX recommends RTX series cards among others, and 96 GB per card is a lot of memory for SPH. Two things are open: Altair has not published results on Blackwell, and none of the three solvers states its precision, while the RTX PRO 6000 computes FP64 at 1/64 of its FP32 rate. Our guide to FP64 GPU servers sets out what that means. Run one of your cases on the card before ordering a server of them.
For storage, plan the 500 GB operational drive and 3 TB of long-term space that nanoFluidX names as a floor, and size up from the 20 to 400 GB each case writes. A team that keeps every variant of a gearbox study needs more, and by our reading a fast NVMe volume for running cases and a larger store for archived results keep the two needs apart.
Ordering the server, and what Altair supplies
For an HGX H200 order we need the end user's company, the installation site and the intended use. The server maker and NVIDIA review the project before they confirm it, and our guide to the end-user certificate for NVIDIA GPUs shows what the declaration contains. Your data-centre staff or colocation provider rack and connect the server. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO; warranty and service come from the server maker, handled through us.
ultraFluidX, nanoFluidX and EDEM licences are bought from Altair, now part of Siemens, and we do not sell them. The pages we read give no licence count per GPU, so ask Altair how your licence model counts GPUs before you fix the card count. What we write about licences here is general information. To plan budgets, companies can request our current NVIDIA price list. Teams that combine CFD with AI surrogate models will find that workload mix in our guide to an AI server for automotive R&D.
Describe your solver mix, case sizes and the run times you see today, and we propose a server with the GPU count, system memory and storage sized to it.
FAQ
What are the ultraFluidX GPU requirements?
Does ultraFluidX run on multiple GPUs?
Which GPU does nanoFluidX need?
How much RAM does a nanoFluidX server need?
Does Altair EDEM need a GPU?
Is the RTX PRO 6000 supported by ultraFluidX or nanoFluidX?
We supply HGX H200 servers per project and H200 NVL or RTX PRO 6000 Server Edition servers to order for Altair's GPU solvers. Send us your solvers, case sizes and run times. We reply within one business day.
Request a priceWe reply within one business day