BLOG · COMPARISON · · UPDATED

DGX Station GB300 or an HGX B200 server: one GPU at the desk or eight in the rack

Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software

IN BRIEF
  • The DGX Station GB300 has one Blackwell Ultra GPU with 252 GB of HBM3e and 496 GB of LPDDR5X on its Grace CPU, at 1,600 W of total system power by NVIDIA
  • An HGX B200 server has eight B200 GPUs with 180 GB each, 1.4 TB of HBM3e as NVIDIA prints it, joined by NVLink at 1.8 TB/s per GPU
  • By our sizing rule the Station holds Llama 3.3 70B in FP8 for 112 concurrent 8K conversations, an HGX B200 server as eight copies for 512
  • The Station runs on an office circuit of 230 V by our estimate; an HGX B200 server is a rack system of about 133 kg (Supermicro) with six 6,600 W supplies, for a data centre
  • We supply the ASUS and Gigabyte versions of the DGX Station GB300 and HGX B200 servers from several makers per project

Supplied by Eurokommerz: HGX B200 servers  Request a price →

DGX Station GB300 or HGX B200 server: the difference in one paragraph

The NVIDIA DGX Station GB300 is a deskside system with one Blackwell Ultra GPU: 252 GB of HBM3e at 7.1 TB/s, plus 496 GB of LPDDR5X on its 72-core Grace CPU, at 1,600 W of total system power by NVIDIA. An HGX B200 server is a rack server with eight B200 GPUs of 180 GB each, 1.4 TB of HBM3e as NVIDIA prints it, joined by NVLink at 1.8 TB/s per GPU, and power supplies sized for a data centre. The Station suits one developer or a small team at a desk; the HGX B200 server suits a production service for many users and models that need more than 252 GB of GPU memory.

We supply both per project: the manufacturers' versions of the DGX Station GB300 from ASUS and Gigabyte, and HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo. Send us the models and the number of people who will use the system, and we answer with the memory arithmetic for both and a quote for the one that fits.

ASPECTDGX STATION GB300HGX B200 SERVER
GPUs1 × Blackwell Ultra8 × B200 on one board
GPU memory252 GB HBM3e, 7.1 TB/s8 × 180 GB, 1.4 TB HBM3e
Other memory496 GB LPDDR5X, 396 GB/s, coherentDDR5 per configuration
GPU linksNVLink-C2C to the CPU, 900 GB/sNVLink, 1.8 TB/s per GPU, 14.4 TB/s
FP4 Tensor20 PFLOPS sparse144 PFLOPS sparse, 72 dense
ProcessorsGrace, 72 Arm corestwo x86 processors
MIG instancesup to 7up to 7 per GPU, 56 in all
Power1,600 W total systemno system figure from the makers
Where it standsdesk or office floorrack in a data centre

NVIDIA's DGX Station product page and datasheet (August 2026), as cited in our DGX Station GB300 specs article (product page read 23 November 2026); NVIDIA's HGX page, the components page of NVIDIA's Enterprise Reference Architecture and NVIDIA's MIG user guide (updated 4 November 2026), read 27 November 2026.

The Station is built by several makers; NVIDIA's page lists seven. The two versions we supply are the ASUS ExpertCenter Pro ET900N G3 and the Gigabyte W775-V10-L01. HGX B200 servers carry the same NVIDIA board in each maker's chassis, such as Supermicro's SYS-822GS-NBRT; the specs and options are in our sibling article on HGX B200 server specs and configuration.

GPU memory: 252 GB on one GPU against 1.4 TB on eight

The Station's GPU memory is the 252 GB of HBM3e. The 496 GB of LPDDR5X is attached to the Grace CPU and reachable by the GPU over NVLink-C2C, coherently, at 396 GB/s, which is about an eighteenth of the HBM3e bandwidth. Weights and the cache of active conversations belong in the HBM3e, and the LPDDR5X serves as overflow, as our article on DGX Station GB300 specs and alternatives explains.

An HGX B200 server has 180 GB of HBM3e per GPU and up to 8 TB/s per GPU by NVIDIA's reference architecture. NVIDIA's HGX page prints 1.4 TB for the eight GPUs; eight times 180 GB is 1,440 GB. NVLink connects every GPU with every other at 1.8 TB/s, so one model can span all eight cards.

BY OUR RULEDGX STATION GB300HGX B200 SERVER
Usable per GPU208.2 GiB147.9 GiB
Usable in all208.2 GiB1,183.0 GiB
Llama 3.3 70B FP8, 8K112 conversations512 as eight copies
gpt-oss-120b, 32Kabout 131about 616 as eight copies
DeepSeek-V3.2 FP8, 690 GBnot in HBM3efits in GPU memory

our estimate by our users-per-card rule, 0.9 × the memory less 3 GiB per GPU, computed on the nominal 252 GB and 180 GB because NVIDIA publishes no driver-reported figure for either GPU in our files; Llama 3.3 70B FP8 67.7 GiB of weights and 1.25 GiB of FP8 cache per 8K conversation, gpt-oss-120b 60.8 GiB and 1.125 GiB per 32K conversation, DeepSeek-V3.2 from our eight-card H200 NVL guide; Station figures from our DGX Station team article.

For the HGX column we read 180 GB as 180 billion bytes: 167.6 GiB, times 0.9, less 3 GiB, gives 147.9 GiB per GPU. A Llama 3.3 70B copy leaves 80.2 GiB for the cache on one GPU, 64 conversations of 8K with an FP8 cache, and eight copies hold 512. The counts are what fits in memory at full context; they say nothing about speed. Which other models fit eight B200 is the subject of our sibling article on LLMs on eight B200, and the Station's own list is in which models run on the DGX Station GB300.

The two systems differ most for models above about 208 GiB. On the Station, a model of that size moves part of its weights into the LPDDR5X and generates more slowly. Kimi-K2.6, with 595 GB of INT4 weights, has more than twice the Station's HBM3e. On an HGX B200 server, DeepSeek-V3.2 in FP8 at about 690 GB sits entirely in GPU memory, with room for its cache.

Users and sharing: one GPU or eight

NVIDIA describes the Station as "an individual desktop for one user" or "a centralized compute node for multiple team members". Its blog of 21 October 2026 says the system can "serve 30+ users" without naming a model variant, an engine or a context length, and no public multi-user test of the Station exists in the documents we read. Our article on the DGX Station GB300 for a team sets out what is documented.

MIG divides each GPU into isolated instances. NVIDIA's MIG user guide lists up to seven 1g.31gb instances for the GB300 with 252 GB, and up to seven 1g.23gb instances for each B200 with 180 GB, so an HGX B200 server offers up to 56. The Station's seven instances are seven slices of one GPU; the server's 56 are slices of eight. A team that runs a model service and gives developers their own slices can do both on the server at once: four GPUs for the service, four split into 28 instances.

Copies decide how far a service scales. The Station holds one copy of a model on one GPU, and every user shares it. The HGX B200 server holds eight copies of a model that fits one GPU, or fewer copies of a larger one with tensor parallelism over NVLink, so the number of conversations grows with the GPU count. A failed GPU in the server stops one copy; a fault in the Station stops everyone.

Power, heat and the circuit

NVIDIA rates the Station at 1,600 W of total system power. On a 230 V circuit that is about 7 A by our estimate, and Gigabyte and ASUS print an input rating of 15 to 8 A over the voltage range. By the arithmetic of our article on DGX Station GB300 power and cooling in an office, one Station fits a 230 V circuit with a 16 A breaker planned at 80 per cent, and we recommend a circuit of its own.

The HGX B200 server is in another class. NVIDIA's carbon footprint summary for the HGX B200 gives each GPU a maximum of "Configurable up to 1000 W", so the eight GPUs alone come to 8 kW by our multiplication, before processors, memory, network cards and fans. The makers publish no system power figure for their HGX B200 servers on the pages we read. NVIDIA's own DGX B200, built on the same board class, is rated "14.3 kW max." in its user guide; if you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. Supermicro fits its SYS-822GS-NBRT with six 6,600 W Titanium supplies in a 3+3 layout, each delivering 6,500 W at 230 to 238.9 V; three of them give 19.5 kW of supply capacity by our arithmetic.

POWER AND HEATDGX STATION GB300HGX B200 SERVER
Rated power1,600 W total systemnot published by the makers
GPU powerwithin the 1,600 Wup to 1,000 W per GPU, 8 kW for eight
Power suppliesone 1,600 W supplySupermicro: 6 × 6,600 W, 3+3
Feed230 V office circuit, about 7 Adata-centre feeds per configuration
Heat into the roomup to about 1.6 kWall of the server's draw

NVIDIA's DGX Station product page and datasheet (August 2026) as cited in our office power article; NVIDIA's HGX B200 carbon footprint summary (July 2025); Supermicro's product page for the SYS-822GS-NBRT, read 27 November 2026; current at 230 V by our estimate.

Every watt ends up as heat in the room. For the Station that is up to about 1.6 kW in an office, which comfort cooling sized for people and laptops may not remove from one corner. For the server it is a rack load for a data centre with its own cooling; how to plan feeds, airflow and racks for it is the subject of our sibling article on HGX B200 server power and cooling in the data centre. We check rack, power and airflow before we quote; tell us the room or the rack position and its feeds, and we answer with the system that fits them.

Noise, size, weight and the room

ASUS is the one maker in our research that states a noise figure for the Station: approximately 50 dB "in Auto Mode at maximum load without a discrete VGA", with no measurement standard or distance. ASUS, Gigabyte and Supermicro describe closed-loop liquid cooling for the superchip. The makers' pages for the HGX B200 servers in our research give no noise figure; Supermicro lists twelve heavy-duty fans for its 8U system.

ROOMDGX STATION GB300HGX B200 SERVER
Formattower, deskside8U or 10U rack server
Size232 × 584 × 565 mm (ASUS, W × D × H)356 × 449 × 950 mm (Supermicro, H × W × D)
Net weight27 kg (ASUS), 29.2 kg (Gigabyte)133 kg (Supermicro), 91.6 kg (Gigabyte G894)
Operating range10 to 35 °C (ASUS, Gigabyte)10 to 35 °C (Supermicro), 10 to 30 °C (Gigabyte)
Noise figureabout 50 dB under ASUS's conditionsnot published

ASUS tech-spec page and datasheet for the ET900N G3 and Gigabyte's product page for the W775-V10-L01, as cited in our two Station reviews; Supermicro's product page for the SYS-822GS-NBRT and Gigabyte's page for the G894-SD1-AAX5, read 27 November 2026.

The Station stands on the floor or on a desk rated for the load and needs a cord for the outlet at the site. The server needs a rack deep enough for 950 mm in the Supermicro version, a floor and a lift for about 133 kg, and the customer's data-centre staff or a colocation provider to rack and cable it. ASUS's HGX B200 system, the ESC NB8-E11, is a 10U server of 121 kg net without processors, memory and drives. Our site survey for GPU servers lists what to measure before such a delivery.

Software, processors and network

The Station runs an image based on Ubuntu 24.04, which NVIDIA names "Ubuntu with NVIDIA AI Developer Tools", and its Grace CPU uses the Arm v9.0 instruction set, so monitoring, backup and security agents need Arm64 builds. MIG on the Station needs CUDA 13 and an R595 driver from 595.58.03, by NVIDIA's MIG user guide. Its ConnectX-8 SuperNIC has two QSFP112 ports at 400 Gb/s each, and NVIDIA supports linking up to two Stations.

HGX B200 servers use x86 processors chosen by the maker: Supermicro's SYS-822GS-NBRT takes two Intel Xeon 6700 or 6500 series processors, Gigabyte's G894-SD1-AAX5 the same series, and ASUS's ESC NB8-E11 4th or 5th Gen Xeon Scalable. x86 software runs unchanged. The B200 needs CUDA 12.8 or later and an R570 driver, and MIG needs 570.133.20 or later. Supermicro's product page for the SYS-822GS-NBRT lists no ConnectX ports; its brochure "NVIDIA Blackwell Solutions" (December 2025) names eight single-port ConnectX-7 or BlueField-3 SuperNICs at up to 400 Gb/s for it, one per GPU, in the add-on slots. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO.

Service and failure

The Station has one GPU and, in the Gigabyte version, a single power supply, so a driver update, a fault or a tripped circuit stops every user at once. ASUS's product page states "Includes onsite service after remote diagnosis" and says the service varies by country or region. An HGX B200 server has redundant supplies, 3+3 in Supermicro's case, and eight GPUs; warranty and service come from the server maker, as configured in the quote, handled through us. Where the service has to stay up during maintenance, two servers are the usual layout, and our comparison of a GPU server or workstations for a team weighs one shared system against several smaller ones.

Which system fits which team

The DGX Station GB300 fits when:

  • one developer or a small team works on one large model, up to about 208 GiB in HBM3e by our rule;
  • the system has to stand in an office without a server room, on a circuit of its own;
  • models are developed locally and later deployed to a data centre, which NVIDIA's datasheet describes as using "the same tools, libraries, frameworks, and pretrained models";
  • the team's software runs on Arm.

An HGX B200 server fits when:

  • a model service has to serve many users at once, as copies across eight GPUs;
  • a model needs more than 252 GB in GPU memory, up to the 1.4 TB of the board;
  • fine-tuning runs need several GPUs joined by NVLink;
  • a data centre or colocation rack with suitable feeds and cooling is available.

Between the two sit PCIe servers with H200 NVL or RTX PRO 6000 Server Edition cards, which our Station alternatives article compares. Where 1.4 TB is not enough, an HGX B300 server has 2.1 TB; HGX B200 has a considerably shorter lead time than B300, and our sibling article HGX B200 now or HGX B300 later weighs the two.

How either system is ordered from us

We supply the ASUS ExpertCenter Pro ET900N G3 and the Gigabyte W775-V10-L01 per project, on one EU contract and invoice, with the manufacturer warranty handled through us. For an HGX B200 server we need the end user's company, the installation site and the intended use; the server maker and NVIDIA review the project before they confirm it. Our guide to the end-user certificate for NVIDIA GPUs explains the declaration. The steps for the Station are in buying a DGX Station GB300 in the EU, those for the server in our sibling guide to buying an HGX B200 server. Write to us with the system you lean towards and the use you plan, and we reply with the configuration and the next steps.

FAQ

DGX Station vs server: what is the difference?
The DGX Station GB300 is a deskside system with one Blackwell Ultra GPU, 252 GB of HBM3e and 496 GB of LPDDR5X, at 1,600 W of total system power. An HGX B200 server is a rack server with eight B200 GPUs, 1.4 TB of HBM3e as NVIDIA prints it, NVLink at 1.8 TB/s per GPU and power supplies for a data centre.
DGX Station GB300 or B200 server for a team?
The Station suits development and a model service for a small team, on one GPU, with one copy of a model shared by everyone. An HGX B200 server suits a production service for many users, with up to eight copies of a model, and models above 252 GB. By our rule, Llama 3.3 70B in FP8 holds 112 concurrent 8K conversations on the Station and 512 as eight copies on the server.
How much power does a DGX Station need compared with an HGX B200 server?
NVIDIA rates the Station at 1,600 W of total system power, about 7 A at 230 V by our estimate. The eight GPUs of an HGX B200 server alone are configurable up to 1,000 W each, 8 kW together by our multiplication; the makers publish no system figure, and NVIDIA rates its own DGX B200 at 14.3 kW maximum.
Can an HGX B200 server stand in an office?
It is a rack server of 8U or 10U, 133 kg net in Supermicro's version, with power supplies such as six 6,600 W units and twelve heavy-duty fans. It needs a rack, data-centre feeds and cooling. A Station of 27 to 29.2 kg on a 230 V circuit is the deskside option.
How many MIG instances do the DGX Station and an HGX B200 server have?
NVIDIA's MIG user guide lists up to seven instances for the GB300 GPU of the Station, the smallest profile 1g.31gb, and up to seven per B200, the smallest 1g.23gb. An HGX B200 server therefore offers up to 56 instances.
Which DGX Station GB300 versions do you supply?
We supply the ASUS ExpertCenter Pro ET900N G3 and the Gigabyte W775-V10-L01 per project across the EU, on one contract and invoice. The written quote sets out the configuration and the warranty terms.

Send us the models, the number of users and where the system will stand. We answer with the memory arithmetic for a DGX Station GB300 and an HGX B200 server and a quote for the one that fits. We reply within one business day.