Two HGX B200 servers or one HGX B300 server: 16 × B200 against 8 × B300
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- Two HGX B200 servers give 16 B200 GPUs with 2 × 1.4 TB of HBM3e in two NVLink domains of eight; one HGX B300 server gives 8 B300 GPUs with 2.1 TB in one domain, as NVIDIA's HGX page prints them
- Across all GPUs the two B200 servers have more dense FP4 (2 × 72 against 108 PFLOPS) and far more FP64 (2 × 296 against 10 TFLOPS); per GPU and per NVLink domain the B300 is ahead
- A model whose weights and cache exceed one HGX B200, about 1,183 GiB by our rule, must span two servers over the network; one HGX B300 holds about 1,786 GiB in one NVLink domain
- On Supermicro's 8U models the choice is 16U, twelve 6,600 W supplies and 16 network cards against 8U, six supplies and eight ConnectX-8 on the board
- We supply both per project from Supermicro, ASUS, Gigabyte, HPE and Lenovo, after the server maker and NVIDIA have reviewed the project
Supplied by Eurokommerz: HGX B200 servers Request a price →
16 B200 in two servers or 8 B300 in one
Two HGX B200 servers are the better order when the work splits into many model copies, needs FP64, or must keep running while one server is down: 16 GPUs, 2.8 TB of HBM3e in total and twice the dense FP4 of one board. One HGX B300 server is the better order when one model with its cache needs more than an HGX B200 holds, since its 2.1 TB sit in a single NVLink domain, and when one 8U chassis without an east-west fabric suits the site. HGX B200 has a considerably shorter lead time than B300.
The comparison comes up once a B300 quote is on the table and the same budget class could also cover two B200 servers. We publish no prices, so this page compares what the two layouts do. The single-server decision between the generations, with its memory table per model, is in our comparison HGX B200 now or HGX B300 later; this page doubles the B200 side and asks what the second server adds.
We supply HGX B200 servers and HGX B300 servers from Supermicro, ASUS and Gigabyte per project. For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration. Send us the models, their context lengths and the number of users, and we work out which of the two layouts carries them.
Two HGX B200 against one HGX B300, row by row
| ROW | 2 × HGX B200 | 1 × HGX B300 |
|---|---|---|
| GPUs | 16 × B200, 180 GB each | 8 × B300 |
| NVLink domains | two of eight GPUs | one of eight GPUs |
| GPU memory per domain | 1.4 TB | 2.1 TB |
| GPU memory in total | 2.8 TB | 2.1 TB |
| FP4 Tensor, dense | 144 PFLOPS (2 × 72) | 108 PFLOPS |
| FP4 Tensor, sparse | 288 PFLOPS (2 × 144) | 144 PFLOPS |
| FP8 Tensor, dense | 72 PFLOPS (2 × 36) | 36 PFLOPS |
| FP64 | 592 TFLOPS (2 × 296) | 10 TFLOPS |
| Memory bandwidth | 16 × up to 8 TB/s | 8 × up to 8 TB/s |
| Networking bandwidth | 2 × 0.8 TB/s | 1.6 TB/s |
| Compute capability | 10.0 | 10.3 |
NVIDIA HGX platform page, read 27 November 2026, per eight-GPU board (dense FP8 is half the sparse 72 PFLOPS by the page's footnote); memory bandwidth from NVIDIA's HGX AI factory reference architecture, components page (18 May 2026); compute capability from NVIDIA's CUDA GPU list (16 October 2026). Values for two servers are our doubling.
The table shows the trade. Summed over all GPUs, two B200 servers have a third more memory, a third more dense FP4, twice the FP8 and BF16 throughput and 59 times the FP64, by our division. Per GPU the B300 is ahead: 288 GB of HBM3e in NVIDIA's DGX B300 user guide against 180 GB, 13.5 against 9 PFLOPS of dense FP4 by our division, and twice the attention throughput by NVIDIA's rating. The NVLink domain is the boundary that matters most: inside it the GPUs exchange data at 1.8 TB/s each, between the two B200 servers they meet over the cluster network.
One model above 1.4 TB: the case for one HGX B300
Our planning rule takes 90 per cent of a GPU's memory, subtracts 3 GiB per GPU and leaves the rest for weights and KV cache. As our B200-or-B300 comparison works out, that is about 1,183 GiB per HGX B200 server and about 1,786 GiB per HGX B300 server, planning the B300 with the 2.1 TB of NVIDIA's HGX page; the driver on the delivered system decides the exact figure.
A model whose weights and cache fit 1,183 GiB runs on one B200 server, and the second server serves a second copy. A model of about one trillion parameters in FP8, 931.3 GiB of weights, leaves about 252 GiB for cache on an HGX B200 and about 855 GiB on an HGX B300, by the same comparison. Both run it; the B300 holds far more conversations beside it.
Above that the layouts part. At one byte per parameter in FP8, 1,183 GiB is about 1,270 GB, so a model above roughly 1.27 trillion parameters no longer fits one HGX B200 even without any cache, by our arithmetic. Two B200 servers can still run it, split across the network: vLLM's documentation, as our guide to connecting two HGX servers quotes it, sets tensor parallelism to the GPUs per node and pipeline parallelism to the number of nodes, because "Efficient tensor parallelism requires fast internode communication". One 400 Gb/s port carries about 50 GB/s each way against about 900 GB/s of NVLink per GPU by our reading. One HGX B300 keeps such a model inside one NVLink domain up to about 1,786 GiB, roughly 1.9 trillion parameters in FP8 by the same arithmetic, and needs no east-west fabric at all.
Long contexts point the same way. KV cache grows with context length, and attention is the work that NVIDIA rates at twice the B200 on the B300. A service with long prompts, retrieval with many passages or reasoning models with long answers gains on the B300 per GPU, where the second B200 server only adds parallel capacity.
Many copies, FP64 and redundancy: the case for two HGX B200
When each model copy fits one GPU, the count of GPUs decides. Our B200-or-B300 comparison gives Llama 3.3 70B in FP8 64 concurrent sessions of 8,192 tokens per B200 GPU and 124 per B300 GPU, with an FP8 cache. Sixteen B200 GPUs then carry 1,024 sessions and eight B300 GPUs 992, by our estimate; in NVFP4 it is 1,376 against 1,168. The memory bandwidth adds up in the same way: 16 GPUs at up to 8 TB/s each have twice the bandwidth of eight, so with one copy per GPU the sum of the decode ceilings doubles, while one user's token rate stays about the same on either GPU.
FP64 is one-sided. NVIDIA's HGX page lists 296 TFLOPS for each HGX B200 and 10 TFLOPS for the HGX B300, so simulation, CFD or quantum chemistry codes belong on B200 servers; our comparison of FP64 GPU servers sets these figures against other cards.
Two servers are also two failure domains. A failed mainboard, a firmware update or a driver reload stops one server and its eight GPUs, and the other keeps serving. One HGX B300 stops all eight GPUs in the same situations. Our comparison of one 8-GPU server or two 4-GPU servers works through this trade for PCIe servers; the logic is the same one level up.
Data-parallel training spreads well over two servers. Each server holds a full replica in its NVLink domain, and only the gradient exchange crosses the network: a data-parallel LoRA on a 70B model all-reduces about 0.83 GB per GPU and step, about 17 ms at 50 GB/s, as our page on fine-tuning on HGX B200 works out. Fully sharded training of one model across both servers is the case that suffers, because its sharding traffic would cross the network.
If several of these points apply, tell us how many copies, which codes and what uptime the service needs; we answer with the layout and the server configuration.
Rack units, power supplies and network on Supermicro's 8U models
Supermicro builds both boards in the same 8U air-cooled format, which makes the room side easy to compare.
| ITEM | 2 × SYS-822GS-NBRT | 1 × SYS-822GS-NB3RT |
|---|---|---|
| Rack units | 16U (2 × 8U) | 8U |
| Power supplies | 12 × 6,600 W, two 3+3 | 6 × 6,600 W, 3+3 |
| Net weight | 266 kg (2 × 133 kg) | 119 kg |
| GPU power at maximum TDP | 16 × 1,000 W | 8 × 1,100 W |
| GPU network adapters | 16 add-in cards, 400 Gb/s | 8 × ConnectX-8, 800 Gb/s, on board |
| Out-of-band ports, NVIDIA RA | 24 × 1 Gb/s | 6 × 1 Gb/s |
Supermicro product pages SYS-822GS-NBRT and SYS-822GS-NB3RT and brochure "NVIDIA Blackwell Solutions" (December 2025); Supermicro HGX B300 datasheet (©2026) for 1,100 W; NVIDIA HGX B200 carbon footprint summary for "up to 1000 W"; NVIDIA Enterprise Reference Architecture for HGX B200 and B300 (network pages, 31 August and 18 May 2026); read 27 November 2026. Doubled values are our arithmetic.
The GPUs alone come to 16 kW at maximum TDP in two B200 servers and 8.8 kW in one B300 server, by our multiplication. Supermicro's page for its SuperCluster rack SRS-48UAC-B300SX gives "15kW (full load power draw)" per SYS-822GS-NB3RT; for the B200 server Supermicro publishes no system figure on the pages we read. NVIDIA rates its DGX B200 on the same board at 14.3 kW maximum, so two B200 servers belong in the class of about 28.6 kW by that reference and our arithmetic. Plan the feeds with the figures of the configured servers, and see HGX B200 power and cooling for the room.
The network differs in kind. One HGX B300 server needs no compute fabric to run a model on its own eight GPUs; NVIDIA's configuration guide notes that single-node deployments typically do not require high-speed networking, as our article on the ConnectX-8 SuperNIC quotes. Two B200 servers that run one job together need 16 compute links of 400 Gb/s into switches, plus converged and out-of-band ports, by the counts in our guide to connecting two HGX servers. Two servers that only run separate model copies need no east-west fabric either, just their storage and user networks.
Licences and software for 16 or 8 GPUs
NVIDIA AI Enterprise is licensed per GPU, so 16 GPUs need 16 licences where its software runs, against eight for the B300 server; our guide to NVIDIA AI Enterprise licensing covers the counting. Two servers also mean two operating systems, two BMCs and two sets of firmware to keep current. The processor platform inside each server is a separate choice, covered for the B300 in HGX B300 server with AMD EPYC or Intel Xeon 6; if the B200 side began as a DGX B200 quote, DGX B200 alternative maps it onto the makers' servers.
The software targets differ. The B200 has compute capability 10.0; CUDA 12.8 added compiler support for SM_100, and NVIDIA's R570 data-centre driver lists the HGX B200. The B300 has compute capability 10.3; CUDA 12.9 added "compiler target support for SM architecture 10.3", and MIG on the B300 needs an R580 driver of 580.82.07 or later. In practice current serving stacks lift both: vLLM 0.33.0 of 2 November 2026 publishes its release wheels for CUDA 13.0 only, which needs an R580 or newer driver. A fleet that already runs B200 or B300 elsewhere is a reason to stay on that target, as our guide to NVIDIA driver branches and CUDA versions explains.
Which layout for which workload
| WORKLOAD | LAYOUT | WHY |
|---|---|---|
| Many 70B model copies | 2 × HGX B200 | 16 GPUs, 1,024 sessions in FP8 |
| One model above 1,183 GiB | 1 × HGX B300 | stays in one NVLink domain |
| Long contexts, large caches | 1 × HGX B300 | 2.1 TB per domain, 2x attention |
| FP64 simulation | 2 × HGX B200 | 592 against 10 TFLOPS |
| Service that must stay up | 2 × HGX B200 | two failure domains |
| Data-parallel training | 2 × HGX B200 | replicas in NVLink, gradients on fabric |
| One rack position, 8U | 1 × HGX B300 | half the height, six supplies |
| Project with a fixed start | 2 × HGX B200 | considerably shorter lead time |
our assessment from the tables above and the sizing in our B200-or-B300 comparison; session counts are our estimate for Llama 3.3 70B in FP8 at 8,192 tokens with an FP8 cache.
Teams that are undecided have a third route: one HGX B200 server first and the second when the load is known. If the second server may later run one job together with the first, plan the compute fabric for both from the start; our cluster networking guide recommends the leaf layout of NVIDIA's four-server unit for a start that is meant to grow.
Ordering either layout
We quote HGX B200 and HGX B300 servers per project with the maker, processors, memory, drives, network adapters and warranty level as separate lines, and the models of the three makers are side by side in HGX B200 and B300 servers compared. Companies can request our current NVIDIA price list. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO; your data-centre staff or colocation provider rack the servers, and the switches come from your network team. Describe the models, the users and the site, and we answer with both layouts as configurations.
FAQ
Two B200 servers or one B300 server: which is better?
Is 16 × B200 faster than 8 × B300?
How much memory do two HGX B200 servers have compared with one HGX B300?
Can a model be split across two HGX B200 servers?
How much power do two HGX B200 servers need against one HGX B300?
Do two HGX B200 servers need a network switch?
We supply HGX B200 and HGX B300 servers per project. Send us the models, the users and the uptime you need, with the end user's company, the installation site and the intended use. We reply within one business day.
Request a priceWe reply within one business day