- The Supermicro SYS-822GS-NBRT is an 8U air-cooled server on NVIDIA HGX B200: eight B200 GPUs with 180 GB each at "1000W TDP per GPU", two Intel Xeon 6700/6500 P-core processors of up to 350 W and 32 DIMM slots
- System memory runs at 6400 MT/s with one DIMM per channel (up to 4 TB) and at 5200 MT/s with two (up to 8 TB), as Supermicro's product page and datasheet page print it
- The product page lists no cluster network adapters, only eight PCIe 5.0 x16 low-profile slots; Supermicro's brochure of December 2025 pairs every GPU with a single-port 400 Gb/s ConnectX-7 or BlueField-3 SuperNIC
- Six 6,600 W Titanium supplies run as 3+3 and deliver 6,500 W each at 230 to 238.9 V; the chassis is 356 × 449 × 950 mm and 133 kg net, and Supermicro publishes no system power figure
- We supply HGX B200 servers such as this one per project; for an order we need the end user's company, the installation site and the intended use
Supplied by Eurokommerz: HGX B200 servers Request a price →
Supermicro SYS-822GS-NBRT: what the model page lists
The Supermicro SYS-822GS-NBRT is Supermicro's 8U air-cooled server on the NVIDIA HGX B200 board: eight B200 GPUs with 180 GB of HBM3e each, two Intel Xeon 6700/6500-series processors with P-cores and 32 DIMM slots for up to 8 TB of DDR5. Its product page and datasheet page, read 27 November 2026, list six 6,600 W power supplies as 3+3, a chassis of 356 × 449 × 950 mm and 133 kg net. The page names no network adapters for the GPU cluster and no system power figure, so both are settled in the configuration.
Supermicro describes the model as "DP Intel 8U System with NVIDIA HGX B200 8-GPU supporting 32 DIMMs" and lists a single SKU, without the pre-configured variants it offers for the B300 version. One character separates the names: the SYS-822GS-NB3RT carries the HGX B300 board. The two servers also differ in the chassis details. The B300 model has eight ConnectX-8 SuperNICs with OSFP ports built in, weighs 119 kg net and prints 6000 MT/s for two DIMMs per channel; our review of the Supermicro SYS-822GS-NB3RT covers it.
We supply HGX B200 servers from Supermicro, ASUS, Gigabyte, HPE and Lenovo per project, this model among them. Before we quote, we need the end user's company, the installation site and the intended use, and Supermicro and NVIDIA review the project before they confirm it; our guide to the end-user certificate for NVIDIA GPUs explains the declaration. Send us these three with the number of servers, and we come back with the questions the configuration needs answered.
The HGX B200 board and what Supermicro adds around it
Supermicro lists the board as "HGX B200 8-GPU (180GB)" with "1000W TDP per GPU, air cooled" and NVLink through NVSwitch. It prints no total for the eight GPUs. By our arithmetic 8 × 180 GB is 1,440 GB, and NVIDIA's HGX platform page, read 27 November 2026, prints 1.4 TB, with fifth-generation NVLink at 1.8 TB/s per GPU and 14.4 TB/s in total, 72 PFLOPS of dense FP4 Tensor Core throughput (144 PFLOPS sparse) and 296 TFLOPS of FP64. The 1,000 W per GPU is the ceiling in NVIDIA's HGX B200 carbon footprint summary (July 2025), which calls the TDP "configurable up to 1000 W".
Everything else is Supermicro's: the X14DBG-LC+ motherboard and the CSE-GP807TS-R000NP-B2 chassis named on the page, the processors, memory, drives, slots, fans and supplies. Supermicro calls the result an "8U air-cooled Front I/O system". A line-by-line HGX B200 configuration with NVIDIA's DGX B200 beside it is in our article on HGX B200 server specs; this review stays with what is particular to this chassis.
Processors and system memory: one or two DIMMs per channel
The board takes two Intel Xeon 6700 or 6500-series processors with P-cores in LGA-4710 (Socket E2), each with up to 86 cores, 172 threads, 336 MB of cache and 350 W. The memory speed depends on how the 32 slots are filled.
| POPULATION | MODULES | MAXIMUM | SPEED |
|---|---|---|---|
| 1 DIMM per channel | 16 | 4 TB DDR5 ECC RDIMM | 6400 MT/s |
| 2 DIMMs per channel | 32 | 8 TB | 5200 MT/s |
Supermicro product page and datasheet page for the SYS-822GS-NBRT (©2026, no revision date), read 27 November 2026; module counts are our reading of 32 slots on two sockets.
Both Supermicro pages for this model give 5200 MT/s for two modules per channel. The SYS-822GS-NB3RT in the B300 line and the liquid-cooled SYS-422GS-NBRT-LCC on the same B200 board print 6000 MT/s for the same population. Three related servers, two speeds: have the quote state the module size, the module count and the speed it was planned with. By our arithmetic the 4 TB at full speed takes sixteen 256 GB modules. How much system memory eight B200 GPUs call for under NVIDIA's sizing rule is worked out in the specs article linked above.
Drives and ten PCIe 5.0 slots
Storage sits in eight front hot-swap E1.S NVMe bays, with two M.2 PCIe 5.0 x4 NVMe slots (2280 or 22110) for the operating system and RAID through an S3808N controller. On board there are two 10GbE RJ45 ports on an Intel X710 and one 1 GbE port for IPMI and the BMC. Expansion is listed as "Up to 8 PCIe 5.0 x16 LP + 2 PCIe 5.0 x16 FHHL".
The eight E1.S bays hold the model weights in service and the scratch data of training runs; datasets that several servers share belong on network storage.
The eight 400G network cards are a line in the quote
This is the point where the B200 model differs most from its B300 sibling. The product page lists no ConnectX adapter and no OSFP port. Supermicro's brochure "NVIDIA Blackwell Solutions" (December 2025) gives the SYS-822GS-NBRT "8 single-port ConnectX-7 or BlueField-3 SuperNICs (up to 400Gb/s); 2 dual-port BlueField-3 DPUs" with a "1:1 GPU-to-NIC ratio". In our reading the eight low-profile slots match the eight SuperNICs and the two full-height slots the two DPUs, but neither page assigns them in one sentence, and the product page does not say whether the cards are part of a standard configuration.
NVIDIA's own reference design differs in the details. Its Enterprise Reference Architecture for HGX B200 on Spectrum-X Ethernet (last updated 31 August 2026) puts "Eight BlueField-3 B3140H single-port 400 GbE SuperNIC" on the compute network and "One BlueField-3 B3220 dual port 200 GbE DPU" on the converged north-south network of each node. Which design your cluster follows decides the cards, the transceivers and the switch ports.
NVIDIA's configuration guide, as our specs article quotes it, says that single-node deployments typically do not require high-speed networking; two or more servers that train one model together need all eight cluster links. Our article on two HGX servers in a cluster covers the switches and cabling, and BlueField-3 DPU in GPU servers the storage side. If you already know the fabric, tell us the switch model and the number of servers, and the NIC lines of the quote are planned to match it.
Power supplies per voltage band
Six hot-swap supplies of 6,600 W each run as 3+3, rated "Titanium Level (96%)". Their output depends on the input voltage, so the supply rating at your rack is lower than the nominal figure unless the feed sits at 239 to 240 V.
| INPUT VOLTAGE | PER SUPPLY | THREE SUPPLIES |
|---|---|---|
| 200 to 207.9 V | 5,900 W | 17.7 kW |
| 208 to 219.9 V | 6,000 W | 18.0 kW |
| 220 to 229.9 V | 6,300 W | 18.9 kW |
| 230 to 238.9 V | 6,500 W | 19.5 kW |
| 239 to 240 V | 6,600 W | 19.8 kW |
Supermicro product page for the SYS-822GS-NBRT, read 27 November 2026, every band at 50 to 60 Hz; third column our multiplication, the capacity of the three supplies that carry the server in 3+3, not a power draw.
Supermicro publishes no system power figure for this server. The eight GPUs alone come to up to 8 kW at 1,000 W each by our multiplication, and the nearest whole-system figure is NVIDIA's rating of 14.3 kW maximum for its own DGX B200 on the same board (DGX B200 user guide, updated 17 October 2026). The table shows why a 230 V feed matters: the three supplies that carry the load have 19.5 kW there and 17.7 kW at the bottom of the range. The product page names neither the inlet nor the cord type. Feeds, connectors and the A and B sides are covered in our guide to HGX B200 power and cooling.
Chassis, weight and air
The chassis measures 356 × 449 × 950 mm (13.8 × 17.6 × 37.4 in) and comes in a package of 670 × 730 × 1,280 mm. Supermicro's product page and datasheet page agree on 133 kg net and 155 kg gross (293 and 341 lb). That is 14 kg more net weight than the SYS-822GS-NB3RT by our subtraction, although the B300 model carries its network adapters on the board; Supermicro gives no reason for the difference.
Twelve heavy-duty fans and an air shroud cool the server. Supermicro gives an operating range of 10 °C to 35 °C at 8 to 90 per cent relative humidity, non-condensing, where the B300 page prints 8 to 80 per cent, and a non-operating range of -40 °C to 70 °C. The 950 mm depth is more than the 897.1 mm of NVIDIA's DGX B200, so a rack measured for a DGX is not automatically deep enough. Our site survey for GPU servers lists what to measure on the way from the loading bay to the rack.
The AMD 10U sibling and the 4U liquid-cooled version
Supermicro builds the same board into two more chassis worth knowing before a model is chosen.
| ITEM | SYS-822GS-NBRT | AS-A126GS-TNBR | SYS-422GS-NBRT-LCC |
|---|---|---|---|
| Height and cooling | 8U, air | 10U, air | 4U, liquid, direct to chip |
| Processors | 2 × Xeon 6700/6500, 350 W | 2 × EPYC 9005/9004, 500 W | 2 × Xeon 6700P, 350 W |
| Memory | 32 DIMMs, 8 TB at 5200 MT/s | 24 DIMMs, 6 TB at 1DPC | 32 DIMMs, 8 TB at 6000 MT/s |
| Front drives | 8 × E1.S NVMe | 10 × 2.5 in or 8 × E1.S | 8 × E1.S NVMe |
| PCIe slots | 8 × LP, 2 × FHHL | 8 × LP, 2 × FHHL | 8 × LP, 2 × FHHL |
| Power supplies | 6 × 6,600 W, 3+3 | 6 × 5,250 W, 3+3 | 4 × 6,600 W, 2+2 |
| H × W × D | 356 × 449 × 950 mm | 438.8 × 449 × 843.28 mm | 174 × 448 × 991.4 mm |
| Weight, net / gross | 133 / 155 kg | 133 / 155 kg | 85 / 101 kg |
Supermicro product pages of the three models, read 27 November 2026.
The AS-A126GS-TNBR is the choice for teams that standardise on AMD. It takes two EPYC 9005 or 9004 processors of up to 500 W, up to 384 cores and 768 threads in total, and 24 DIMM slots for up to 6 TB with one module per channel, at 6400 MT/s with the 9005 series and 4800 MT/s with the 9004. The ten 2.5-inch bays split into eight NVMe and two SATA. Its supplies are smaller than those of the Intel model and cover 200 to 240 V. Supermicro prints the same net and gross weight for both chassis. Its December 2025 brochure lists two more 10U B200 systems, the SYS-A22GA-NBRT with Xeon 6900 and the SYS-A21GE-NBRT with 5th or 4th Gen Xeon, and its SuperCluster datasheet for the 10U air-cooled B200 systems (February 2025) places four nodes, 32 GPUs, in one rack.
The SYS-422GS-NBRT-LCC halves the height with direct-to-chip cold plates, which Supermicro credits with up to 87 per cent of the heat; four 80 mm fans remain for the rest. Its description adds "(complete rack and onsite service are required)", and Supermicro states that complete liquid-cooled rack integration is required for purchase. What that means for the room is the subject of our guide to liquid-cooled HGX B200 and B300 servers in 4U.
What to settle in the quote for a SYS-822GS-NBRT
The model page leaves several lines open that decide whether the server runs as planned:
- the eight cluster adapters (ConnectX-7 or BlueField-3, included or added), with transceivers and cables;
- the DPUs for storage and the north-south network, and which slots they occupy;
- the memory: module size, count and the speed the quote assumes;
- the E1.S drives and the M.2 boot pair with its RAID setting;
- the number and type of power connections per supply, against the voltage and outlets at the rack;
- the weight of the configured system and the warranty level.
The software side is short on paper: NVIDIA's CUDA list gives the B200 compute capability 10.0, CUDA 12.8 added compiler support for it, and NVIDIA's notes for the data-centre driver 570.86.15 list the "NVIDIA HGX B200 8-GPU". On an NVSwitch board the driver alone is not enough, and our guide to HGX B200 driver install and Fabric Manager setup lists the packages and checks. On request we pre-install the operating system, drivers, CUDA and a container runtime, with remote setup by our engineering partner Vixen.UNO. Your data-centre staff or the colocation provider rack and connect the server; warranty and service come from Supermicro, handled through us.
For budgeting cards and licences you can request our current NVIDIA price list. Makers side by side are in our comparison of HGX B200 and B300 servers from Supermicro, ASUS and Gigabyte, and the ordering steps in our guide to buying an HGX B200 server.
FAQ
What are the specs of the Supermicro SYS-822GS-NBRT?
Does the Supermicro SYS-822GS-NBRT come with network cards?
How much power does the Supermicro SYS-822GS-NBRT need?
What is the difference between SYS-822GS-NBRT and SYS-822GS-NB3RT?
Is there an AMD version of the Supermicro HGX B200 server?
Where can we buy a Supermicro HGX B200 server in Europe?
We supply the Supermicro SYS-822GS-NBRT and other HGX B200 servers per project. Send us the end user, the installation site, the intended use and the number of servers, and we answer with the open configuration questions. We reply within one business day.
Request a priceWe reply within one business day