BLOG · HARDWARE REVIEW · · UPDATED

HGX B200 server specs: what sits inside an 8-GPU configuration and why each line matters

Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software

IN BRIEF
  • The HGX B200 board carries eight B200 GPUs with 180 GB of HBM3e each, 1.4 TB per system as NVIDIA prints it, with fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total
  • NVIDIA's HGX page lists 72 PFLOPS of dense FP4 (144 sparse), 36 PFLOPS of dense FP8 (72 sparse) and 296 TFLOPS of FP64 for the eight GPUs; each GPU is configurable up to 1,000 W
  • Processors, system memory, drives, network adapters, power supplies and chassis are the maker's choice: Supermicro's SYS-822GS-NBRT takes two Xeon 6700/6500, 32 DIMMs and eight E1.S drives
  • The B200 board has no network adapters of its own in the documents we read: Supermicro pairs each GPU with a 400 Gb/s ConnectX-7 or BlueField-3 card, while the HGX B300 board carries eight 800 Gb/s ConnectX-8
  • We supply HGX B200 servers per project; for an order we need the end user's company, the installation site and the intended use

Supplied by Eurokommerz: HGX B200 servers  Request a price →

HGX B200 specs: the board as NVIDIA lists it

The HGX B200 is NVIDIA's eight-GPU board: eight Blackwell SXM GPUs with 180 GB of HBM3e each, 1.4 TB per system as NVIDIA's HGX platform page prints it (read 27 November 2026), and fifth-generation NVLink through NVLink 5 switches at 1.8 TB/s per GPU and 14.4 TB/s in total. The same page lists 72 PFLOPS of dense FP4 Tensor Core throughput (144 PFLOPS sparse) and 296 TFLOPS of FP64 for the eight GPUs. Everything around the board, from processors and memory to network cards, power supplies and chassis, is chosen by the server maker, and that is where configurations differ.

We supply HGX B200 servers per project in the configuration your workload needs. For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains why. Send us the models you plan to run and the number of users, and we reply with a configuration line by line.

NVIDIA's HGX page prints most Tensor Core rows with sparsity and notes that dense is half of the figure shown. The table gives both, labelled.

SPECIFICATIONHGX B200, 8 GPUSDOCUMENT
GPUs8 × NVIDIA Blackwell SXMHGX page
GPU memory1.4 TB HBM3e (8 × 180 GB)HGX page
Memory bandwidthup to 8 TB/s per GPUNVIDIA reference architecture
NVLink5th generation, NVLink 5 SwitchHGX page
NVLink bandwidth1.8 TB/s per GPU, 14.4 TB/s totalHGX page
FP4 Tensor Core72 PFLOPS dense, 144 sparseHGX page
FP8/FP6 Tensor Core36 PFLOPS dense, 72 sparseHGX page
INT8 Tensor Core36 POPS dense, 72 sparseHGX page
FP16/BF16 Tensor Core18 PFLOPS dense, 36 sparseHGX page
TF32 Tensor Core9 PFLOPS dense, 18 sparseHGX page
FP32600 TFLOPSHGX page
FP64 and FP64 Tensor Core296 TFLOPSHGX page
Networking bandwidth0.8 TB/sHGX page
GPU powerconfigurable up to 1,000 W per GPUHGX B200 carbon footprint summary

NVIDIA HGX platform page, NVIDIA Enterprise Reference Architecture "HGX AI Factory" components page (page date 18 May 2026) and NVIDIA's HGX B200 carbon footprint summary (July 2025), all read 27 November 2026; dense figures are half the sparse figures per the HGX page's footnote.

NVIDIA's documents do not print the memory in one way. The HGX page says 1.4 TB, the DGX B200 user guide 1,440 GB and the reference architecture 1.44 TB, all for eight times 180 GB. For the aggregate bandwidth, the DGX B200 product page and the reference architecture give 64 TB/s, while the carbon footprint summary says "up to 62 TB/s". We work with about 8 TB/s per GPU. The networking row, 0.8 TB/s against 1.6 TB/s for the HGX B300, comes without an explanation of how NVIDIA counts it. The per-GPU view of the chip is in our NVIDIA B200 specs.

The NVLink switches are the reason to buy the board rather than eight cards. Every GPU reaches every other GPU at the 1.8 TB/s that NVIDIA lists GPU to GPU, so a model split by tensor parallelism across all eight exchanges its activations over NVLink and not over PCIe. A server with eight PCIe cards has no such switch; our comparison of eight RTX PRO 6000 Server Edition or an HGX B200 shows which workloads need it and which do not.

An HGX B200 server configuration line by line

The table sets one maker's server, Supermicro's SYS-822GS-NBRT, against NVIDIA's own DGX B200 on the same board. The first is a typical starting point for a configuration; the second shows the choices NVIDIA made for its system.

COMPONENTSYS-822GS-NBRTDGX B200
GPU boardHGX B200 8-GPU (180GB), 1000W TDP per GPU, air-cooled8 × B200, 1,440 GB
Processors2 × Xeon 6700/6500 with P-cores, up to 86 cores and 350 W2 × Xeon Platinum 8570, 56 cores each
System memory32 DIMMs; 4 TB at 6400 MT/s or 8 TB at 5200 MT/s2 TB in 32 DIMMs, up to 4 TB
Boot drives2 × M.2 PCIe 5.0 x4 NVMe2 × 1.92 TB NVMe M.2, RAID 1
Data drives8 × E1.S NVMe, front hot-swap8 × 3.84 TB NVMe U.2, RAID 0
Expansion slots8 × PCIe 5.0 x16 LP, 2 × x16 FHHLnot listed
Cluster networkadd-in cards in the LP slots4 × OSFP for 8 × ConnectX-7 single-port
Storage networkadd-in cards2 × BlueField-3 dual-port
On-board LAN2 × 10GbE (Intel X710), 1 GbE BMC port10 Gb/s RJ45, dual-port 100 Gb/s, BMC
Power supplies6 × 6,600 W, 3+3, Titanium6 × 3.3 kW, 5+1
Chassis8U, 356 × 449 × 950 mm, 133 kg net10U, 897.1 mm deep, 142.4 kg max
Cooling12 heavy-duty fans, air shroudair, 1,550 CFM

Supermicro product page SYS-822GS-NBRT (©2026) and NVIDIA DGX B200 user guide (updated 17 October 2026), both read 27 November 2026.

Processors and system memory per maker

NVIDIA fixes the GPUs; the processor platform comes from the maker, and it decides the memory channels, the PCIe lanes and the core count. The HGX B200 servers we read span three Intel generations and two AMD ones.

MODELPROCESSORSMEMORY
Supermicro SYS-822GS-NBRT2 × Xeon 6700/6500, up to 350 W32 DIMMs, up to 8 TB
Supermicro AS-A126GS-TNBR2 × EPYC 9005/9004, up to 500 W24 DIMMs, up to 6 TB
Gigabyte G894-SD1-AAX52 × Xeon 6700/6500, up to 350 W32 DIMMs, MRDIMM up to 8000 MT/s
Gigabyte G894-AD1-AAX52 × Xeon 6900, up to 500 W24 DIMMs
ASUS ESC NB8-E112 × 4th/5th Gen Xeon Scalable32 DIMMs, up to 4 TB per CPU

the makers' product pages and datasheets, read 27 November 2026 (ASUS datasheet of 29 May 2025).

For sizing we use the ratios in NVIDIA's configuration guide for NVIDIA-Certified Systems, as cited in our article on CPU, RAM and storage for a GPU server: at least six physical cores per GPU and system memory of twice the GPU memory. For eight B200 that is 48 cores and, by our arithmetic, 2,880 GB of RAM. NVIDIA's own DGX B200 comes with 2 TB and 112 cores, so the memory rule is a starting point and not a limit NVIDIA applies to itself.

On the SYS-822GS-NBRT the memory speed depends on how the slots are filled. Sixteen modules, one per channel, give up to 4 TB at 6400 MT/s; thirty-two modules, two per channel, up to 8 TB at 5200 MT/s on Supermicro's product page. By our arithmetic, 2,880 GB at full speed needs 256 GB modules in sixteen slots, while thirty-two 96 GB modules give 3,072 GB at the lower speed. Supermicro's B300 sibling, the SYS-822GS-NB3RT, now prints 6000 MT/s for two modules per channel, so the speed on the B200 page and the speed in your quote should match.

Drives: boot, model store and scratch

NVIDIA's DGX B200 splits storage in two: a mirrored pair of 1.92 TB M.2 drives for the operating system and eight 3.84 TB U.2 drives in RAID 0 as data cache. The makers offer different drive formats for the same purpose: eight E1.S bays and two M.2 slots on the SYS-822GS-NBRT, ten 2.5-inch bays (eight NVMe, two NVMe or SATA) and two M.2 slots on the ASUS ESC NB8-E11, eight 2.5-inch Gen5 NVMe bays on the Gigabyte G894-SD1-AAX5. The same NVIDIA certified-systems guide asks for at least one NVMe drive of 1 TB or more per CPU socket, and the bays of every model here leave room for far more. The local drives hold the model weights in service and the scratch data of a training run; datasets shared by several servers belong on network storage.

Network: separate 400G cards on the B200, ConnectX-8 on the B300

This is the line where B200 and B300 servers differ most in configuration. NVIDIA's reference architecture describes eight integrated ConnectX-8 SuperNICs at up to 800 Gb/s on the HGX B300 baseboard, one per GPU. For the HGX B200 we found no NVIDIA document that places network adapters on the board. NVIDIA's DGX B200 uses eight ConnectX-7 single-port cards at up to 400 Gb/s, which are PCIe cards, and Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives the SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s)" and two dual-port BlueField-3 DPUs with a "1:1 GPU-to-NIC ratio".

The product page of the same server lists only the slots: eight PCIe 5.0 x16 low-profile slots for the cluster cards and two full-height half-length slots, plus two 10GbE ports and a BMC port on board. Whether the eight cards come with the system is therefore a line of the configuration. ASUS routes eight Gen5 x16 slots through PCIe switches for "one-GPU-to-one-NIC" on the ESC NB8-E11, and Gigabyte lists its G893-SD1-AAX5 and G894-SD1-AAX5 as compatible with ConnectX-7 and BlueField-3.

For one server on its own, NVIDIA's configuration guide says that single-node deployments typically do not require high-speed networking, as our article on the ConnectX-8 SuperNIC in an AI server quotes. Two or more servers that train one model together need the eight cluster cards, the switch ports and the cables. The DPUs serve storage and the north-south network; when a server needs one is covered in BlueField-3 DPU in GPU servers.

Power supplies, chassis and cooling

The power supplies follow the chassis. The SYS-822GS-NBRT has six 6,600 W Titanium supplies as 3+3; the DGX B200 has six 3.3 kW supplies configured for 5+1; ASUS fits six 3,000 W supplies as 5+1 in the ESC NB8-E11; and Gigabyte twelve 3,000 W supplies as 6+6 in its 8U models. A supply rating is not the server's draw, and none of these makers publishes a system power figure for its B200 model. NVIDIA rates its DGX B200 at 14.3 kW maximum. What the supplies deliver at your outlet voltage, and which feeds they need, is the subject of our guide to HGX B200 power and cooling in the data centre.

Air-cooled HGX B200 servers are 8U or 10U high. Supermicro gives the SYS-822GS-NBRT 133 kg net, ASUS the ESC NB8-E11 121 kg net without processors, memory or drives. The liquid-cooled versions fit in 4U: Supermicro's SYS-422GS-NBRT-LCC weighs 85 kg net with four 6,600 W supplies as 2+2. They take direct-to-chip cold plates on the GPUs and need a liquid loop at the rack; Supermicro adds "complete rack and onsite service are required" to its model description.

Drivers, CUDA and MIG on the B200

NVIDIA's CUDA GPU list gives the B200 compute capability 10.0. The release notes of CUDA 12.8 state that it "adds compiler support for" SM_100, with a Linux driver of 570.26 or later for that release, and NVIDIA's data-centre driver notes for 570.86.15 list the "NVIDIA HGX B200 8-GPU" as supported. MIG splits each B200 into up to seven instances; NVIDIA's MIG user guide (updated 4 November 2026) lists profiles from 1g.23gb to 7g.180gb and asks for R570 at 570.133.20 or later. The profile table and when MIG suits an eight-GPU server are in our article on B200 and B300 MIG profiles.

On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO. Which models fit into 1.4 TB with room for KV cache is worked out in LLMs on eight B200.

How we put an HGX B200 configuration together

We start from the workload and the site and fill the lines of the table above from them: the processor platform and memory from the size of the models and the data pipeline, the drives from the model store and scratch, the network cards from the number of servers, the power supplies and chassis from your feeds and your rack. The buying guide for an HGX B200 server explains the order and the quote, and our HGX B200 page what we supply. For cards and licences you can request our current NVIDIA price list.

We build each HGX B200 configuration with the maker for your project; tell us your rack position, feeds and number of servers together with the end user, the site and the intended use, and we answer with the configuration and the next steps.

FAQ

What are the HGX B200 specs?
Eight NVIDIA Blackwell SXM GPUs with 180 GB of HBM3e each, 1.4 TB per system, fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total, 72 PFLOPS of dense FP4 (144 sparse) and 296 TFLOPS of FP64, as NVIDIA's HGX page prints them. Each GPU is configurable up to 1,000 W.
How much memory does an HGX B200 server have?
1.4 TB of HBM3e on the GPUs as NVIDIA's HGX page prints it, 1,440 GB in the DGX B200 user guide, from eight times 180 GB. System memory is separate and set by the maker: Supermicro's SYS-822GS-NBRT takes up to 8 TB in 32 DIMM slots, the DGX B200 comes with 2 TB.
Which CPU does an HGX B200 server use?
That depends on the maker and model: Intel Xeon 6700/6500 or 6900 in newer Supermicro and Gigabyte models, AMD EPYC 9005 in Supermicro's AS-A126GS-TNBR, 4th or 5th Gen Xeon in the ASUS ESC NB8-E11 and older models. The DGX B200 uses two Xeon Platinum 8570.
Does the HGX B200 have built-in network cards?
We found no NVIDIA document that places network adapters on the HGX B200 board. B200 servers use separate cards, eight 400 Gb/s ConnectX-7 or BlueField-3 in Supermicro's brochure. The HGX B300 board carries eight 800 Gb/s ConnectX-8 SuperNICs.
What is a typical HGX B200 server configuration?
Two server processors, 2 to 4 TB of DDR5, two M.2 boot drives, eight NVMe data drives, eight 400G network cards and two DPUs, four to twelve redundant power supplies, in an 8U or 10U air-cooled or 4U liquid-cooled chassis. The exact lines depend on the workload and the site.
Which driver and CUDA version does the B200 need?
NVIDIA's CUDA list gives the B200 compute capability 10.0; CUDA 12.8 added compiler support for SM_100, and the R570 data-centre driver supports the HGX B200 8-GPU. MIG needs 570.133.20 or later.

We supply HGX B200 servers per project, configured with the maker line by line. Send us the models, the number of servers and the site, with the end user and the intended use, and we answer with a configuration. We reply within one business day.

Request a price
Talk to an expert

We reply within one business day

We use your details only to answer your enquiry; see our privacy policy.

request@eurokommerz.at
Jordangasse 7, 1010 Vienna