HGX B200 vs a server with eight H200 NVL: memory, NVLink, FP4 and power
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- An HGX B200 server carries eight B200 GPUs with 180 GB of HBM3e each, 1.4 TB as NVIDIA prints it, all joined by NVLink at 1.8 TB/s per GPU; eight H200 NVL hold 1,128 GB in two NVLink domains of four cards with PCIe Gen5 between them
- By our users-per-card rule the HGX B200 leaves about 1,183 GiB for weights and KV cache against 986.9 GiB, and Llama 3.3 70B in FP8 holds 892 conversations of 8K as one TP=8 copy against 735 on the H200 NVL server as TP=4 × PP=2
- NVIDIA's HGX table gives the HGX B200 36 PFLOPS of dense FP8 and 72 PFLOPS of dense FP4; eight H200 NVL come to about 13.4 PFLOPS of dense FP8 by our arithmetic and have no FP4 arithmetic
- The B200 board lists 296 TFLOPS of FP64; eight H200 NVL list 240 TFLOPS of FP64 and 480 TFLOPS on their FP64 Tensor Cores
- The eight GPUs draw up to 8 kW on the B200 board and up to 4.8 kW as H200 NVL cards; NVIDIA rates its DGX B200 at 14.3 kW maximum, and we estimate about 6.3 kW at the wall for the H200 NVL server
Supplied by Eurokommerz: HGX B200 servers Request a price →
B200 vs H200 NVL: two ways to build an eight-GPU server
An HGX B200 server holds eight NVIDIA B200 GPUs with 1.4 TB of HBM3e on one NVLink fabric, reads up to 8 TB/s per GPU and computes in FP4; a server with eight NVIDIA H200 NVL holds 1,128 GB at 4.8 TB/s per card in two NVLink domains of four, with no FP4 arithmetic. The B200 board is the platform for models that must be split over all eight GPUs, for NVFP4 serving and for training across eight GPUs; the H200 NVL server serves models of up to about 490 GiB per copy in a rack position of about 6.3 kW by our estimate.
The two machines are built differently. HGX B200 is NVIDIA's baseboard with eight B200 SXM modules and NVLink 5 switches, which server makers build into their own chassis, such as Supermicro's 8U SYS-822GS-NBRT. The H200 NVL is a dual-slot PCIe card of up to 600 W that goes into a standard GPU server and is joined to its neighbours by NVLink bridges. Our page on HGX B200 servers lists the makers whose servers we supply.
We supply HGX B200 servers per project and build eight-card H200 NVL servers to order; send us your models, their precision and the rack position you have, and we answer with the layout each model would run on both servers.
| SPECIFICATION | 8 × H200 NVL SERVER | HGX B200 SERVER |
|---|---|---|
| GPU memory | 1,128 GB HBM3e, 141 GB per card | 1.4 TB HBM3e, 8 × 180 GB |
| Usable by our rule | 986.9 GiB | about 1,183 GiB |
| Memory bandwidth per GPU | 4.8 TB/s | up to 8 TB/s |
| GPU to GPU | NVLink 900 GB/s in 2 × 4, PCIe between | NVLink 1.8 TB/s, all eight |
| FP8 Tensor, dense | about 13.4 PFLOPS | 36 PFLOPS (72 sparse) |
| FP4 Tensor, dense | no FP4 arithmetic | 72 PFLOPS (144 sparse) |
| FP64 | 240 TFLOPS, 480 FP64 Tensor | 296 TFLOPS |
| GPU power | 8 × up to 600 W | 8 × up to 1,000 W |
| Compute capability | 9.0 | 10.0 |
NVIDIA's HGX platform page (HGX B200 column; FP8 printed sparse with "Dense is ½ sparse spec shown", FP4 printed sparse and dense) and HGX AI Factory reference architecture (180 GB and up to 8 TB/s per GPU), NVIDIA's HGX B200 carbon footprint summary (up to 1,000 W per GPU) and CUDA GPU list, all read 27 November 2026; H200 NVL figures from NVIDIA's H200 page as used in our comparison of eight H200 NVL and a DGX B300 (dense FP8 is our halving of the sparse 3,341 TFLOPS per card). Usable memory is our estimate, explained below.
The HGX H200 board with H200 SXM modules is a third design with the same 141 GB per GPU and NVSwitch across all eight; our comparison of H200 NVL and H200 SXM covers it.
Memory: one pool of 1.4 TB or two domains of 564 GB
We size with our users-per-card rule: 90 per cent of the memory per GPU, less 3 GiB for CUDA graphs and activations, and whatever the weights leave holds KV cache. For the H200 NVL the driver reports 140.4 GiB, which gives 123.4 GiB per card and 986.9 GiB for eight, as our guide to the eight-card H200 NVL server derives. For the B200 we have no driver-reported figure, so we read the 180 GB per GPU as 10⁹ bytes, 167.6 GiB, and get 0.9 × 167.6 − 3 = 147.9 GiB per GPU and about 1,183 GiB for eight. That is an upper bound by our estimate; the driver on the delivered system decides.
| MODEL | WEIGHTS | LEFT, 8 × H200 NVL | LEFT, HGX B200 |
|---|---|---|---|
| Llama 3.3 70B, FP8 | 72.7 GB, 67.7 GiB | 919.2 GiB | 1,115.3 GiB |
| Qwen3-235B-A22B-2507, FP8 | 236 GB, 219.8 GiB | 767.1 GiB | 963.2 GiB |
| DeepSeek-V3.2, FP8 | 690 GB, 642.6 GiB | 344.3 GiB | 540.4 GiB |
| DeepSeek-V4-Pro, FP4 + FP8 | 892.7 GB, 831.4 GiB | 155.5 GiB | 351.6 GiB |
| Kimi-K2-Instruct-0905, FP8 | 1,029 GB, 958.3 GiB | 28.5 GiB | 224.7 GiB |
| Kimi-K3.1-Pro, MXFP4 | 1,561.3 GB, 1,454.1 GiB | does not fit | does not fit |
our estimate by the users-per-card rule, memory left for KV cache on the whole server; weights as Hugging Face repository sizes in our model guides (September to November 2026), as listed in our eight-card H200 NVL guide.
The first two rows fit both servers with room to spare, so the choice there turns on users and power. From DeepSeek-V3.2 down the difference grows: about 196 GiB more cache on the B200 board in every row, and the Kimi K2 checkpoint in FP8, which leaves about one conversation of 32K on eight H200 NVL, keeps 224.7 GiB for cache on the B200. DeepSeek-V4-Pro fits the H200 NVL server only because its FP4 expert weights stay in 4-bit in memory while Hopper computes them at higher precision; the B200 computes them in FP4. The last row fits neither and belongs on HGX B300, as our comparison of HGX B200 now or HGX B300 later explains. Model by model, the users per layout on 1.4 TB are in our guide to LLMs on an HGX B200 server.
TP=8 on one NVLink fabric or TP=4 × PP=2 across two
The memory figures above are totals. How the GPUs are connected decides how a model may be split. NVIDIA's NVLink bridge for the H200 NVL joins two or four cards at 900 GB/s per GPU, and Gigabyte supports eight cards in its G494-SB4-AAP2 "arranged as two 4-GPU sets, each with a 4-way NVLink bridge", so the server has two domains of four with PCIe Gen5 at 128 GB/s between them. On the HGX B200 board, NVLink 5 switches connect all eight GPUs at 1.8 TB/s each, 14.4 TB/s in total by NVIDIA's HGX table.
For Llama 3.3 70B in FP8, with an FP8 cache of 1.25 GiB per conversation of 8,192 tokens, the layouts compare like this by our rule.
| LAYOUT | 8 × H200 NVL | HGX B200 |
|---|---|---|
| Eight copies, one per GPU | 352 | 512 |
| Two copies of four GPUs | 680, one per NVLink domain | 838 |
| One copy on eight GPUs | 735 as TP=4 × PP=2 | 892 as TP=8 |
our estimate by the users-per-card rule, conversations of 8,192 tokens at full length with an FP8 KV cache; H200 NVL rows as in our eight-card H200 NVL guide.
For a 70B model the topology costs the H200 NVL server little, because each copy stays inside one NVLink bridge. It matters for models of more than about 490 GiB, which must span both domains. OVHcloud's guide for its eight-card H200 NVL instances, as quoted in our eight-card H200 NVL guide, advises against a tensor-parallel size of eight and runs such models as two pipeline stages of TP=4; the bridge rules are in our article on the H200 NVL NVLink bridge, 2-way or 4-way. On the B200 board TP=8 is the plain layout, expert parallelism for large mixture-of-experts models stays on NVLink, and a training job that shards over eight GPUs exchanges its gradients over the switches without a PCIe hop.
FP8, FP4 and FP64 throughput
NVIDIA prints most HGX Tensor Core figures with sparsity and adds that dense is half. For the HGX B200 that gives 36 PFLOPS of dense FP8, 4.5 PFLOPS per GPU by our division. NVIDIA lists 3,341 TFLOPS of FP8 with sparsity per H200 NVL, about 1,671 dense, so eight cards reach about 13.4 PFLOPS dense: the B200 board has 2.7 times the dense FP8 rate by our arithmetic.
FP4 is the larger difference. The HGX table gives the HGX B200 144 PFLOPS of FP4 sparse and 72 PFLOPS dense. Hopper has no FP4 arithmetic, so an NVFP4 checkpoint built for Blackwell runs on the H200 NVL only as a weight-only format, stored in 4 bits and computed at 16-bit, as our guide to FP4 models on H200 NVL and Ada GPUs describes. Compare the dense columns: NVFP4 checkpoints do not use the structured sparsity behind the larger figure.
Double precision runs closer than many buyers expect. NVIDIA's HGX table prints one figure, 296 TFLOPS, in its row for FP64 and FP64 Tensor Core on the HGX B200, 37 TFLOPS per GPU by our division. NVIDIA rates each H200 NVL at 30 TFLOPS of FP64 and 60 TFLOPS on its FP64 Tensor Cores, 240 and 480 for eight cards. Both machines carry double precision, unlike the HGX B300 with 10 TFLOPS for all eight GPUs; our FP64 GPU server comparison covers the codes.
Memory bandwidth sets the ceiling for one user's token rate: bandwidth divided by the bytes read per token. For Llama 3.3 70B in FP8, which reads about 70.6 GB per token, that is about 113 tokens per second on one B200 at 8 TB/s and about 68 on one H200 NVL at 4.8 TB/s; both are upper bounds by our estimate.
Power, cooling and the rack position
| ITEM | 8 × H200 NVL SERVER | HGX B200 SERVER |
|---|---|---|
| GPU power | up to 4.8 kW | up to 8 kW |
| Server power | about 6.3 kW, our estimate | none published by makers; DGX B200 14.3 kW max. |
| Height, example | 4U, Supermicro SYS-422GA-NRT | 8U, Supermicro SYS-822GS-NBRT |
| Power supplies, example | per maker | 6 × 6,600 W, 3+3 |
| Weight, example | per maker | 133 kg net |
| Inlet air, example | 25 °C (Gigabyte G494) to 35 °C (Supermicro SYS-422GA-NRT), eight cards | 10 to 35 °C (Supermicro) |
| Feed per side, our plan | 400 V 16 A three-phase, 8.87 kW | 400 V 32 A three-phase, 17.74 kW |
NVIDIA's HGX B200 carbon footprint summary (up to 1,000 W per GPU) and DGX B200 user guide (14.3 kW maximum), read 27 November 2026; Supermicro's SYS-822GS-NBRT product page and datasheet page, read 27 November 2026; H200 NVL server estimate as in our eight-card H200 NVL guide; Gigabyte G494-SB4-AAP2 and Supermicro SYS-422GA-NRT bridge and inlet conditions as in our guide to H200 NVL compatible servers; feed capacities at 80 per cent from our guide to GPU server power on 16 A, 32 A and three-phase.
No server maker publishes a system power figure for an HGX B200 server on the pages we read. The nearest NVIDIA figure is its own DGX B200, rated at 14.3 kW maximum with the same eight GPUs, and the eight B200 modules alone account for up to 8 kW. Supermicro's six 6,600 W supplies in 3+3 deliver 6,500 W each at 230 to 238.9 V, so the three working supplies offer 19.5 kW by our arithmetic; that is supply capacity and says nothing about the draw. The H200 NVL server, at about 6.3 kW by our estimate, fits a 400 V 16 A three-phase position on each of the A and B feeds, and two of them fit a 20 kW rack with room for switches. Two HGX B200 servers at the DGX B200's rating come to 28.6 kW, far above the 8 to 15 kW a classic enterprise rack is designed for, as our guide to GPU rack power and cooling notes. The details are in our article on HGX B200 server power and cooling.
MIG, CUDA and licences
Both GPUs split into up to seven MIG instances. NVIDIA's MIG user guide (updated 4 November 2026) lists 1g.23gb up to seven times on the B200 and 1g.18gb up to seven times on the H200, so both servers offer up to 56 isolated instances, those on the B200 with about 28 per cent more memory each. The guide's driver minimums are R570 570.133.20 for the B200 and R550 550.90.07 for the H200. The full list of profiles is in our article on B200 and B300 MIG profiles.
The software step is larger on the B200. NVIDIA's CUDA list gives it compute capability 10.0 against 9.0 for the H200 NVL, and NVIDIA's release notes for CUDA 12.8 add compiler support for SM_100. Kernels compiled only for Hopper do not run on Blackwell as machine code, so images and extensions need a build that contains code for 10.0, as our article on the no kernel image error on Blackwell explains with NVIDIA's compatibility rules.
NVIDIA's licensing includes a five-year NVIDIA AI Enterprise subscription with each H200 NVL, counted from the board's shipment to the server maker plus 90 days. For an HGX B200 server the quote states the licences per GPU, eight for eight GPUs; NVIDIA AI Enterprise licences come on the same invoice as the server.
Which server fits which workload
- A company assistant or RAG service on 70B to 235B models: both serve it. The H200 NVL server does it at about 6.3 kW; the B200 board holds about 21 to 23 per cent more conversations for Llama 3.3 70B as one or two copies.
- Models of more than about 490 GiB at interactive speed, or MoE models that need TP=8 or expert parallelism: the HGX B200, which keeps the traffic on NVLink.
- NVFP4 checkpoints at full speed: the HGX B200.
- FP64 simulation next to AI: either server. The H200 NVL server lists 240 TFLOPS of FP64 at about 6.3 kW, the HGX B200 296 TFLOPS in a class rated at 14.3 kW for the DGX B200.
- Full fine-tuning of 70B models and training across eight GPUs: the HGX B200.
- A room with 16 A three-phase positions and racks planned for 20 kW: the H200 NVL server.
- Open models above about 1,180 GiB of weights, such as Kimi-K3.1-Pro: neither; HGX B300, compared in DGX B300 vs DGX B200 vs HGX B300.
Against PCIe cards with FP4 and no NVLink, our comparison of eight RTX PRO 6000 Server Edition cards or an HGX B200 server sets out the other route, and a company that is retiring an H100 system finds the three successors in replacing an 8-GPU H100 SXM server. The H200 NVL server is also set against a DGX B300 in our eight H200 NVL vs DGX B300 comparison.
How we supply each server
The H200 NVL server is built to order. Our training node has eight H200 NVL cards with two 4-way NVLink bridges, two AMD EPYC processors, 2.3 TB of DDR5 ECC, eight NVMe drives and 400G networking, assembled and tested before delivery, with manufacturer warranty on every component.
HGX B200 servers we supply per project from Supermicro, ASUS, Gigabyte, HPE and Lenovo: the same eight GPUs on the same NVIDIA HGX board as the DGX B200, with warranty and service from the server maker, handled through us. If you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. For an HGX B200 order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration.
On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO. Your data-centre staff or colocation provider rack the server, and hardware service on site comes from the server maker as configured in the quote. Companies that plan several purchases can request our current NVIDIA price list. Write to us with the models, the users at peak and the feed of the rack position, and we reply with both configurations side by side.
FAQ
B200 vs H200: which is faster?
How much more memory does an HGX B200 server have than eight H200 NVL?
Can eight H200 NVL run a model with TP=8?
Does the H200 NVL support FP4?
Is the B200 or the H200 NVL better for FP64?
How much power does an HGX B200 server need compared with an 8× H200 NVL server?