  • The alternative to an NVIDIA DGX B200 is an HGX B200 server from a server maker: the same eight B200 GPUs on the same NVIDIA HGX B200 board, so the same 1.4 TB of HBM3e, NVLink and GPU figures as NVIDIA prints them
  • NVIDIA's DGX B200 user guide lists two Xeon Platinum 8570 with 56 cores each, 2 TB of system memory, eight 400 Gb/s ConnectX-7 cards, six 3.3 kW supplies in 5+1, 14.3 kW maximum, 10U and 142.4 kg
  • Supermicro (SYS-822GS-NBRT, AS-A126GS-TNBR), ASUS (ESC NB8-E11) and Gigabyte (G894-SD1-AAX5, G893-SD1-AAX5) choose their own processors, memory slots, drives, power supplies and chassis of 8U or 10U
  • On the makers' B200 servers the eight cluster NICs and the DPUs are add-in cards that the quote lists as separate lines
  • We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project; we do not sell the DGX B200 itself

Supplied by Eurokommerz: HGX B200 servers  Request a price →

The alternative to a DGX B200

The alternative to a DGX B200 is an HGX B200 server from Supermicro, ASUS or Gigabyte. It carries the same NVIDIA HGX B200 board with eight B200 GPUs, 180 GB of HBM3e each, so a model that runs on the DGX B200 runs on it, on the same GPUs with the figures NVIDIA prints for the board. What changes is everything NVIDIA fixed around the board in the DGX: two Xeon Platinum 8570, 2 TB of memory, eight 400 Gb/s ConnectX-7 cards, six 3.3 kW supplies and a 10U chassis of 142.4 kg; on an HGX B200 server the buyer specifies these lines with the maker.

We do not sell the DGX B200. If you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. We supply HGX B200 servers from Supermicro, ASUS and Gigabyte per project, with warranty and service from the server maker, handled through us.

For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration. Send us the DGX B200 configuration you were quoted or planned, and we answer with the HGX B200 models that match it line by line.

This page starts from the DGX B200 and maps each of its lines onto the makers' servers. A single configuration with all its components is described in HGX B200 server specs and configuration, and the software and support layer of DGX against OEM servers in our comparison of DGX B300, HGX B300 and DGX B200.

What is the same: the HGX B200 board

NVIDIA's HGX platform page, read 27 November 2026, gives the HGX B200 eight Blackwell SXM GPUs, 1.4 TB of memory, fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total, 144 PFLOPS of sparse and 72 PFLOPS of dense FP4 and 296 TFLOPS of FP64. NVIDIA's DGX B200 product page and user guide give the DGX 1,440 GB of GPU memory, 64 TB/s of HBM3e bandwidth, the same 144 and 72 PFLOPS of FP4, two NVSwitch chips and 14.4 TB/s of aggregate NVLink. Each B200 is configurable up to 1,000 W, by NVIDIA's HGX B200 carbon footprint summary.

The software targets are the same as well: compute capability 10.0, CUDA 12.8 or later, an R570 or newer driver, and for MIG at least 570.133.20. Code built for the DGX B200 targets the same GPU on an HGX B200 server.

The DGX B200 line by line, and what you specify instead

LINEDGX B200HGX B200 SERVER
GPU board8 × B200, 1,440 GB, 2 × NVSwitchthe same HGX B200 board
Processors2 × Xeon Platinum 8570, 56 cores eachthe maker's platform, by model
System memory2 TB in 32 DIMMs, up to 4 TB24 or 32 slots, module count and speed
Boot drives2 × 1.92 TB NVMe M.2, RAID 1two M.2 slots on every model
Data drives8 × 3.84 TB NVMe U.2, RAID 08 E1.S, or 8 to 10 × 2.5-inch bays
Cluster network4 × OSFP, 8 × ConnectX-7, 400 Gb/seight add-in cards, quote lines
North-south network2 × BlueField-3, dual-port QSFP112DPUs or NICs, quote lines
On-board network10 Gb/s RJ45, 2 × 100 Gb/s, BMC2 × 10 GbE and a BMC port
Power supplies6 × 3.3 kW, 5+16 × 6,600 W to 12 × 3,000 W
System power14.3 kW maximumno figure published by the makers
Height, weight10U, 142.4 kg maximum8U or 10U, 91.6 to 133 kg net
Operating temperature10 to 35 °C10 to 35 °C, Gigabyte 10 to 30 °C

NVIDIA DGX B200 user guide (page updated 17 October 2026) and DGX B200 product page, read 27 November 2026; right column from the makers' pages and datasheets in the tables below, read 27 November 2026.

Processors and memory: five models against the DGX B200

MODELHEIGHTDIMMPOWER SUPPLIESPROCESSORS
NVIDIA DGX B20010U326 × 3.3 kW, 5+12 × Xeon Platinum 8570
Supermicro SYS-822GS-NBRT8U326 × 6,600 W, 3+32 × Xeon 6700/6500, 350 W
Supermicro AS-A126GS-TNBR10U246 × 5,250 W, 3+32 × EPYC 9005/9004, 500 W
ASUS ESC NB8-E1110U326 × 3,000 W, 5+12 × 4th/5th Gen Xeon, 350 W
Gigabyte G894-SD1-AAX58U3212 × 3,000 W, 6+62 × Xeon 6700/6500, 350 W
Gigabyte G893-SD1-AAX58U3212 × 3,000 W, 6+62 × 5th/4th Gen Xeon, 350 W

NVIDIA DGX B200 user guide; Supermicro product pages; ASUS datasheet ESC NB8-E11 (29 May 2025); Gigabyte product pages; read 27 November 2026. Processor wattage is the maximum TDP per socket.

The DGX's 112 cores at 2.1 GHz base and up to 4 GHz boost are a fixed choice. The makers give a range: Supermicro lists up to 86 cores per Xeon 6700/6500 processor on the SYS-822GS-NBRT and up to 384 cores per system with EPYC on the AS-A126GS-TNBR. Gigabyte's G894 takes Xeon 6, its G893 and the ASUS ESC NB8-E11 stay on 4th or 5th Gen Xeon Scalable. Which processor fits the host work, and when software licensed per core argues for fewer cores, is covered in our guide to the CPU for a GPU server, and the same choice on the B300 board in HGX B300 server with AMD EPYC or Intel Xeon 6.

System memory comes in different steps per model. The SYS-822GS-NBRT takes up to 4 TB at 6400 MT/s with one module per channel and up to 8 TB at 5200 MT/s with two, so the DGX's 2 TB can be built as 16 modules of 128 GB at full speed or 32 of 64 GB at the lower speed, by our arithmetic. The AS-A126GS-TNBR has 24 slots, one per channel, for up to 6 TB at 6400 MT/s with EPYC 9005; with one module in each channel the even steps near 2 TB are 1,536 GB and 2,304 GB, as our guide to how much RAM a GPU server needs lists for 24 channels. Gigabyte's G894-SD1-AAX5 runs RDIMM at 6400 MT/s with one module per channel and 6000 MT/s with two, or MRDIMM at 8000 MT/s. The ESC NB8-E11 datasheet prints both DDR5-5600 and DDR5-4400 and up to 4 TB per CPU, so the speed belongs in the quote.

Drives and slots

The DGX B200 splits storage into a mirrored pair of 1.92 TB M.2 drives for the operating system and eight 3.84 TB U.2 drives in RAID 0 as data cache. Every model here has two M.2 slots for the boot pair, but the data bays differ: eight E1.S bays on the SYS-822GS-NBRT, ten 2.5-inch bays (eight NVMe, two SATA) or eight E1.S on the AS-A126GS-TNBR, ten 2.5-inch bays (eight NVMe, two NVMe or SATA) on the ESC NB8-E11, and eight 2.5-inch bays on both Gigabyte models, Gen5 NVMe on the G894 and NVMe or SATA on the G893. A configuration that copies the DGX therefore names the drive format as well as the capacity. On the G893 and the ESC NB8-E11 the M.2 slots hang on the chipset at Gen3, while the SYS-822GS-NBRT and the G894 take Gen5.

The slot count follows the chassis. Supermicro lists eight PCIe 5.0 x16 low-profile and two full-height half-length slots on both of its models. ASUS has eight Gen5 x16 slots behind a PCIe switch, two CPU-direct Gen5 x16 slots and one Gen4 x8. Gigabyte has twelve full-height half-length Gen5 x16 slots on both models.

Network: the DGX's eight ConnectX-7 become quote lines

NVIDIA's DGX B200 brings its cluster network with it: "4 x OSFP ports for 8 x NVIDIA ConnectX-7 Single Port Cards" at up to 400 Gb/s, InfiniBand or Ethernet, and two dual-port QSFP112 BlueField-3 DPUs at up to 400 Gb/s for storage and north-south traffic. These are PCIe cards in the DGX as well; we found no NVIDIA document that places network adapters on the HGX B200 board itself.

On the makers' servers the same function is a list of add-in cards. Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives the SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s)" and two dual-port BlueField-3 DPUs at a "1:1 GPU-to-NIC ratio", while the product page lists only the slots. ASUS routes the eight switch slots of the ESC NB8-E11 for up to one NIC per GPU and adds that BlueField-3 limits the operating temperature to 30 °C when transceivers are used. Gigabyte names ConnectX-7 and BlueField-3 as compatible with its G893 and G894 but does not say which slot takes which card.

For a DGX-like configuration the quote therefore lists eight 400 Gb/s adapters, two DPUs or dual-port NICs, the transceivers and the cables. A single server that runs complete models on its own eight GPUs needs none of the eight cluster cards; two or more servers that share one job do, as our guide to connecting two HGX servers counts.

Power supplies and the 14.3 kW figure

NVIDIA rates the DGX B200 at "14.3 kW max." with six 3.3 kW supplies. Its user guide gives each supply "3,300 W @ 200-240 V, 16 A, 50-60 Hz", configures the six "for 5+1 redundancy", states that the system "only boots if at least three PSUs are operational" and asks to "only use the NVIDIA-provided power cords" of C19/C20 type rated 250 V AC and 20 A.

The makers' supplies are larger or more numerous. Supermicro's SYS-822GS-NBRT has six 6,600 W supplies as 3+3; each gives 6,500 W at 230 to 238.9 V and 5,900 W at 200 to 207.9 V. The AS-A126GS-TNBR has six 5,250 W supplies as 3+3 for 200 to 240 V. ASUS fits six 3,000 W supplies as 5+1 and prints no input voltage. Gigabyte fits twelve 3,000 W supplies as 6+6, each giving 2,900 W at 200 to 220 V and 3,002.4 W at 220 to 240 V, with C19 cords not included.

None of the three makers publishes a system power figure for its HGX B200 server on the pages we read. Eight B200 at up to 1,000 W are 8 kW for the GPUs alone by our multiplication, and the DGX B200's 14.3 kW is the nearest published reference for the whole system. On two feeds, 3+3 and 6+6 layouts keep the server running when one feed fails; 5+1, on the DGX and on the ESC NB8-E11, does not carry full load through a feed loss by our reading, as PSU redundancy in GPU servers explains. Feeds and cooling for these servers are in HGX B200 power and cooling.

Height, depth and weight

The DGX B200 is a 10U system, 444 mm high, 482.3 mm wide and 897.1 mm deep, and weighs up to 142.4 kg. The makers' models are lighter and differ in depth. Supermicro's SYS-822GS-NBRT takes 8U at 950 mm depth and weighs 133 kg net; the AS-A126GS-TNBR takes 10U, 843.28 mm deep, at the same 133 kg net. The ESC NB8-E11 measures 885 × 447 × 435.95 mm, axes not labelled in the datasheet, and weighs 121 kg net without processors, memory and drives. Gigabyte's 8U chassis is 923 mm deep; the G894-SD1-AAX5 weighs 91.6 kg net as printed, and the G893-SD1-AAX5 page gives no weight.

Two consequences for the rack. A rack planned around the DGX's 897.1 mm needs its depth checked for the 923 mm and 950 mm models. And Gigabyte's operating range of 10 to 30 °C is five degrees below the DGX's and the other makers' 35 °C, which matters in halls with warm supply air; our article on GPU server inlet temperature covers the measurement.

Software and support in two sentences

The DGX B200 adds DGX OS, which NVIDIA licenses only for use in DGX systems, NVIDIA's support contract and NVIDIA Mission Control, whose 2.5.0 release notes state that "HGX B200 and HGX B300 from OEMs are not supported". On an HGX B200 server you choose the operating system and driver branch, warranty and service come from the server maker, and Base Command Manager, included with NVIDIA AI Enterprise, manages clusters; NVIDIA Mission Control: what DGX buyers get covers these layers in detail.

Ordering an HGX B200 server in place of a DGX B200

PRIORITYMODELS TO LOOK AT
Closest to the DGX in heightSupermicro AS-A126GS-TNBR, ASUS ESC NB8-E11
Least rack heightSupermicro SYS-822GS-NBRT, Gigabyte G894
AMD processorsSupermicro AS-A126GS-TNBR
Newest Intel platformSupermicro SYS-822GS-NBRT, Gigabyte G894
Most PCIe slotsGigabyte G894-SD1-AAX5, G893-SD1-AAX5
Supply air up to 35 °CSupermicro, ASUS

our reading of the makers' pages in the tables above, read 27 November 2026; not a ranking by the makers.

Your data-centre staff or the colocation provider rack and cable the server. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO; hardware service on site comes from the server maker as configured in the quote. If an HGX B300 quote is also on the table, two HGX B200 servers or one HGX B300 compares the two layouts. The order steps are in buying an HGX B200 server, and the makers' models side by side in HGX B200 and B300 servers compared. Companies can request our current NVIDIA price list. Tell us the rack, the feeds and the processor platform you prefer, and we configure the HGX B200 server with the maker.

FAQ

What is the alternative to the NVIDIA DGX B200?
An HGX B200 server from a server maker, such as Supermicro's SYS-822GS-NBRT or AS-A126GS-TNBR, ASUS's ESC NB8-E11 or Gigabyte's G894-SD1-AAX5 and G893-SD1-AAX5. They carry the same eight B200 GPUs on the same NVIDIA HGX B200 board, with the maker's processors, memory, power supplies and chassis.
DGX B200 vs HGX B200: what is the difference?
HGX B200 is NVIDIA's eight-GPU board. The DGX B200 is NVIDIA's own 10U server built on it, with two Xeon Platinum 8570, 2 TB of memory, eight ConnectX-7 cards, DGX OS and NVIDIA support. HGX B200 servers are the makers' servers on the same board, with their own platform and service.
Where can I buy a DGX B200?
NVIDIA sells DGX systems through its certified DGX partners. We do not sell the DGX B200; we supply HGX B200 servers from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo per project, with warranty and service from the server maker handled through us.
Is an HGX B200 server as fast as a DGX B200?
Both carry the same eight B200 GPUs: NVIDIA prints 144 PFLOPS of sparse and 72 PFLOPS of dense FP4 and 14.4 TB/s of NVLink for the HGX B200 board and for the DGX B200. Processors, system memory, drives and network cards around the board differ by model and configuration.
Which CPU does the DGX B200 use?
Two Intel Xeon Platinum 8570 with 56 cores each, 112 in total, at 2.1 GHz base and up to 4 GHz boost, with 2 TB of system memory in 32 DIMMs, upgradable to 4 TB, by NVIDIA's DGX B200 user guide.
How much power does an HGX B200 server need compared with a DGX B200?
NVIDIA rates the DGX B200 at 14.3 kW maximum. The makers publish no system figure for their HGX B200 servers; eight B200 at up to 1,000 W are 8 kW for the GPUs alone by our arithmetic, so plan in the DGX's class until the configured server's figures are known.

We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo per project as the alternative to a DGX B200. Send us the end user's company, the installation site, the intended use and the configuration you need. We reply within one business day.