- An HGX H200 server has eight H200 SXM with 141 GB each, 1.1 TB, 4.8 TB/s per GPU and NVLink at 900 GB/s per GPU; an HGX B200 server has eight B200 with 180 GB each, 1.4 TB, up to 8 TB/s and 1.8 TB/s
- NVIDIA's HGX page gives the HGX B200 36 PFLOPS of dense FP8 and 72 PFLOPS of dense FP4; eight H200 SXM come to about 15.8 PFLOPS of dense FP8 by our arithmetic and have no FP4 arithmetic
- On FP64 Tensor Cores eight H200 SXM list 536 TFLOPS by our multiplication against 296 TFLOPS printed for the whole HGX B200
- Each H200 SXM is rated up to 700 W and each B200 up to 1,000 W; NVIDIA gives its own DGX H200 10.2 kW and its DGX B200 14.3 kW maximum
- The B200 needs CUDA 12.8 or later and an R570 driver or newer; Hopper keeps compute capability 9.0, so software built for the H100 runs on the H200 unchanged
Supplied by Eurokommerz: HGX B200 servers Request a price →
H200 vs B200 at a glance
An HGX B200 server holds 1.4 TB of HBM3e on eight B200 GPUs, joins them with NVLink at 1.8 TB/s per GPU and computes in FP4; an HGX H200 server holds 1.1 TB on eight H200 SXM at 900 GB/s per GPU, with FP8 as its smallest floating-point Tensor Core format. The B200 board suits large models, FP4 serving and speed per user, while the H200 board keeps the Hopper software stack, more FP64 on Tensor Cores and a lower power class.
Both are server makers' systems built around an NVIDIA HGX board, and we supply both per project from Supermicro, ASUS, Gigabyte, HPE and Lenovo, with warranty and service from the server maker handled through us. Our page on HGX B200 servers describes the newer one, and our guide to buying an HGX H200 server lists the H200 models with their power supplies and weights. We size the choice per model and rack; send us your models, their precision and the feed at the rack position and we answer with the generation that fits and a configuration for it.
| ASPECT | HGX H200 | HGX B200 |
|---|---|---|
| GPUs | 8 × H200 SXM, Hopper | 8 × B200 SXM, Blackwell |
| GPU memory | 141 GB each, 1.1 TB | 180 GB each, 1.4 TB |
| Usable by our rule | about 986.9 GiB | about 1,183 GiB |
| Memory bandwidth per GPU | 4.8 TB/s | up to 8 TB/s |
| NVLink per GPU | 900 GB/s | 1.8 TB/s |
| FP8 Tensor, dense | about 15.8 PFLOPS | 36 PFLOPS |
| FP4 Tensor, dense | no FP4 arithmetic | 72 PFLOPS |
| FP64 / FP64 Tensor | 272 / 536 TFLOPS | 296 TFLOPS |
| Power per GPU | up to 700 W | up to 1,000 W |
| NVIDIA's own system | DGX H200, 10.2 kW max. | DGX B200, 14.3 kW max. |
| Compute capability | 9.0 | 10.0, CUDA 12.8 or later |
NVIDIA's HGX platform page (HGX B200 column; FP8 printed sparse with "Dense is ½ sparse spec shown", FP4 sparse and dense, one FP64 / FP64 Tensor row), H200 product page, HGX AI Factory reference architecture (components page dated 18 May 2026), HGX B200 carbon footprint summary (up to 1,000 W), DGX B200 and DGX H100/H200 user guides (updated 17 October 2026) and CUDA GPU list, all read 27 November 2026. HGX H200 FP8 and FP64 are our arithmetic from NVIDIA's per-GPU figures; usable memory is our estimate.
Memory: 1.1 TB against 1.4 TB
NVIDIA's reference architecture prints 1.1 TB for an HGX H200 node with 141 GB per GPU, and NVIDIA's DGX H100/H200 user guide gives 1,128 GB, eight times 141 GB, for the DGX H200. For the HGX B200 the HGX page prints 1.4 TB, eight times 180 GB. Our users-per-card rule takes 90 per cent of the memory per GPU and keeps 3 GiB for CUDA graphs and activations. On the H200 it gives 123.4 GiB per GPU from the 140.4 GiB the driver reports on the H200 NVL, the same chip, and about 986.9 GiB for eight, the figure our comparison of H200 NVL and H200 SXM uses for both. NVIDIA publishes no driver figure for the B200, so we read 180 GB as 10⁹ bytes and get 147.9 GiB per GPU and about 1,183 GiB per server; the driver on the delivered system decides both figures.
| MODEL | WEIGHTS | LEFT, HGX H200 | LEFT, HGX B200 |
|---|---|---|---|
| Llama 3.3 70B, FP8 | 67.7 GiB | 919.2 GiB | 1,115.3 GiB |
| Qwen3-235B-A22B-2507, FP8 | 219.8 GiB | 767.1 GiB | 963.2 GiB |
| DeepSeek-V4-Pro-0813 | 831.4 GiB | 155.5 GiB | 351.6 GiB |
| Kimi-K2-Instruct-0905, FP8 | 958.5 GiB | 28.4 GiB | 224.5 GiB |
| Kimi-K3.1-Pro, MXFP4 | 1,454.1 GiB | does not fit | does not fit |
weights as Hugging Face repository sizes in our model guides (September to November 2026), as listed in our guide to LLMs on an HGX B200 server; memory left on the whole server by our users-per-card rule.
Up to about 230 GiB of weights the two boards differ mainly in how many conversations they hold. For Llama 3.3 70B in FP8 as one copy over all eight GPUs, with an FP8 KV cache of 1.25 GiB per conversation of 8,192 tokens, the HGX H200 holds 735 and the HGX B200 892 by our estimate. The gap widens with the size of the model. DeepSeek-V4-Pro stores its latent cache in full on every GPU under tensor parallelism, so the spare memory of one GPU sets the count: about 19.4 GiB per H200 and 43.9 GiB per B200, or 64 against 146 conversations of 32K with a 16-bit cache at 0.30 GiB each. The FP4 expert weights of that model stay in 4-bit on Hopper and are computed at higher precision; the B200 computes them in FP4. Kimi-K2-Instruct in FP8 leaves about 3.5 GiB per H200, room for about one conversation of 32K, as our comparison of the HGX B200 with eight H200 NVL notes for the same memory. Our guide to how many users an HGX B200 server serves works through the conversation counts by model and GPU count.
FP8, FP4 and BF16: dense and sparse figures
NVIDIA prints the Tensor Core rows of both GPUs with structured sparsity. The H200 page gives 3,958 TFLOPS of FP8 and 1,979 TFLOPS of FP16/BF16 per H200 SXM, both with sparsity; eight GPUs make 31.7 and 15.8 PFLOPS sparse, and 15.8 and 7.9 PFLOPS dense, by our arithmetic. The HGX page gives the HGX B200 72 PFLOPS of FP8 and 36 PFLOPS of FP16/BF16 with sparsity, with the footnote "Dense is ½ sparse spec shown", so 36 and 18 PFLOPS dense. On dense FP8 that is about 2.3 times the H200 board by our arithmetic.
FP4 is the larger step. The HGX page prints 144 PFLOPS sparse and 72 PFLOPS dense for the HGX B200. Hopper has no FP4 arithmetic, so an NVFP4 checkpoint runs on the H200 only as a weight-only format, stored in 4 bits and computed at 16-bit, as our guide to FP4 models on H200 NVL and Ada GPUs explains for the same chip. Compare dense with dense: NVFP4 checkpoints do not use the structured sparsity behind the larger figures. The formats themselves are explained in FP8, NVFP4, MXFP4 and INT4.
NVLink and memory bandwidth: 900 GB/s against 1.8 TB/s
Both boards connect all eight GPUs through NVSwitch, so tensor parallelism over eight GPUs stays on NVLink on either. The H200 SXM has 900 GB/s of NVLink per GPU, 7.2 TB/s across eight by our multiplication, which is also the figure our H200 NVL vs H200 SXM comparison quotes from NVIDIA's reference architecture. The HGX B200 has fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total on NVIDIA's HGX page. Twice the link rate matters for the all-reduce after every layer of a split model and for the gradient exchange in training across all eight GPUs; the documents we read give no measurement that turns this into a speed ratio for a given model, and we give none.
Memory bandwidth sets the ceiling for one user's token rate: bandwidth divided by the bytes read per token. Llama 3.3 70B in FP8 reads about 70.6 GB per token, which gives at most about 68 tokens per second on one H200 at 4.8 TB/s and about 113 on one B200 at 8 TB/s, by our estimate. In NVFP4, about 40.6 GB per token, the B200 ceiling is about 197. These are upper bounds from published figures, never reached in practice.
FP64: where the H200 board stays ahead
FP64 on Tensor Cores is the one compute figure where Hopper leads. NVIDIA lists 34 TFLOPS of FP64 and 67 TFLOPS of FP64 Tensor Core throughput per H200 SXM, 272 and 536 TFLOPS for eight by our multiplication. NVIDIA's HGX page prints one figure for the HGX B200 in its FP64 and FP64 Tensor Core row: 296 TFLOPS, about 37 per GPU by our division. Codes that run their matrix work through FP64 Tensor Cores have about 1.8 times the peak on the H200 board; codes on plain FP64 vector units are about 9 per cent faster on the B200 board on paper. The HGX B300 is not a step up here: NVIDIA lists 10 TFLOPS for its eight GPUs, as our FP64 GPU server comparison shows.
Power class, chassis and the rack
NVIDIA rates the H200 SXM up to 700 W, configurable, and the B200 configurable up to 1,000 W in its HGX B200 carbon footprint summary. Eight GPUs alone come to 5.6 kW and 8 kW. No server maker publishes a system power figure on the pages we read, so NVIDIA's own systems on the same boards are the reference: its DGX H100/H200 user guide gives 10.2 kW maximum, and its DGX B200 user guide 14.3 kW. Two DGX B200 at that rating come to 28.6 kW, which already exceeds a rack planned for 20 kW. The makers' chassis show the same step.
| MAKER | HGX H200 MODEL | HGX B200 MODEL |
|---|---|---|
| Supermicro, 8U, air | SYS-821GE-TNHR: 6 × 3,000 W in 4+2, 843.28 mm, 75.3 kg net | SYS-822GS-NBRT: 6 × 6,600 W in 3+3, 950 mm, 133 kg net |
| Gigabyte, 8U, air | G893-SD1-AAX3: 8 × 3,000 W in 4+4 | G893-SD1-AAX5: 12 × 3,000 W in 6+6 |
| ASUS, air | ESC N8-E11: 7U, 6 × 3,000 W in 4+2, 113 kg net | ESC NB8-E11: 10U, 6 × 3,000 W in 5+1, 121 kg net |
Supermicro product pages for the SYS-821GE-TNHR and SYS-822GS-NBRT; Gigabyte product pages G893-SD1-AAX3 and G893-SD1-AAX5; ASUS datasheets ESC N8-E11 (29 August 2024) and ESC NB8-E11 (29 May 2025), whose weights exclude processors, memory and drives; all read 27 November 2026.
Gigabyte's 8U pair shows the difference most plainly: the B200 version of the G893 has twelve 3,000 W supplies where the H200 version has eight. Supermicro's B200 server needs supplies of more than twice the rating and weighs 57.7 kg more net by our subtraction. A rack position planned for the 10.2 kW of a DGX H100 or H200 is planned for the H200 power class; for an HGX B200 server, check the feeds and the rack budget against the B200 class first, as our article on HGX B200 server power and cooling does in detail.
Software: the Hopper stack against CUDA 12.8
NVIDIA's CUDA GPU list gives the H200 compute capability 9.0, the same as the H100, and the B200 10.0. CUDA 12.8 added compiler support for SM_100, and NVIDIA's release notes for driver 570.86.15 list the "NVIDIA HGX B200 8-GPU" among the supported systems; the HGX H200 has been validated since driver 550.90.07 (R550, June 2024, CUDA 12.4). For MIG, NVIDIA's MIG user guide (updated 4 November 2026) names R570 570.133.20 for the B200 and R550 550.90.07 for the H200, with up to seven instances per GPU on both: 1g.23gb on the B200, 1g.18gb on the H200.
The move from 9.0 to 10.0 is a rebuild. Kernels compiled only as machine code for Hopper do not run on Blackwell, so container images, framework builds and custom extensions need code for 10.0, as our article on the "no kernel image" error on Blackwell explains with NVIDIA's compatibility rules. Transformer Engine, according to its README read on 27 November 2026, runs FP8 on Hopper and Blackwell and adds MXFP8 and NVFP4 on Blackwell, with CUDA 12.1 or later for Hopper and 12.8 or later for Blackwell. The NVLink setup changes too: NVIDIA's Fabric Manager user guide requires, for the fourth-generation NVSwitch of the Blackwell boards, an additional NVLSM service, the nvlink5 packages next to the open driver packages on Ubuntu, InfiniBand management libraries and a Linux kernel of 5.17 or later. Our article on HGX B200 server specs and configuration lists the versions for a B200 build.
Which workloads stay on Hopper
- Software validated on the H100 or H200 that you do not want to rebuild and requalify, for instance a pipeline qualified on an H100 system; compute capability 9.0 carries over.
- Simulation and scientific codes that use FP64 Tensor Cores: 536 against 296 TFLOPS by our arithmetic.
- Models such as Llama 3.3 70B or Qwen3-235B in FP8, which leave 767 to 919 GiB for the cache on the H200 board, for a moderate number of users.
- Rack positions planned for the Hopper class, with feeds for a system of about 10 kW like the DGX H200.
Which workloads go to the B200
- Models above about 900 GiB, such as Kimi-K2-Instruct in FP8, or long contexts on latent-cache models, where the 1,183 GiB and the 43.9 GiB per GPU after DeepSeek-V4-Pro decide.
- NVFP4 checkpoints at full speed, and MoE models whose FP4 experts the B200 computes natively.
- Many users per server: 892 against 735 conversations of 8K for Llama 3.3 70B by our estimate, and a decode ceiling of about 113 against 68 tokens per second per stream.
- Training and fine-tuning across all eight GPUs, where 1.8 TB/s of NVLink and 2.3 times the dense FP8 rate on paper count.
If neither board is needed because every model fits four GPUs, a PCIe server with eight H200 NVL is the third option, compared with the B200 board in HGX B200 vs eight H200 NVL. For models above 1.4 TB the next step is the HGX B300, whose trade-offs against the B200 our guide HGX B200 now or HGX B300 later sets out.
Ordering an HGX H200 or HGX B200 server
We supply both generations per project, from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo, on one EU contract and invoice: the same GPUs on the same NVIDIA HGX board as NVIDIA's DGX systems, with warranty and service from the server maker handled through us. We do not supply DGX servers; if you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration.
On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO; racking is done by your data-centre staff or your colocation provider. Companies comparing several purchases can request our current NVIDIA price list. Describe the models, the users at peak and the share of FP64 work, and we reply with both configurations side by side.
FAQ
H200 vs B200: which is faster?
What is the difference between HGX H200 and HGX B200?
Is the H200 or the B200 better for FP64?
How much more power does an HGX B200 server need than an HGX H200 server?
Does software for the H100 and H200 run on the B200?
Should we buy an H200 or a B200 server?