Eight RTX PRO 6000 Blackwell Server Edition cards or an HGX B200 server: PCIe or NVLink
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- Eight NVIDIA RTX PRO 6000 Blackwell Server Edition cards give 768 GB of GDDR7 as eight separate 96 GB pools on PCIe Gen5, with no NVLink; an HGX B200 server gives 1.4 TB of HBM3e with NVLink at 1.8 TB/s between all eight GPUs
- By our users-per-card rule that is 664.3 GiB against about 1,183 GiB for weights and KV cache; Llama 3.3 70B in FP8 runs as eight copies on both, with 96 conversations of 8K on the Server Edition server and 512 on the B200 board
- Each Server Edition card reads 1,597 GB/s and each B200 up to 8 TB/s, so a single user's token rate has a ceiling about five times higher on the B200 by our estimate
- The Server Edition splits into up to four MIG instances of 24 GB, is on NVIDIA's vGPU list from release 19.0 and has RT Cores and video engines for virtual workstations; the B200 splits into up to seven MIG instances of 23 GB
- An eight-card Server Edition server needs about 6.3 kW at the wall by our estimate; for HGX B200 servers no maker publishes a figure, and NVIDIA rates its DGX B200 with the same GPUs at 14.3 kW maximum
Supplied by Eurokommerz: HGX B200 servers Request a price →
RTX PRO 6000 Server Edition vs B200: eight PCIe cards or one HGX board
A server with eight NVIDIA RTX PRO 6000 Blackwell Server Edition cards holds 768 GB of GDDR7 in eight pools of 96 GB that talk over PCIe Gen5, draws about 6.3 kW by our estimate and suits many model copies, MIG slices and virtual workstations. An HGX B200 server holds 1.4 TB of HBM3e with NVLink at 1.8 TB/s between all eight B200 GPUs, reads memory about five times faster per GPU and suits one large model split eight ways, fine-tuning across GPUs and the highest throughput per server, in a class rated at 14.3 kW for NVIDIA's DGX B200.
Both machines use Blackwell GPUs, both compute in FP4, and NVIDIA AI Enterprise is licensed per GPU on both, eight licences either way. What separates them is the memory type, the link between the GPUs and the room each one needs. Our page on HGX B200 servers names the makers whose servers we supply; the card itself is on our RTX PRO 6000 page.
We build eight-card Server Edition servers to order and supply HGX B200 servers per project; tell us the models you serve, how many copies and whether the server also runs virtual desktops, and we answer which of the two your workload needs.
| ITEM | 8 × RTX PRO 6000 SE | HGX B200 |
|---|---|---|
| GPU memory | 8 × 96 GB GDDR7 with ECC | 8 × 180 GB HBM3e, 1.4 TB |
| Bandwidth per GPU | 1,597 GB/s | up to 8 TB/s |
| Link between GPUs | PCIe Gen5 x16, no NVLink | NVLink 5, 1.8 TB/s per GPU |
| FP32, all eight | 960 TFLOPS (8 × 120) | 600 TFLOPS |
| FP64, all eight | about 15 TFLOPS | 296 TFLOPS |
| Power per GPU | 300 to 600 W, configurable | up to 1,000 W |
| MIG per GPU | up to 4 | up to 7 |
| Compute capability | 12.0 | 10.0 |
NVIDIA RTX PRO 6000 Blackwell Server Edition product page and product brief SP-12355-001_v02 as used in our eight-card Server Edition guide (FP64 is our arithmetic at 1/64 of the FP32 rate, as in our A100 replacement article); NVIDIA's HGX platform page, HGX AI Factory reference architecture, HGX B200 carbon footprint summary and CUDA GPU list, read 27 November 2026; MIG counts from NVIDIA's MIG user guide (4 November 2026).
The Tensor Core rows are left out of the table on purpose. NVIDIA prints 2 PFLOPS of FP8 and 4 PFLOPS of FP4 for the Server Edition without saying whether they are sparse, while the HGX table gives the B200 board 36 PFLOPS of dense FP8 and 72 PFLOPS of dense FP4, 4.5 and 9 PFLOPS per GPU by our division. The datasheets therefore do not settle the ratio per card; the memory bandwidth and the link between the GPUs decide most LLM serving anyway.
Many model copies or one large model
The useful question is how a model is laid out on the eight GPUs. Our users-per-card rule takes 90 per cent of the memory per GPU and subtracts 3 GiB: 0.9 × 95.6 − 3 = 83.0 GiB on a Server Edition card, whose driver reports 95.6 GiB, and 664.3 GiB for eight, as our guide to LLMs on eight Server Edition cards derives. For the B200 we have no driver-reported figure, so we read 180 GB as 10⁹ bytes and get 147.9 GiB per GPU and about 1,183 GiB for eight, an upper bound by our estimate.
| SERVING PATTERN | 8 × RTX PRO 6000 SE | HGX B200 |
|---|---|---|
| Copy per GPU, up to 80 GiB | eight copies, 83.0 GiB each | eight copies, 147.9 GiB each |
| Model of 80 to 330 GiB | TP=2 or TP=4 over PCIe | one, two or four GPUs on NVLink |
| Model of 330 to 660 GiB | TP=8 over PCIe, little cache | TP=4 or TP=8 on NVLink |
| Model above 664 GiB | does not fit | up to about 1,183 GiB |
| Isolated slices | 32 MIG instances of 24 GB | 56 MIG instances of 23 GB |
| Virtual desktops, rendering | vGPU, RT Cores, NVENC | not listed by NVIDIA |
our estimate by the users-per-card rule; MIG profiles from NVIDIA's MIG user guide (4 November 2026); vGPU from NVIDIA's vGPU documentation as quoted in our Server Edition vGPU profiles article. NVIDIA's HGX B200 column lists Tensor Core, memory, NVLink and network figures and nothing on graphics.
Three examples from our model guides show where the line falls. gpt-oss-120b in MXFP4, 65.2 GB, fits one GPU of either server, so both run eight copies and the link between the GPUs does not matter. DeepSeek-V3.2 in FP8, 690 GB, fits eight Server Edition cards with about 21.7 GiB left for cache across the whole server, room for only a few conversations, while the B200 board keeps about 540 GiB. GLM-5.3 in FP8, 703.7 GiB of weights, does not fit the Server Edition server at all and leaves about 479 GiB on the B200. Above about 1,180 GiB of weights neither server is enough; that is the case for HGX B300, compared in HGX B200 now or HGX B300 later.
Llama 3.3 70B in FP8 and NVFP4 on both servers
Llama 3.3 70B is the model most companies name first, and it fits one GPU of either server. NVIDIA's FP8 checkpoint takes 67.7 GiB, the NVFP4 checkpoint 39.8 GiB of weights, and each conversation of 8,192 tokens 1.25 GiB of FP8 cache.
| LLAMA 3.3 70B, 8K | RTX PRO 6000 SE | B200 |
|---|---|---|
| FP8 weights, one copy | 12 conversations | 64 conversations |
| FP8, eight copies | 96 | 512 |
| NVFP4 weights, one copy | 34 conversations | 86 conversations |
| NVFP4, eight copies | 272 | 688 |
| One-user ceiling, FP8 | about 23 tokens/s | about 113 tokens/s |
| One-user ceiling, NVFP4 | about 39 tokens/s | about 197 tokens/s |
our estimate by the users-per-card rule, conversations of 8,192 tokens with an FP8 KV cache of 1.25 GiB, whole conversations per copy; ceilings are bandwidth divided by 70.6 GB (FP8) or 40.6 GB (NVFP4) read per token, upper bounds by our estimate; checkpoint sizes from our guide to how many users one RTX PRO 6000 serves.
On the Server Edition card the 70B model in FP8 leaves 15.3 GiB for cache, so FP4 is what makes the card useful for this model: the NVFP4 checkpoint almost triples the conversations per card, at the accuracy cost NVIDIA's model card reports, as our guide to NVFP4 models for the RTX PRO 6000 sets out. On the B200 the extra memory makes FP8 workable for several dozen users per GPU, and NVFP4 adds a third on top. The one-user ceiling follows bandwidth: 8 TB/s against 1,597 GB/s, five times by our division.
Tensor parallelism over PCIe Gen5 and over NVLink
NVIDIA's product brief SP-12355-001_v02 lists NVLink as "Not supported" for the Server Edition, so a model split over several cards exchanges its all-reduces over PCIe Gen5 x16 at 128 GB/s per card. On the HGX B200 the same traffic runs over NVLink 5 at 1.8 TB/s per GPU, about 14 times as much by our division, through NVIDIA's NVLink switches.
Tensor parallelism runs two all-reduces per layer in the forward pass, so the link sets the cost of every generated token. On eight Server Edition cards vLLM uses its own custom all-reduce for two PCIe-only GPUs and leaves four and eight to NCCL by default; since vLLM 0.30.0 an opt-in FlashInfer PCIe all-reduce exists for TP of 2, 4 and 8. Our article on the RTX PRO 6000 without NVLink gives the layouts per model size: copies where they fit, TP=2 up to about 150 GiB of weights, TP=4 up to about 310 GiB. On the B200 board TP=8 is the plain layout, and training jobs that shard over eight GPUs, with FSDP or ZeRO-3, keep their gradient and parameter traffic on NVLink.
MIG slices, vGPU and graphics
A server that hosts many small services, notebooks or desktops is sized by the slices it offers. NVIDIA's MIG user guide (updated 4 November 2026) gives the B200 up to seven instances of 1g.23gb, four of 1g.45gb, three of 2g.45gb, two of 3g.90gb and one of 4g.90gb or 7g.180gb, so eight GPUs offer up to 56 instances; the driver minimum is R570 570.133.20. The Server Edition splits into up to four instances of 24 GB, two of 48 GB or one of 96 GB, 32 instances for eight cards, with a driver of 575.51.03 or later; our B200 and B300 MIG profiles and RTX PRO 6000 MIG profiles list the sizes.
For virtual machines the Server Edition is the card of the two to plan with. It is on NVIDIA's vGPU list from release 19.0, its MIG-backed vGPU types include graphics as well as compute, and NVIDIA's vPC sizing guide gives up to 48 desktops per card, as our article on Server Edition vGPU profiles shows. Each card also carries 188 RT Cores, four NVENC and four NVDEC, so the same server can render, encode video and host virtual workstations next to inference. On VMware vSphere the Blackwell Server Editions need ESXi 8.0 U3 P06 or later.
Power per server: about 6 kW or about 14 kW
| ITEM | 8 × RTX PRO 6000 SE | HGX B200 SERVER |
|---|---|---|
| GPU power | up to 4.8 kW | up to 8 kW |
| Server power | about 6.3 kW, our estimate | DGX B200: 14.3 kW max. |
| Example chassis | ASUS ESC8000A-E13X, 4U, 45 kg net without CPUs, memory, drives | Supermicro SYS-822GS-NBRT, 8U, 133 kg net |
| Feed per side, our plan | 400 V 16 A three-phase | 400 V 32 A three-phase |
| In a 20 kW rack | three servers | one server |
our estimate for the Server Edition server (eight cards at 600 W, two AMD EPYC 9555, 15 per cent for the rest); ASUS ESC8000A-E13X datasheet weight as in our article on the ASUS ESC8000 for the RTX PRO 6000 Server Edition; NVIDIA DGX B200 user guide and Supermicro SYS-822GS-NBRT product page, read 27 November 2026; feeds at 80 per cent (8.87 kW at 16 A, 17.74 kW at 32 A) from our guide to GPU server power on 16 A, 32 A and three-phase.
The Server Edition server is already a three-phase machine: at about 6.3 kW it exceeds the 5.89 kW of a 230 V 32 A circuit planned at 80 per cent. Because the card's power limit is configurable down to 300 W, a room with a tight feed can run it capped, as our article on Server Edition power at 600, 450 and 300 W works out.
For HGX B200 servers the makers publish no system figure on the pages we read. The GPU modules alone are rated up to 1,000 W each, 8 kW together, and NVIDIA rates its own DGX B200 at 14.3 kW maximum. Supermicro's 8U model has six 6,600 W supplies in 3+3; liquid-cooled 4U versions exist, and Supermicro states that its SYS-422GS-NBRT-LCC requires a complete rack and onsite service. The room for this class is described in HGX B200 server power and cooling.
Budget class and what each quote contains
We publish no prices, and the two servers sit in different budget classes. An eight-card Server Edition server is the largest of the PCIe configurations we build to order; its quote lists the cards, two processors, memory, NVMe drives, network cards, the chassis with its supplies and the licences. An HGX B200 server is a project order; its quote lists the server with the GPU board, processors, memory, storage, network cards, the warranty level and the delivery terms. Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) names eight single-port ConnectX-7 or BlueField-3 cards at up to 400 Gb/s for its HGX B200 server, one per GPU, so the cluster network is a line of its own. How to compare such quotes line by line is explained in our guide to GPU server quotes.
For an HGX B200 order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it, as our guide to the end-user certificate for NVIDIA GPUs describes. We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project, with warranty and service from the server maker, handled through us. The Server Edition server is assembled and tested before delivery, with manufacturer warranty on every component. On request we pre-install the operating system, drivers, CUDA and a container runtime on either, with remote setup by our engineering partner Vixen.UNO. Companies comparing both routes can request our current NVIDIA price list.
Choosing between the two
| WORKLOAD | BETTER FIT | WHY |
|---|---|---|
| Many copies, models to 70B | either; SE server at 6.3 kW | each copy fits one GPU |
| VDI, rendering, video | 8 × RTX PRO 6000 SE | vGPU graphics, RT Cores, NVENC |
| One model, 330 to 660 GiB | HGX B200 | TP=8 on NVLink, more cache |
| One model, 660 to 1,180 GiB | HGX B200 | does not fit the SE server |
| Fine-tuning on eight GPUs | HGX B200 | gradients stay on NVLink |
| FP64 solvers | HGX B200 | 296 against about 15 TFLOPS |
| FP32 rendering or simulation | 8 × RTX PRO 6000 SE | 960 against 600 TFLOPS |
| 16 A three-phase positions | 8 × RTX PRO 6000 SE | about 6.3 kW per server |
our reading of the figures above.
Between the two lies the eight-card H200 NVL server with 1,128 GB in two NVLink domains, compared with the B200 board in HGX B200 vs eight H200 NVL. The same PCIe-or-NVLink question one generation up is in DGX B300 vs an eight-card RTX PRO 6000 server, and the users per model on 1.4 TB are in LLMs on an HGX B200 server. If you are unsure on which side of 664 GiB your models fall, send us the model list with precision and context length, and we reply with the fit on both servers.
FAQ
RTX PRO 6000 vs B200: which is faster for LLM inference?
Can eight RTX PRO 6000 Server Edition cards replace an HGX B200 server?
Does the RTX PRO 6000 Server Edition have NVLink?
How many users can eight RTX PRO 6000 Server Edition cards serve compared with an HGX B200?
Which needs more power, 8× RTX PRO 6000 Server Edition or HGX B200?
Is a PCIe or an HGX server better for VDI and virtual workstations?
Where can we buy eight RTX PRO 6000 Server Edition or an HGX B200 server in the EU?
Send us your models, how many copies you run, the desktops if any and the feed of the rack position. We answer with the fit on eight RTX PRO 6000 Server Edition cards and on an HGX B200 server. We reply within one business day.