DGX B200 alternative: HGX B200 servers from Supermicro, ASUS and Gigabyte, line by line
Eurokommerz, Vienna, since 2006: Private AI/ML · IT Managed Services · Enterprise Training · AI Hardware & Software
- The alternative to an NVIDIA DGX B200 is an HGX B200 server from a server maker: the same eight B200 GPUs on the same NVIDIA HGX B200 board, so the same 1.4 TB of HBM3e, NVLink and GPU figures as NVIDIA prints them
- NVIDIA's DGX B200 user guide lists two Xeon Platinum 8570 with 56 cores each, 2 TB of system memory, eight 400 Gb/s ConnectX-7 cards, six 3.3 kW supplies in 5+1, 14.3 kW maximum, 10U and 142.4 kg
- Supermicro (SYS-822GS-NBRT, AS-A126GS-TNBR), ASUS (ESC NB8-E11) and Gigabyte (G894-SD1-AAX5, G893-SD1-AAX5) choose their own processors, memory slots, drives, power supplies and chassis of 8U or 10U
- On the makers' B200 servers the eight cluster NICs and the DPUs are add-in cards that the quote lists as separate lines
- We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project; we do not sell the DGX B200 itself
Supplied by Eurokommerz: HGX B200 servers Request a price →
The alternative to a DGX B200
The alternative to a DGX B200 is an HGX B200 server from Supermicro, ASUS or Gigabyte. It carries the same NVIDIA HGX B200 board with eight B200 GPUs, 180 GB of HBM3e each, so a model that runs on the DGX B200 runs on it, on the same GPUs with the figures NVIDIA prints for the board. What changes is everything NVIDIA fixed around the board in the DGX: two Xeon Platinum 8570, 2 TB of memory, eight 400 Gb/s ConnectX-7 cards, six 3.3 kW supplies and a 10U chassis of 142.4 kg; on an HGX B200 server the buyer specifies these lines with the maker.
We do not sell the DGX B200. If you specifically need a DGX system with NVIDIA support, it is sold through NVIDIA's certified DGX partners. We supply HGX B200 servers from Supermicro, ASUS and Gigabyte per project, with warranty and service from the server maker, handled through us.
For an order we need the end user's company, the installation site and the intended use, and the server maker and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration. Send us the DGX B200 configuration you were quoted or planned, and we answer with the HGX B200 models that match it line by line.
This page starts from the DGX B200 and maps each of its lines onto the makers' servers. A single configuration with all its components is described in HGX B200 server specs and configuration, and the software and support layer of DGX against OEM servers in our comparison of DGX B300, HGX B300 and DGX B200.
What is the same: the HGX B200 board
NVIDIA's HGX platform page, read 27 November 2026, gives the HGX B200 eight Blackwell SXM GPUs, 1.4 TB of memory, fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total, 144 PFLOPS of sparse and 72 PFLOPS of dense FP4 and 296 TFLOPS of FP64. NVIDIA's DGX B200 product page and user guide give the DGX 1,440 GB of GPU memory, 64 TB/s of HBM3e bandwidth, the same 144 and 72 PFLOPS of FP4, two NVSwitch chips and 14.4 TB/s of aggregate NVLink. Each B200 is configurable up to 1,000 W, by NVIDIA's HGX B200 carbon footprint summary.
The software targets are the same as well: compute capability 10.0, CUDA 12.8 or later, an R570 or newer driver, and for MIG at least 570.133.20. Code built for the DGX B200 targets the same GPU on an HGX B200 server.
The DGX B200 line by line, and what you specify instead
| LINE | DGX B200 | HGX B200 SERVER |
|---|---|---|
| GPU board | 8 × B200, 1,440 GB, 2 × NVSwitch | the same HGX B200 board |
| Processors | 2 × Xeon Platinum 8570, 56 cores each | the maker's platform, by model |
| System memory | 2 TB in 32 DIMMs, up to 4 TB | 24 or 32 slots, module count and speed |
| Boot drives | 2 × 1.92 TB NVMe M.2, RAID 1 | two M.2 slots on every model |
| Data drives | 8 × 3.84 TB NVMe U.2, RAID 0 | 8 E1.S, or 8 to 10 × 2.5-inch bays |
| Cluster network | 4 × OSFP, 8 × ConnectX-7, 400 Gb/s | eight add-in cards, quote lines |
| North-south network | 2 × BlueField-3, dual-port QSFP112 | DPUs or NICs, quote lines |
| On-board network | 10 Gb/s RJ45, 2 × 100 Gb/s, BMC | 2 × 10 GbE and a BMC port |
| Power supplies | 6 × 3.3 kW, 5+1 | 6 × 6,600 W to 12 × 3,000 W |
| System power | 14.3 kW maximum | no figure published by the makers |
| Height, weight | 10U, 142.4 kg maximum | 8U or 10U, 91.6 to 133 kg net |
| Operating temperature | 10 to 35 °C | 10 to 35 °C, Gigabyte 10 to 30 °C |
NVIDIA DGX B200 user guide (page updated 17 October 2026) and DGX B200 product page, read 27 November 2026; right column from the makers' pages and datasheets in the tables below, read 27 November 2026.
Processors and memory: five models against the DGX B200
| MODEL | HEIGHT | DIMM | POWER SUPPLIES | PROCESSORS |
|---|---|---|---|---|
| NVIDIA DGX B200 | 10U | 32 | 6 × 3.3 kW, 5+1 | 2 × Xeon Platinum 8570 |
| Supermicro SYS-822GS-NBRT | 8U | 32 | 6 × 6,600 W, 3+3 | 2 × Xeon 6700/6500, 350 W |
| Supermicro AS-A126GS-TNBR | 10U | 24 | 6 × 5,250 W, 3+3 | 2 × EPYC 9005/9004, 500 W |
| ASUS ESC NB8-E11 | 10U | 32 | 6 × 3,000 W, 5+1 | 2 × 4th/5th Gen Xeon, 350 W |
| Gigabyte G894-SD1-AAX5 | 8U | 32 | 12 × 3,000 W, 6+6 | 2 × Xeon 6700/6500, 350 W |
| Gigabyte G893-SD1-AAX5 | 8U | 32 | 12 × 3,000 W, 6+6 | 2 × 5th/4th Gen Xeon, 350 W |
NVIDIA DGX B200 user guide; Supermicro product pages; ASUS datasheet ESC NB8-E11 (29 May 2025); Gigabyte product pages; read 27 November 2026. Processor wattage is the maximum TDP per socket.
The DGX's 112 cores at 2.1 GHz base and up to 4 GHz boost are a fixed choice. The makers give a range: Supermicro lists up to 86 cores per Xeon 6700/6500 processor on the SYS-822GS-NBRT and up to 384 cores per system with EPYC on the AS-A126GS-TNBR. Gigabyte's G894 takes Xeon 6, its G893 and the ASUS ESC NB8-E11 stay on 4th or 5th Gen Xeon Scalable. Which processor fits the host work, and when software licensed per core argues for fewer cores, is covered in our guide to the CPU for a GPU server, and the same choice on the B300 board in HGX B300 server with AMD EPYC or Intel Xeon 6.
System memory comes in different steps per model. The SYS-822GS-NBRT takes up to 4 TB at 6400 MT/s with one module per channel and up to 8 TB at 5200 MT/s with two, so the DGX's 2 TB can be built as 16 modules of 128 GB at full speed or 32 of 64 GB at the lower speed, by our arithmetic. The AS-A126GS-TNBR has 24 slots, one per channel, for up to 6 TB at 6400 MT/s with EPYC 9005; with one module in each channel the even steps near 2 TB are 1,536 GB and 2,304 GB, as our guide to how much RAM a GPU server needs lists for 24 channels. Gigabyte's G894-SD1-AAX5 runs RDIMM at 6400 MT/s with one module per channel and 6000 MT/s with two, or MRDIMM at 8000 MT/s. The ESC NB8-E11 datasheet prints both DDR5-5600 and DDR5-4400 and up to 4 TB per CPU, so the speed belongs in the quote.
Drives and slots
The DGX B200 splits storage into a mirrored pair of 1.92 TB M.2 drives for the operating system and eight 3.84 TB U.2 drives in RAID 0 as data cache. Every model here has two M.2 slots for the boot pair, but the data bays differ: eight E1.S bays on the SYS-822GS-NBRT, ten 2.5-inch bays (eight NVMe, two SATA) or eight E1.S on the AS-A126GS-TNBR, ten 2.5-inch bays (eight NVMe, two NVMe or SATA) on the ESC NB8-E11, and eight 2.5-inch bays on both Gigabyte models, Gen5 NVMe on the G894 and NVMe or SATA on the G893. A configuration that copies the DGX therefore names the drive format as well as the capacity. On the G893 and the ESC NB8-E11 the M.2 slots hang on the chipset at Gen3, while the SYS-822GS-NBRT and the G894 take Gen5.
The slot count follows the chassis. Supermicro lists eight PCIe 5.0 x16 low-profile and two full-height half-length slots on both of its models. ASUS has eight Gen5 x16 slots behind a PCIe switch, two CPU-direct Gen5 x16 slots and one Gen4 x8. Gigabyte has twelve full-height half-length Gen5 x16 slots on both models.
Network: the DGX's eight ConnectX-7 become quote lines
NVIDIA's DGX B200 brings its cluster network with it: "4 x OSFP ports for 8 x NVIDIA ConnectX-7 Single Port Cards" at up to 400 Gb/s, InfiniBand or Ethernet, and two dual-port QSFP112 BlueField-3 DPUs at up to 400 Gb/s for storage and north-south traffic. These are PCIe cards in the DGX as well; we found no NVIDIA document that places network adapters on the HGX B200 board itself.
On the makers' servers the same function is a list of add-in cards. Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives the SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s)" and two dual-port BlueField-3 DPUs at a "1:1 GPU-to-NIC ratio", while the product page lists only the slots. ASUS routes the eight switch slots of the ESC NB8-E11 for up to one NIC per GPU and adds that BlueField-3 limits the operating temperature to 30 °C when transceivers are used. Gigabyte names ConnectX-7 and BlueField-3 as compatible with its G893 and G894 but does not say which slot takes which card.
For a DGX-like configuration the quote therefore lists eight 400 Gb/s adapters, two DPUs or dual-port NICs, the transceivers and the cables. A single server that runs complete models on its own eight GPUs needs none of the eight cluster cards; two or more servers that share one job do, as our guide to connecting two HGX servers counts.
Power supplies and the 14.3 kW figure
NVIDIA rates the DGX B200 at "14.3 kW max." with six 3.3 kW supplies. Its user guide gives each supply "3,300 W @ 200-240 V, 16 A, 50-60 Hz", configures the six "for 5+1 redundancy", states that the system "only boots if at least three PSUs are operational" and asks to "only use the NVIDIA-provided power cords" of C19/C20 type rated 250 V AC and 20 A.
The makers' supplies are larger or more numerous. Supermicro's SYS-822GS-NBRT has six 6,600 W supplies as 3+3; each gives 6,500 W at 230 to 238.9 V and 5,900 W at 200 to 207.9 V. The AS-A126GS-TNBR has six 5,250 W supplies as 3+3 for 200 to 240 V. ASUS fits six 3,000 W supplies as 5+1 and prints no input voltage. Gigabyte fits twelve 3,000 W supplies as 6+6, each giving 2,900 W at 200 to 220 V and 3,002.4 W at 220 to 240 V, with C19 cords not included.
None of the three makers publishes a system power figure for its HGX B200 server on the pages we read. Eight B200 at up to 1,000 W are 8 kW for the GPUs alone by our multiplication, and the DGX B200's 14.3 kW is the nearest published reference for the whole system. On two feeds, 3+3 and 6+6 layouts keep the server running when one feed fails; 5+1, on the DGX and on the ESC NB8-E11, does not carry full load through a feed loss by our reading, as PSU redundancy in GPU servers explains. Feeds and cooling for these servers are in HGX B200 power and cooling.
Height, depth and weight
The DGX B200 is a 10U system, 444 mm high, 482.3 mm wide and 897.1 mm deep, and weighs up to 142.4 kg. The makers' models are lighter and differ in depth. Supermicro's SYS-822GS-NBRT takes 8U at 950 mm depth and weighs 133 kg net; the AS-A126GS-TNBR takes 10U, 843.28 mm deep, at the same 133 kg net. The ESC NB8-E11 measures 885 × 447 × 435.95 mm, axes not labelled in the datasheet, and weighs 121 kg net without processors, memory and drives. Gigabyte's 8U chassis is 923 mm deep; the G894-SD1-AAX5 weighs 91.6 kg net as printed, and the G893-SD1-AAX5 page gives no weight.
Two consequences for the rack. A rack planned around the DGX's 897.1 mm needs its depth checked for the 923 mm and 950 mm models. And Gigabyte's operating range of 10 to 30 °C is five degrees below the DGX's and the other makers' 35 °C, which matters in halls with warm supply air; our article on GPU server inlet temperature covers the measurement.
Software and support in two sentences
The DGX B200 adds DGX OS, which NVIDIA licenses only for use in DGX systems, NVIDIA's support contract and NVIDIA Mission Control, whose 2.5.0 release notes state that "HGX B200 and HGX B300 from OEMs are not supported". On an HGX B200 server you choose the operating system and driver branch, warranty and service come from the server maker, and Base Command Manager, included with NVIDIA AI Enterprise, manages clusters; NVIDIA Mission Control: what DGX buyers get covers these layers in detail.
Ordering an HGX B200 server in place of a DGX B200
| PRIORITY | MODELS TO LOOK AT |
|---|---|
| Closest to the DGX in height | Supermicro AS-A126GS-TNBR, ASUS ESC NB8-E11 |
| Least rack height | Supermicro SYS-822GS-NBRT, Gigabyte G894 |
| AMD processors | Supermicro AS-A126GS-TNBR |
| Newest Intel platform | Supermicro SYS-822GS-NBRT, Gigabyte G894 |
| Most PCIe slots | Gigabyte G894-SD1-AAX5, G893-SD1-AAX5 |
| Supply air up to 35 °C | Supermicro, ASUS |
our reading of the makers' pages in the tables above, read 27 November 2026; not a ranking by the makers.
Your data-centre staff or the colocation provider rack and cable the server. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO; hardware service on site comes from the server maker as configured in the quote. If an HGX B300 quote is also on the table, two HGX B200 servers or one HGX B300 compares the two layouts. The order steps are in buying an HGX B200 server, and the makers' models side by side in HGX B200 and B300 servers compared. Companies can request our current NVIDIA price list. Tell us the rack, the feeds and the processor platform you prefer, and we configure the HGX B200 server with the maker.
FAQ
What is the alternative to the NVIDIA DGX B200?
DGX B200 vs HGX B200: what is the difference?
Where can I buy a DGX B200?
Is an HGX B200 server as fast as a DGX B200?
Which CPU does the DGX B200 use?
How much power does an HGX B200 server need compared with a DGX B200?
We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, Dell, HPE and Lenovo per project as the alternative to a DGX B200. Send us the end user's company, the installation site, the intended use and the configuration you need. We reply within one business day.
Request a priceWe reply within one business day