BLOG · COMPARISON · · UPDATED

Replacing an 8-GPU H100 SXM server or a DGX H100: HGX B200, HGX B300 or eight H200 NVL

Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software

IN BRIEF
  • NVIDIA's DGX H100 user guide describes eight H100 SXM GPUs with 640 GB in total, 8U, 130.45 kg and a maximum of 10.2 kW from six 3.3 kW supplies; HGX H100 servers from other makers carry the same eight-GPU board
  • An HGX B200 server has 1.4 TB of HBM3e, 2.3 times the dense FP8 rate of eight H100 SXM by our arithmetic (36 against about 15.8 PFLOPS) and FP4, with NVLink across all eight GPUs as before; NVIDIA's DGX B200 is rated at 14.3 kW maximum, 4.1 kW more than the DGX H100
  • An HGX B300 server has 2.1 TB and 108 PFLOPS of dense FP4 but only 10 TFLOPS of FP64 for all eight GPUs, against 272 TFLOPS for eight H100 SXM by our multiplication
  • Eight H200 NVL give 1,128 GB at about 6.3 kW by our estimate and keep compute capability 9.0, so Hopper software runs unchanged; they lose NVLink across all eight GPUs and have about 15 per cent less dense FP8 than eight H100 SXM
  • The B200 is compute capability 10.0 and needs CUDA 12.8 or later and an R570 driver or newer; cubins built only for Hopper do not run on it, so images and extensions need a rebuild

Supplied by Eurokommerz: HGX B200 servers  Request a price →

What replaces an 8-GPU H100 SXM server

An eight-GPU H100 SXM server, a DGX H100 or an HGX H100 server from another maker, is replaced like for like by an HGX B200 server: eight GPUs on one NVLink fabric again, 1.4 TB of HBM3e instead of 640 GB, 2.3 times the dense FP8 rate and FP4, in a power class of about 14 kW instead of 10.2 kW. An HGX B300 server is the step for models above 1.2 TB and FP4 at scale, and a server with eight H200 NVL is the step that keeps Hopper software and cuts the power to about 6.3 kW by our estimate, at the cost of the eight-GPU NVLink fabric.

This is a whole-server replacement: the H100 SXM modules sit on a baseboard with NVSwitch and are not exchanged for newer modules or PCIe cards. We do not supply the H100 or the DGX H100. We supply new HGX B200 servers and HGX B300 servers per project, and we build eight-card H200 NVL servers to order.

The order of an HGX server runs through a project review: we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it, as our guide to the end-user certificate for NVIDIA GPUs explains. Send us what runs on your H100 system today and the rack position it uses, and we answer with the successor that fits that position.

The H100 system you run today

SYSTEMPOWERHEIGHT, DEPTHWEIGHTSUPPLIES
NVIDIA DGX H10010.2 kW max.8U, 897.1 mm130.45 kg max.6 × 3.3 kW, 4+2
Supermicro SYS-821GE-TNHRnot published8U, 843.28 mm75.3 kg net6 × 3,000 W, 4+2
ASUS ESC N8-E11not published7U, 885 mm113 kg net6 × 3,000 W, 4+2

NVIDIA DGX H100/H200 user guide, "Introduction to NVIDIA DGX H100/H200 Systems" (updated 17 October 2026); Supermicro SYS-821GE-TNHR product page; ASUS ESC N8-E11 datasheet (29 August 2024); all read 27 November 2026.

In their H100 configuration all three carry eight H100 SXM GPUs with 80 GB each. NVIDIA's H100 page lists the SXM module with 3.35 TB/s of memory bandwidth, NVLink at 900 GB/s, up to 700 W configurable, 34 TFLOPS of FP64 and 67 on FP64 Tensor Cores, and 3,958 TFLOPS of FP8 with sparsity. For eight GPUs that makes 640 GB of HBM3, about 15.8 PFLOPS of dense FP8 by our halving and 272 TFLOPS of FP64 by our multiplication.

H100 against its three successors

ITEM8 × H100 SXMHGX B200HGX B3008 × H200 NVL
GPU memory640 GB1.4 TB2.1 TB1,128 GB
Usable by our rule512.4 GiBabout 1,183 GiBabout 1,786 GiB986.9 GiB
Bandwidth per GPU3.35 TB/sup to 8 TB/sup to 8 TB/s4.8 TB/s
NVLink per GPU900 GB/s, all eight1.8 TB/s, all eight1.8 TB/s, all eight900 GB/s in 2 × 4
FP8, dense, all GPUsabout 15.8 PFLOPS36 PFLOPS36 PFLOPSabout 13.4 PFLOPS
FP4, dense, all GPUsnone72 PFLOPS108 PFLOPSnone
FP64, all GPUs272 TFLOPS296 TFLOPS10 TFLOPS240 TFLOPS
Cluster port per GPU400 Gb/s (DGX)400 Gb/s cards800 Gb/s on boardper configuration
Compute capability9.010.010.39.0

NVIDIA H100 product page and DGX H100/H200 user guide; NVIDIA HGX platform page (FP8 printed sparse with "Dense is ½ sparse spec shown", FP4 printed sparse and dense, FP64 row "FP64 / FP64 Tensor") and HGX AI Factory reference architecture; NVIDIA CUDA GPU list; Supermicro "NVIDIA Blackwell Solutions" brochure (December 2025) for the B200 network cards; all read 27 November 2026. H200 NVL from NVIDIA's H200 page as used in our eight-card H200 NVL guide. H100 and H200 NVL FP8 are our halving of NVIDIA's sparse figures; FP64 on FP64 Tensor Cores: 536 TFLOPS for eight H100 SXM, 480 for eight H200 NVL.

The HGX B200 is the closest successor in character. It keeps all eight GPUs on NVLink with switches and doubles the link to 1.8 TB/s per GPU; memory per GPU rises from 80 to 180 GB, bandwidth 2.4 times, and FP64 stays in the same range, 296 against 272 TFLOPS.

The HGX B300 goes further on memory and FP4 and drops FP64 to 10 TFLOPS for all eight GPUs, which rules it out for double-precision work.

The H200 NVL server adds memory and leaves the compute where it was: 1.76 times the memory of the H100 system and 1.43 times the bandwidth per GPU, about 15 per cent less dense FP8, and NVLink bridges of at most four cards, so the eight cards form two domains with PCIe Gen5 between them, as our comparison of H200 NVL and H200 SXM explains.

The same 70B service before and after

Our users-per-card rule takes 90 per cent of the memory per GPU and subtracts 3 GiB. We have no driver-reported figure for the H100 SXM or the B200, so we start from the listed 80 and 180 GB read as 10⁹ bytes, an upper bound: 0.9 × 74.5 − 3 = 64.1 GiB per H100 and 147.9 GiB per B200. For the B300 we use 223.3 GiB per GPU and for the H200 NVL 123.4 GiB per card, as on our other pages.

LLAMA 3.3 70B, FP88 × H100 SXMHGX B200HGX B3008 × H200 NVL
Eight copiesdoes not fit one GPU512992352
Two copies of four GPUs3008381,320680
One copy on eight GPUs3558921,374735 as TP=4 × PP=2

our estimate by the users-per-card rule, conversations of 8,192 tokens at full length with an FP8 KV cache of 1.25 GiB; weights 67.7 GiB (NVIDIA's FP8 checkpoint, as in our guide to how many users one GPU serves).

The 67.7 GiB of FP8 weights exceed the 64.1 GiB of one H100 SXM by our rule, so on the H100 system the model runs split over at least two GPUs. On the B200 it fits one GPU with room for 64 conversations, and the same 70B service holds about 2.5 to 2.8 times as many conversations as on the H100 system in the layouts both can run.

Some larger models fit only after the change. DeepSeek-V3.2 in FP8, 690 GB, is larger than the 512.4 GiB of eight H100 SXM by our rule and leaves about 540 GiB for cache on the HGX B200. Kimi-K3.1-Pro, 1,561.3 GB in MXFP4, fits only the HGX B300, with about 332 GiB to spare. The model-by-model figures are in our guide to LLMs on an HGX B200 server.

Power, cooling and the existing rack position

The rack position of a DGX H100 was planned for 10.2 kW. That already exceeds the 8.87 kW a 400 V 16 A three-phase feed carries at our 80 per cent margin, so such positions usually have 400 V 32 A three-phase feeds, 17.74 kW each, as our guide to GPU server power on 16 A, 32 A and three-phase sets out.

SUCCESSORPOWERHEIGHT, DEPTHWEIGHTSUPPLIES
NVIDIA DGX B200, reference14.3 kW max.10U, 897.1 mm142.4 kg max.6 × 3.3 kW
Supermicro SYS-822GS-NBRTnot published8U, 950 mm133 kg net6 × 6,600 W, 3+3
ASUS ESC NB8-E11, B200not published10U, 885 mm121 kg net, without CPU, memory, drives6 × 3,000 W, 5+1
Supermicro SYS-822GS-NB3RTnot published8U, 950 mm119 kg net6 × 6,600 W, 3+3
8 × H200 NVL serverabout 6.3 kW4Uper makerper maker

NVIDIA DGX B200 user guide (updated 17 October 2026); Supermicro product pages for the SYS-822GS-NBRT (HGX B200) and SYS-822GS-NB3RT (HGX B300); ASUS ESC NB8-E11 datasheet (29 May 2025); all read 27 November 2026. H200 NVL server: our estimate with two AMD EPYC 9555, as in our eight-card H200 NVL guide.

The GPUs alone grow from 8 × 700 W, 5.6 kW, to 8 × 1,000 W, 8 kW, on the B200 board, and to 8 × 1,100 W, 8.8 kW, on HGX B300 by Supermicro's figure. No maker publishes a system figure for its HGX B200 server on the pages we read; NVIDIA's DGX B200 with the same GPUs is rated at 14.3 kW maximum, 4.1 kW or about 40 per cent above the DGX H100. Supermicro's HGX B300 datasheet gives a node maximum of 15 kW, and NVIDIA's DGX B300 user guide (10 November 2026) gives 14.5 kW with a 15 kW system maximum. Each of these still fits one 400 V 32 A three-phase feed per side at our margin; a rack that held two DGX H100 at 20.4 kW needs about 28.6 to 30 kW for two B200 or B300 successors on these figures.

At the 160 CFM per kW of our GPU rack power and cooling guide, 10.2 kW needs about 1,630 CFM of air and 14.3 kW about 2,290 CFM by our estimate. The DGX H100 accepts inlet air of 5 to 30 °C; the DGX B200 and Supermicro's B200 and B300 servers list 10 to 35 °C, so a room that runs the H100 system within its range suits them. Depth and height change with the maker: the ASUS ESC NB8-E11 is 885 mm deep and 10U high, while Supermicro keeps 8U at 950 mm. The eight-card H200 NVL server goes the other way and frees about 3.9 kW of the position by our estimate. Our article on HGX B200 server power and cooling covers the room in detail.

Software: compute capability, CUDA and drivers

The H100 is compute capability 9.0, the B200 10.0 and the B300 10.3 in NVIDIA's CUDA list. NVIDIA's release notes for CUDA 12.8 add compiler support for SM_100, with a Linux driver of 570.26 or later, and those for CUDA 12.9 add sm_103 for the B300, with a driver of 575.51.03 or later. NVIDIA's R570 driver notes (570.86.15) list the HGX B200 8-GPU board.

Under NVIDIA's compatibility rules, a cubin runs only on GPUs of the same major compute capability, so kernels compiled for 9.0 do not run on a B200, and architecture-specific PTX such as compute_90a does not run on Blackwell either. Every container image, PyTorch build and custom extension from the H100 years has to carry code for 10.0 or PTX that the driver can compile; our article on the "no kernel image" error on Blackwell shows how to find the binary at fault with cuobjdump. Since vLLM 0.33.0 (2 November 2026) its release wheels and images are built for CUDA 13.0 only, which needs an R580 driver or newer. NVIDIA's driver lifecycle table (updated 4 November 2026) lists R580 as a long-term support branch to June 2028 and R620 to September 2029; our guide to driver branches and CUDA versions explains how branches and toolkits pair. The eight-card H200 NVL server stays at 9.0, so Hopper builds run there unchanged.

MIG profiles change name and size. NVIDIA's MIG user guide (updated 4 November 2026) lists 1g.10gb up to seven times on the H100 80 GB, 1g.23gb on the B200, 1g.34gb on the B300 and 1g.18gb on the H200, all with up to seven instances, and driver minimums of R525 525.85.12, R570 570.133.20, R580 580.82.07 and R550 550.90.07. Scheduler resource names and GPU Operator layouts that refer to 1g.10gb have to be rewritten; the B200 and B300 profiles are listed in our article on B200 and B300 MIG profiles.

A DGX H100 runs DGX OS; an HGX server runs the operating system you choose, such as Ubuntu or RHEL, with NVIDIA's drivers and CUDA; for cluster management there is Base Command Manager, included with NVIDIA AI Enterprise.

What to keep from the H100 installation

The cluster network can stay with an HGX B200 server. The DGX H100 has eight ConnectX-7 adapters at 400 Gb/s, and Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives its SYS-822GS-NBRT eight single-port ConnectX-7 or BlueField-3 cards at up to 400 Gb/s, one per GPU, so the port speed per GPU is the same; confirm cables and optics against the maker's list. An HGX B300 server brings ConnectX-8 at up to 800 Gb/s per GPU on the board, and switches, optics and cables are then planned for 800 Gb/s; our article on the ConnectX-8 SuperNIC in an AI server covers the adapter.

Storage, the scheduler and the model repository stay, and FP8 checkpoints run on every successor; INT8 models should move to FP8 on the B300, which NVIDIA's HGX table lists at 3 POPS of INT8 against 72 POPS sparse on the B200. The power distribution needs a fresh look even where the feed is large enough: six 3.3 kW supplies on the DGX H100 become six 6,600 W supplies on Supermicro's B200 server or twelve 3,000 W supplies on Gigabyte's 8U B200 models, so the maker confirms the outlet count and connector before the PDUs are reused.

Which successor for which H100 job mix

FP8 serving and fine-tuning of 70B to 700 GB models. The HGX B200. It keeps the eight-GPU NVLink fabric, the 400G cluster network and FP64, and adds memory, bandwidth and FP4. HGX B200 servers also have a considerably shorter lead time than B300.

Models above about 1.2 TB, NVFP4 at scale. The HGX B300, if the code needs no FP64 and the network can move to 800 Gb/s. Our comparison of HGX B200 now or HGX B300 later weighs the two.

FP64 simulation on the H100. The HGX B200 at 296 TFLOPS, or eight H200 NVL at 240 TFLOPS and 480 on FP64 Tensor Cores; not the B300. Our FP64 GPU server comparison covers the codes.

Inference of models up to about 490 GiB per copy in less power. The eight-card H200 NVL server, which runs Hopper builds unchanged at about 6.3 kW. It has no NVLink path across all eight GPUs for tensor parallelism, as our comparison of HGX B200 and eight H200 NVL shows.

Many copies of models up to 70B, plus virtual desktops. A PCIe server with RTX PRO 6000 Server Edition cards, as compared in eight RTX PRO 6000 Server Edition cards or an HGX B200 server and RTX PRO 6000 Server Edition vs H100. The same decision one generation back is in replacing an 8-GPU A100 SXM server.

Ordering the successor from us

We supply HGX B200 and HGX B300 servers per project from Supermicro, ASUS, Gigabyte, HPE and Lenovo: the same GPUs on the same NVIDIA HGX board as the DGX systems, with warranty and service from the server maker, handled through us. If you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. The eight-card H200 NVL server we build to order, assembled and tested before delivery. We sell only new equipment.

On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO. Your data-centre staff or colocation provider rack the server, and hardware service on site comes from the server maker as configured in the quote. Delivery within the EU; other destinations on request, subject to export and sanctions rules. To plan the budget for the change, you can request our current NVIDIA price list. Write to us with the job mix from your H100 scheduler, the share of FP64 work and the feed of the rack position, and we propose the successor and the configuration.

FAQ

What is the successor to the H100 SXM?
On NVIDIA's HGX page, read 27 November 2026, the eight-GPU boards after Hopper are HGX B200 and HGX B300, with HGX Rubin NVL8 at the top of the page; the H100 no longer appears there. HGX Rubin NVL8 servers we will quote per project once Supermicro, ASUS or Gigabyte take orders. For an 8-GPU H100 SXM server the like-for-like successor is an HGX B200 server, with eight GPUs on NVLink, 1.4 TB and FP64 at 296 TFLOPS.
Is an HGX B200 server a drop-in replacement for an H100 server?
In the rack, often: Supermicro's B200 server keeps 8U, and a 400 V 32 A three-phase position and the 400G cluster network can stay. In power it draws more, 14.3 kW for NVIDIA's DGX B200 against 10.2 kW for the DGX H100, and in software it needs builds for compute capability 10.0, CUDA 12.8 or later and an R570 driver or newer.
How much faster is an HGX B200 than eight H100 SXM?
On NVIDIA's figures, 36 PFLOPS of dense FP8 against about 15.8, 2.3 times by our arithmetic, plus 72 PFLOPS of dense FP4, which the H100 does not compute. Memory bandwidth per GPU rises from 3.35 to up to 8 TB/s and memory from 640 GB to 1.4 TB.
Can a DGX H100 replacement use the same power feed?
Usually, if the position has a 400 V 32 A three-phase feed on each side, which carries 17.74 kW at our 80 per cent margin: enough for the DGX B200's 14.3 kW and the 15 kW Supermicro gives as the node maximum for HGX B300. An eight-card H200 NVL server needs about 6.3 kW by our estimate.
Do H100 containers run on a B200?
Only if they carry code for compute capability 10.0 or PTX the driver can compile. Cubins built for 9.0 do not run on the B200, and architecture-specific compute_90a PTX does not run on Blackwell. On eight H200 NVL, compute capability 9.0, they run unchanged.
DGX H100 replacement: DGX B200 or an HGX B200 server?
The GPUs are the same eight B200 on the same NVIDIA board. We do not supply DGX systems; we supply HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project, with warranty and service from the server maker.
Do you supply H100 servers?
No. We sell only new equipment and do not supply the H100. We supply HGX B200 and HGX B300 servers per project and build eight-card H200 NVL servers to order.

Send us the GPU counts per job from your H100 scheduler, the share of FP64 work and the feed of the rack position. We answer with the successor that fits, HGX B200, HGX B300 or eight H200 NVL. We reply within one business day.

Request a price
Talk to an expert

We reply within one business day

We use your details only to answer your enquiry; see our privacy policy.

request@eurokommerz.at