DGX B300 alternatives: HGX B300 and B200 servers from Supermicro, ASUS and Gigabyte
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- Supermicro, ASUS and Gigabyte build servers on NVIDIA's eight-GPU HGX B300 and HGX B200 boards; the GPUs and NVLink are the same in every model, the chassis, processors, power supplies and cooling are the maker's
- One character separates Supermicro's two 8U air-cooled models: the SYS-822GS-NBRT carries HGX B200 with 180 GB per GPU, the SYS-822GS-NB3RT carries HGX B300
- The power layouts differ widely: six 6,600 W supplies as 3+3 at Supermicro, ten 3,200 W as 5+5 on the ASUS XA NB3I-E12 and twelve 3,000 W at Gigabyte
- No maker publishes a system power figure for these servers on the model pages read on 27 November 2026; Supermicro's SRS-48UAC-B300SX rack page prints "15kW (full load power draw)" per SYS-822GS-NB3RT node; heights run from 4U (liquid-cooled) to 10U (air-cooled)
- We supply HGX B300 and HGX B200 servers of these three makers per project, with warranty and service from the server maker handled through us
Supplied by Eurokommerz: HGX B300 servers Request a price →
Who builds HGX B300 and HGX B200 servers
The alternatives to a DGX B300 are HGX B300 servers from the server makers, with the same eight Blackwell Ultra GPUs on NVIDIA's board. This comparison covers Supermicro (SYS-822GS-NB3RT, 8U air-cooled), ASUS (XA NB3I-E12, 9U) and Gigabyte (G894-SD3-AAX7 and G894-AD3-AAX7, 8U), with liquid-cooled 4U and 2 OU versions at Supermicro. For HGX B200 the same makers list the SYS-822GS-NBRT, the ESC NB8-E11 and the G893 and G894 models with the AAX5 suffix. All of them carry eight GPUs on NVIDIA's board; they differ in height, processors, power supplies, cooling and weight.
The figures below come from the makers' product pages, datasheets and technical guides as read on 27 November 2026. What the DGX B300 adds in software and support is the subject of our comparison of DGX B300, HGX B300 and DGX B200.
We supply HGX B300 and HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project, as set out on our page DGX B300 or HGX B300 server: what we supply. Send us your rack, its power feeds and a preferred maker, if you have one, and we answer with the models that fit.
For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it. Our guide to the end-user certificate for NVIDIA GPUs explains the declaration behind it.
Supermicro model names: NBRT for B200, NB3RT for B300
Supermicro's names differ by one character. The SYS-822GS-NBRT is described as "DP Intel 8U System with NVIDIA HGX B200 8-GPU", with 180 GB per GPU. The SYS-822GS-NB3RT, with a "3" after "NB", is the 8U system on HGX B300. The same pattern runs through Supermicro's December 2025 brochure "NVIDIA Blackwell Solutions": SYS-422GS-NBRT-LCC is a 4U liquid-cooled B200 server, SYS-422GS-NB3RT-LCC the 4U liquid-cooled B300 version. Write the full model name in an enquiry, because a request for an "822GS" does not say which board is meant.
The two 8U models are not identical apart from the board. The B200 version weighs 133 kg net against 119 kg for the B300 version. Its product page prints 5200 MT/s for two DIMMs per channel, where the B300 page prints 6000 MT/s. It also has no ConnectX network ports on the product page, a difference covered under network below. The B300 model is described in detail in our article on the Supermicro SYS-822GS-NB3RT.
HGX B300 server models by maker
| MODEL | HEIGHT | PROCESSORS | POWER SUPPLIES | COOLING |
|---|---|---|---|---|
| Supermicro SYS-822GS-NB3RT | 8U | 2 × Xeon 6700P, up to 350 W | 6 × 6,600 W, 3+3 | air |
| Supermicro AS-8126GS-NB3RT | 8U | 2 × AMD EPYC 9005/9004 | 6 × 6,600 W, 3+3 | air |
| Supermicro 4U NB3RT models | 4U | Intel (SYS) or AMD (AS) | 4 × 6,600 W, 2+2 | liquid |
| Supermicro SYS-222GS-NB3OT-ALC | 2 OU, OCP | 2 × Xeon 6700P | rack power shelves | liquid |
| ASUS XA NB3I-E12 | 9U | 2 × Xeon 6, up to 350 W | 10 × 3,200 W, 5+5 | air |
| Gigabyte G894-SD3-AAX7 | 8U | 2 × Xeon 6700/6500, up to 350 W | 12 × 3,000 W, redundant | air |
| Gigabyte G894-AD3-AAX7 | 8U | 2 × Xeon 6900, up to 500 W | 12 × 3,000 W, 6+6 | air |
Supermicro brochure "NVIDIA Blackwell Solutions" (December 2025) and product pages; ASUS datasheet XA NB3I-E12 (V1); Gigabyte product pages; read 27 November 2026. Processors of the Supermicro AMD, 4U and 2 OU models from our SYS-822GS-NB3RT article.
Supermicro's three 4U models are the SYS-422GS-NB3RT-LCC, the SYS-422GS-NB3RT-ALC and the AS-4126GS-NB3RT-LCC.
Supermicro and NVIDIA print GPU memory differently. Supermicro gives 288 GB per GPU and 2.3 TB per system, NVIDIA's HGX page 2.1 TB for the eight GPUs. The GPUs are the same; we plan with NVIDIA's 2.1 TB.
HGX B200 server models by maker
| MODEL | HEIGHT | PROCESSORS | POWER SUPPLIES | COOLING |
|---|---|---|---|---|
| Supermicro SYS-822GS-NBRT | 8U | 2 × Xeon 6700/6500, up to 350 W | 6 × 6,600 W, 3+3 | air |
| Supermicro AS-A126GS-TNBR | 10U | 2 × EPYC 9005/9004, up to 500 W | 6 × 5,250 W, 3+3 | air |
| Supermicro SYS-422GS-NBRT-LCC | 4U | 2 × Xeon 6700P, up to 350 W | 4 × 6,600 W, 2+2 | liquid |
| ASUS ESC NB8-E11 | 10U | 2 × 4th/5th Gen Xeon, 350 W | 6 × 3,000 W, 5+1 | air |
| Gigabyte G893-SD1-AAX5 | 8U | 2 × 5th/4th Gen Xeon, 350 W | 12 × 3,000 W, 6+6 | air |
| Gigabyte G894-SD1-AAX5 | 8U | 2 × Xeon 6700/6500, up to 350 W | 12 × 3,000 W, 6+6 | air |
| Gigabyte G894-AD1-AAX5 | 8U | 2 × Xeon 6900, up to 500 W | 12 × 3,000 W, 6+6 | air |
| Gigabyte G4L3-SD1-LAX5 | 4U | 2 × 5th/4th Gen Xeon | 8 × 3,000 W, 4+4 | liquid |
Supermicro product pages and brochure (December 2025); ASUS datasheet ESC NB8-E11 (29 May 2025); Gigabyte product pages; read 27 November 2026.
NVIDIA prints 1.4 TB for the eight B200 GPUs of the board, 8 × 180 GB. Supermicro lists two more 10U B200 servers in its brochure, the SYS-A22GA-NBRT with Xeon 6900 and the SYS-A21GE-NBRT with 5th or 4th Gen Xeon, and three more 4U liquid-cooled ones. ASUS names only the ESC NB8-E11 as its HGX B200 system in its glossary; we found no ASUS B200 model with Xeon 6 or EPYC. Gigabyte announced an AMD twin of the G4L3, the G4L3-ZD1-LAX5, in a press release of 3 July 2025; we have not read its specifications.
Processors and memory: where the makers part
The processor platform is the clearest difference. Supermicro's SYS-822GS-NBRT, Gigabyte's G894-SD1-AAX5 and ASUS's XA NB3I-E12 use Intel Xeon 6; Supermicro and Gigabyte name the LGA-4710 socket. The ASUS ESC NB8-E11 and Gigabyte's G893-SD1-AAX5 stay on 4th or 5th Gen Xeon Scalable, an older platform. The ESC NB8-E11 datasheet prints both DDR5-5600 and DDR5-4400, so have the speed stated in the quote.
Gigabyte's AD models take Xeon 6900 processors of up to 500 W with 24 DIMM slots instead of 32. Gigabyte also lists MRDIMM at 8000 MT/s for the G894-SD1-AAX5. For AMD, Supermicro's AS-A126GS-TNBR takes two EPYC 9005 or 9004 processors and up to 6 TB of DDR5 in 24 slots, at 6400 MT/s with EPYC 9005.
Network ports: on the board for B300, in slots for B200
On HGX B300, NVIDIA's reference architecture places eight ConnectX-8 SuperNICs on the baseboard, one per GPU, at up to 800 Gb/s. The makers show them as eight OSFP ports: Supermicro, and Gigabyte for 800G XDR InfiniBand or dual 400GbE. ASUS lists eight embedded ConnectX-8 SuperNICs.
HGX B200 servers take their cluster network as add-in cards. Supermicro's brochure gives the SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s)" in a "1:1 GPU-to-NIC ratio", as add-in cards for the eight low-profile PCIe slots; the product page lists only the slots. ASUS routes eight PCIe Gen5 x16 slots through a switch for one NIC per GPU. Gigabyte names ConnectX-7 and BlueField-3 as compatible. Have the quote list the eight NICs as lines, because the product pages do not show them as standard. What the 800G adapter changes is covered in the ConnectX-8 SuperNIC in an AI server.
Power supplies, feeds and the missing system figure
The model pages read print no system power figure for any of these servers. Supermicro's SRS-48UAC-B300SX rack page prints one for the B300 model: "15kW (full load power draw)" for each SYS-822GS-NB3RT node in that rack configuration. The per-GPU figures are published: NVIDIA's HGX B200 carbon footprint summary gives the B200 "up to 1000 W", and Supermicro gives 1,100 W per B300. Eight B300 at 1,100 W are 8.8 kW for the GPUs alone, by our arithmetic. NVIDIA's own systems serve as reference: 14.3 kW maximum for the DGX B200 in its user guide, and 14.5 kW with a 15 kW system maximum for the DGX B300 in its user guide of 10 November 2026.
The supplies say more about the feeds than about consumption. Supermicro's 6,600 W unit gives 6,500 W at 230 to 238.9 V and 5,900 W at 200 to 207.9 V. Gigabyte's 3,000 W unit gives 2,900 W at 200 to 220 V and 3,002.4 W at 220 to 240 V, and Gigabyte notes that the C19 cords are not included. ASUS does not state an input voltage for the XA NB3I-E12. The non-redundant half of each layout gives, by our estimate, 19.5 kW at Supermicro (three × 6,500 W at 230 V), 18.0 kW at Gigabyte (six × 3,002.4 W) and 16.0 kW at ASUS (five × 3,200 W). These figures describe supply capacity and say nothing about consumption.
The count of supplies sets the count of PDU outlets: six on a Supermicro 8U, ten on the ASUS, twelve on Gigabyte. On two feeds, 3+3, 5+5 and 6+6 keep the server running when one feed fails; the 5+1 of the ASUS ESC NB8-E11 does not by our reading. PSU redundancy in GPU servers explains the layouts.
Depth, weight and the rack
| MODEL | HEIGHT | DEPTH | WEIGHT | WEIGHT BASIS |
|---|---|---|---|---|
| Supermicro SYS-822GS-NB3RT | 8U | 950 mm | 119 kg | net |
| Supermicro SYS-822GS-NBRT | 8U | 950 mm | 133 kg | net |
| Supermicro SYS-422GS-NBRT-LCC | 4U | 991.4 mm | 85 kg | net |
| ASUS XA NB3I-E12 | 9U | 945 mm | 120 kg | net |
| ASUS ESC NB8-E11 | 10U | 885 mm | 121 kg | net, no CPU, DRAM, drives |
| Gigabyte G894-SD1-AAX5 | 8U | 923 mm | 91.6 kg | net |
| Gigabyte G894-SD3-AAX7 | 8U | 923 mm | not listed |
makers' product pages, datasheets and technical guides as in the tables above, read 27 November 2026.
The weights stand on different bases, so they are not a ranking. ASUS weighs the ESC NB8-E11 without processors, memory and drives, and Gigabyte prints 91.6 kg for both the G894-SD1-AAX5 and the G894-AD3-AAX7. Ask for the weight of the configured system before the floor and the lift are planned.
Depth decides whether an existing rack fits: the models in the table run from 885 mm (ASUS ESC NB8-E11) to 991.4 mm (Supermicro SYS-422GS-NBRT-LCC). Gigabyte gives an operating range of 10 to 30 °C, where Supermicro and ASUS give 10 to 35 °C. Our site survey for GPU servers lists what to measure.
Liquid cooling and what comes with it
The liquid-cooled models come with conditions. Supermicro describes its 4U B200 model as requiring a "complete rack and onsite service", and states that complete liquid-cooled rack integration is required for purchase. Gigabyte's G4L3-SD1-LAX5 has cold plates on CPUs, GPUs and NVSwitch, leak detection and a coolant inlet of at most 45 °C. Plan these with the facility team before a model is chosen; liquid cooling for GPU racks covers the room side.
Warranty and on-site service come from the server maker, in the terms configured in the quote, and we handle them for you. What the makers ask of a site for such visits is in on-site service for GPU servers. Your data-centre staff or the colocation provider rack the server. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO.
Choosing between the makers
| SITUATION | MODELS TO LOOK AT |
|---|---|
| Air-cooled 19-inch rack | Supermicro 8U, Gigabyte G894, ASUS XA NB3I-E12 |
| AMD processors | Supermicro AS models |
| Liquid-cooled facility | Supermicro 4U -LCC/-ALC, Gigabyte G4L3 |
| Existing fleet of one maker | that maker's model, for one set of tools and support |
our reading of the tables above; not a ranking by the makers.
Which board comes first is a separate question. HGX B300 has 288 GB per GPU and the on-board 800G network; HGX B200 has 180 GB per GPU and a considerably shorter lead time than B300. Our comparison HGX B200 now or HGX B300 later works through that decision, and buying an HGX B200 server covers the order. Where no B200 or B300 server is needed at all, buying a single B200 or B300 GPU shows the smaller options. Eight-card PCIe servers of the same makers are compared in Supermicro vs Gigabyte vs ASUS 8-GPU servers.
We do not publish prices, but companies can request our current NVIDIA price list. For a quote, tell us the end user, the site and the use, and we work out the configuration with the maker of your choice.
FAQ
Which companies make HGX B300 servers?
What is the difference between Supermicro SYS-822GS-NBRT and SYS-822GS-NB3RT?
Which HGX B200 server models are there?
Is an OEM HGX B300 server an alternative to the DGX B300?
How much power does an HGX B300 server need?
Does ASUS make an HGX B300 server?
Send us the end user's company, the installation site and the intended use, with the rack, the feeds and a preferred maker. We answer with the HGX B300 or HGX B200 models that fit and the next steps. We reply within one business day.
Request a priceWe reply within one business day