BLOG · GUIDE ·

Connecting two HGX servers: the network for a 16-GPU cluster on HGX B200 or B300

Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software

IN BRIEF
  • Two HGX servers become one 16-GPU cluster through a separate east-west compute network: NVIDIA's reference architecture gives each HGX B200 server eight 400 GbE SuperNICs, one per GPU, and each HGX B300 server eight ConnectX-8 SuperNICs on the board, configured as 2 × 400 Gb Ethernet each
  • NVIDIA's Enterprise Reference Architecture for HGX covers Spectrum-X Ethernet only and builds on a scalable unit of four servers (32 GPUs); it tabulates no two-server design, so every two-server figure on this page is our arithmetic
  • By our arithmetic two HGX B200 servers need 16 compute links of 400 Gb/s, four converged links of 200 Gb/s and 24 out-of-band ports of 1 Gb/s; two HGX B300 servers need 32 compute links of 400 Gb/s
  • Inside a server the GPUs talk over NVLink at 1.8 TB/s per GPU; across servers one 400 Gb/s port carries about 50 GB/s each way, so tensor parallelism stays inside the server and pipeline or data parallelism crosses the network
  • We supply HGX B200 and HGX B300 servers per project from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo with their network adapters; the switches are not part of our offer

Supplied by Eurokommerz: HGX B200 servers  Request a price →

Two HGX servers as one 16-GPU cluster

Two HGX B200 servers are joined into a 16-GPU cluster by a dedicated compute network between their GPUs: one 400 Gb/s adapter per GPU, eight per server, sixteen links into RDMA switches running Spectrum-X Ethernet or InfiniBand. NVIDIA's Enterprise Reference Architecture for HGX B200, last updated 31 August 2026, describes this fabric with Spectrum-X Ethernet and a building block of four servers; it shows no design for two, so the two-server counts below are our arithmetic, labelled as such. HGX B300 servers bring eight 800 Gb/s ConnectX-8 SuperNICs on the board instead of separate cards.

Inside one server nothing of this is needed: NVIDIA's HGX page lists NVLink at 1.8 TB/s per GPU across all eight GPUs through NVLink 5 switches. A second server starts to need the fabric when one job, a training run or a model too large for one server, spans both.

We supply HGX B200 servers and HGX B300 servers per project from Supermicro, ASUS, Gigabyte, HPE and Lenovo, with the network adapters configured for the cluster you plan. For an order we need the end user's company, the installation site and the intended use; the server maker and NVIDIA review the project before they confirm it, as our guide to the end-user certificate for NVIDIA GPUs describes. Send us the number of servers and the fabric you have in mind, and we reply with the adapters, ports and cables each server needs.

What each HGX server brings to the fabric

NETWORKHGX B200 NODEHGX B300 NODE
Compute, east-west8 × BlueField-3 B3140H, 400 GbE8 × ConnectX-8, 800 GbE, as 2 × 400G
Converged, north-south1 × BlueField-3 B3220, 2 × 200 GbE1 × BlueField-3 B3240, 2 × 400 GbE
Out-of-band management12 × 1 Gb/s6 × 1 Gb/s
Compute and converged switchSN5600 / SN5610, 128 × 400 GbESN5600, 128 × 400 GbE
Out-of-band switchSN2201, 48 × 1 Gb + 4 × 100 GbESN2201, 48 × 1 Gb + 4 × 100 GbE

NVIDIA Enterprise Reference Architecture, HGX AI factory, network logical architecture, for HGX B200 (last updated 31 August 2026) and HGX B300 (last updated 18 May 2026), read 27 November 2026.

The B300 document words the compute adapters as "Eight NVIDIA ConnectX-8 single-port 800 GbE SuperNICs, configured for 2x400Gb Ethernet breakout". The B200 document lists 128-port switches in its table and speaks of "64-port switches" in its section on rails; 64 ports at 800G are 128 at 400G, which is our reading of the difference.

The server makers implement this in two ways. For HGX B200 the adapters are cards: Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives its SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s)" and two dual-port BlueField-3 DPUs at a "1:1 GPU-to-NIC ratio", while its product page lists only the eight low-profile slots. ASUS routes eight Gen5 x16 slots of the ESC NB8-E11 through PCIe switches for up to one NIC per GPU, and Gigabyte lists its G893-SD1-AAX5 and G894-SD1-AAX5 as compatible with ConnectX-7 and BlueField-3. For HGX B300 the SuperNICs sit on the board: eight OSFP ports at 800 GbE on Supermicro's SYS-822GS-NB3RT, eight embedded ConnectX-8 on the ASUS XA NB3I-E12, and on Gigabyte's G894-SD3-AAX7 eight rear OSFP ports for "800 Gb/s XDR InfiniBand or dual 400 Gb/s Ethernet". Whether the eight cards of a B200 server are in the first order is a line of the configuration, as our HGX B200 specs explain; the ConnectX-8 SuperNIC and the BlueField-3 DPU have their own articles.

Four networks in NVIDIA's reference architecture

The reference architecture separates the traffic of an HGX cluster into networks with their own adapters and switches:

  • The compute network, east-west, is "an RDMA based fabric in a leaf-spine architecture", rail-optimised through the SuperNICs. A rail joins the GPUs of the same position in every server; the B200 document pairs rails per leaf as "(1+5, 2+6, 3+7, 4+8)" in a non-blocking fat tree.
  • The converged network, north-south, connects each node with "two 200 GbE ports to two separate switches to provide redundancy and high storage throughput" on HGX B200, and with two 400 GbE ports on HGX B300, where it carries "compute, storage, in-band management, and end-user connections".
  • Storage attaches to the converged network, and a customer north-south network connects the users.
  • The out-of-band management network gives "1Gb RJ45 connectivity for all nodes".

The separation matters even with two servers. A training job that shares its adapters with storage reads and user traffic competes for the same links, and the out-of-band network is the way into a server whose operating system no longer answers.

NVIDIA's building block is four servers

NVIDIA's HGX documents build the cluster from a scalable unit of four nodes, 32 GPUs. For HGX B200 one scalable unit has 32 compute links of 400 Gb/s, 12.8 Tb/s, and eight converged links of 200 Gb/s, 1.6 Tb/s. The smallest design tabulated with switch and cable counts is 32 nodes, 256 GPUs. Below that the documents only note that for lower node counts the converged network can be consolidated with the compute network, and that transceivers and cables are then additional; the B300 document gives 16 nodes for that case. A design for two nodes is not in either document, and InfiniBand is not covered.

For InfiniBand at small scale, NVIDIA's DGX BasePOD reference architecture (last updated 14 April 2026) is the nearest NVIDIA document. It names "Compute nodes (2-8)" for DGX B200, H200 and H100 and tabulates four and eight nodes: two NVIDIA Quantum QM9700 NDR400 InfiniBand switches for the compute fabric in both cases, "eight compute connections ... running at NDR400" per node, two SN4600C for the management and storage fabric, and one SN2201 for out-of-band management with four nodes, two with eight. The BasePOD is written for DGX systems; we read it as the closest NVIDIA reference for HGX servers with the same eight adapters per node, not as a statement for them.

For the scale above, the DGX SuperPOD B200 reference architecture (2 September 2026) uses 32 nodes per scalable unit, with one system removed "to accommodate for UFM connectivity", and Supermicro's SuperCluster datasheet for 4U liquid-cooled B200 systems (February 2025) offers the compute fabric as Quantum-2 400G InfiniBand or Spectrum-4 400GbE.

Two servers, and four, by our arithmetic

ITEM2 × HGX B2002 × HGX B3004 × HGX B200, ONE SU
GPUs161632
Compute links16 × 400 Gb/s32 × 400 Gb/s32 × 400 Gb/s
Compute bandwidth6.4 Tb/s12.8 Tb/s12.8 Tb/s
Converged links4 × 200 Gb/s4 × 400 Gb/s8 × 200 Gb/s
Out-of-band ports, 1 Gb/s241248
Share of one 128-port switch16 ports, 1/832 ports, 1/432 ports, 1/4

our arithmetic from the per-node counts of NVIDIA's Enterprise Reference Architecture for HGX B200 and HGX B300 (read 27 November 2026); the column for four HGX B200 servers is NVIDIA's own scalable unit for the compute and converged links, the out-of-band count is our multiplication.

Two HGX B200 servers fill only a fraction of one SN5600 by port count. That does not make one switch NVIDIA's design: the reference architecture spreads the rails over leaf switches and doubles the converged switches for redundancy, and a single compute switch fails as a whole. With two servers the choice is between one switch and a later rebuild, or the leaf layout of the four-node unit from the start, which a second pair of servers then fills. Our recommendation for a two-server start that is meant to grow is the second.

None of the NVIDIA documents we read describes connecting two HGX servers without a switch, so we do not plan with it. Every compute and converged link needs a cable and, depending on the port types and the distance, transceivers at both ends; NVIDIA counts them separately, and the exact list follows from the network design.

InfiniBand or Spectrum-X Ethernet for two HGX servers

Both fabrics carry RDMA between the GPUs, and NCCL reaches the adapters through IB verbs in both cases. NVIDIA's enterprise HGX documents use Spectrum-X Ethernet; the BasePOD uses NDR400 InfiniBand; the SuperPOD runs its storage over InfiniBand or Ethernet. Supermicro's SuperCluster offers either. The adapters do not decide it: BlueField-3 SuperNICs run 400GbE by default or NDR InfiniBand, and the ConnectX-8 runs one 800 Gb/s XDR InfiniBand port or two 400GbE links on one OSFP cage, as our ConnectX-8 article sets out from NVIDIA's manual.

What differs is the operation. InfiniBand needs a subnet manager, and RoCE on Ethernet needs the same flow-control mode, lossless with priority flow control and ECN or lossy with ECN, on every switch the traffic crosses. Our guide to a GPU cluster without InfiniBand covers both, with the NCCL log line that shows whether RDMA is in use. For HGX B300 at 800 Gb/s InfiniBand, guidance for NVIDIA's Quantum-X800 switches was not in the enterprise documents we read.

What crosses the network in training and inference

The gap between the two links decides the layout of a job. NVIDIA lists 1.8 TB/s of NVLink per GPU; read like the H200 NVL bridge figure, a total for both directions, that is about 900 GB/s each way, which is our reading. One 400 Gb/s port carries 50 GB/s each way, an eighteenth of that. On HGX B300 each GPU has 800 Gb/s, 100 GB/s each way. NVIDIA's HGX page gives "networking bandwidth" of 0.8 TB/s for HGX B200 and 1.6 TB/s for HGX B300 without explaining the count; eight adapters of 400 or 800 Gb/s counted in both directions fit those figures, by our reading.

For inference, vLLM's documentation, as our cluster guide quotes it, sets tensor parallelism to the GPUs per node and pipeline parallelism to the number of nodes, and notes that "Efficient tensor parallelism requires fast internode communication". Pipeline parallelism sends only the activations at the stage boundary: for DeepSeek-V3.2 about 57 MB for a 2,000-token prompt, about 1.1 ms at 400 Gb/s by our arithmetic. Most models fit one server, though: an HGX B200 holds about 1,183 GiB for weights and cache by our rule, as which LLMs run on eight B200 shows, and two servers then run as replicas without east-west traffic, as PCIe servers such as Supermicro's servers for the RTX PRO 6000 Server Edition usually do.

For training, the method sets the traffic, as our page on fine-tuning on HGX B200 works out. A data-parallel LoRA on a 70B model all-reduces about 0.83 GB per GPU and step, about 17 ms at 50 GB/s by our arithmetic. A fully sharded full fine-tune moves several hundred GB per GPU and step, which runs at NVLink speed inside a server and would be throttled by a factor of about eighteen across the network. By our reasoning the sharding traffic belongs inside each server's NVLink domain, with only the exchange between server replicas crossing the fabric. Such two-server runs start where the model states exceed one server's 1,440 GB.

Storage, management and the software inside each node

Datasets and checkpoints for both servers belong on shared storage on the converged network, not on the compute fabric. The out-of-band network reaches each management controller; Supermicro's HGX B200 server has a 1 GbE BMC port next to two 10GbE ports on board. Base Command Manager, included with NVIDIA AI Enterprise, manages clusters of such servers.

Each server also runs its own NVLink fabric software. NVIDIA's Fabric Manager guide states that on NVSwitch-based HGX systems "the FM service needs to be manually installed", that the fourth-generation NVSwitch of Blackwell "requires an additional NVLSM service to configure the NVLinks and NVSwitches", and that Blackwell needs OFED or MOFED with libibumad3 and infiniband-diags and a Linux kernel 5.17 or later. By the guide these packages belong on every Blackwell HGX server, with or without an InfiniBand fabric between the servers. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO.

What to send us for a two-server project

We supply the HGX servers with their network adapters and the maker's cabling options; the switches are not part of our offer and come from your network team or integrator. Your data-centre staff or colocation provider rack and cable the servers. For the configuration we need:

  1. The number of servers now and later, and HGX B200 or HGX B300; our guide to HGX B200 now or HGX B300 later compares them, and HGX B200 has a considerably shorter lead time than B300.
  2. The fabric: Spectrum-X Ethernet or InfiniBand, and the switch ports reserved for the servers.
  3. The storage and user networks the converged adapters connect to.
  4. The end user's company, the installation site and the intended use, for the project review by the server maker and NVIDIA.

The models of the three makers are set side by side in our comparison of HGX B200 and B300 servers from Supermicro, ASUS and Gigabyte; for budgeting, request our current NVIDIA price list. Describe the cluster you plan, and we reply with the server configuration and the adapter and port list for your network design.

FAQ

How do you connect two HGX B200 servers?
Through a separate RDMA compute network: one 400 Gb/s adapter per GPU, eight per server, into Spectrum-X Ethernet or InfiniBand switches, plus a converged network for storage and users and a 1 Gb/s out-of-band network. By our arithmetic from NVIDIA's reference architecture that is 16 compute links, four converged links and 24 management ports for two servers.
Does NVIDIA have a reference design for a 16-GPU cluster?
Not in the enterprise reference architecture for HGX, which starts from a scalable unit of four servers (32 GPUs) and tabulates switch and cable counts from 32 servers. NVIDIA's DGX BasePOD names 2 to 8 DGX nodes with InfiniBand but tabulates only four and eight.
InfiniBand or Ethernet for an HGX B200 cluster?
Both carry RDMA. NVIDIA's enterprise HGX documents use Spectrum-X Ethernet with SN5600 switches; the DGX BasePOD uses Quantum QM9700 NDR400 InfiniBand. The BlueField-3 and ConnectX-8 adapters run either; the choice follows from the switches and the operating skills you have.
How many NICs does an HGX B200 server need for a cluster?
Eight compute adapters at 400 Gb/s, one per GPU, plus one dual-port adapter for the converged network, in NVIDIA's reference architecture. HGX B300 servers carry their eight ConnectX-8 SuperNICs on the board.
Can tensor parallelism span two HGX servers?
It can, but vLLM's documentation notes that efficient tensor parallelism requires fast internode communication, and one 400 Gb/s port carries about 50 GB/s each way against about 900 GB/s of NVLink per GPU at our reading. The usual layout keeps tensor parallelism inside each server and uses pipeline or data parallelism across them.
Can two HGX servers be connected without a switch?
None of the NVIDIA documents we read describes a switchless link between two HGX servers, so we do not plan with one. The reference designs connect every compute adapter to a leaf switch.
Do you supply the network switches?
No. We supply HGX B200 and HGX B300 servers per project from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo with their network adapters; the switches come from your network team or integrator, and we provide the adapter and port list for their design.

We supply HGX B200 and HGX B300 servers per project with the adapters for your cluster. Send us the number of servers, the fabric, the storage network and the end user. We reply within one business day.

Request a price
Talk to an expert

We reply within one business day

We use your details only to answer your enquiry; see our privacy policy.

request@eurokommerz.at
Jordangasse 7, 1010 Vienna